When properly installed, this model is
A.D.A.-qualified based on the United
States Access Board’s A.D.A./A.B.A.
Accessibility Guidelines and
the Department of Justice’s
2010 A.D.A. Standards for
Accessible Design.
Available in:
Stainless
(F)
Signature Features
Large Capacity
Large enough to keep several dishes
warm until dinner is ready.
Express-Select® Controls
Easily set temperature or choose
bread proof option.
Adjustable Humidity Control
Keep food moist and delicious until it’s
time to eat.
When properly installed, this model is A.D.A.-qualified based on the
United States Access Board’s A.D.A./A.B.A. Accessibility Guidelines
and the Department of Justice’s 2010 A.D.A. Standards for Accessible
Design.
2
For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.
5-1/4" x 20-1/4" x 17"
Right Bottom Rear
120V / 60 Hz /15A
2
0.5
3.8
15
Yes
60 Lbs.
Warmer Drawer
FGWD3065PF 30" Electric
NOTE: For planning purposes only. Always consult local and national electric codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Connected Load (kW Rating) @ 120 Volts = 0.5 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120V = 3.8 Amps
•
Recommended Circuit Breaker – 15 Amps
Warmer Drawer
FGWD3065PF 30" Electric
•
Always consult local and national electric codes.
•
Full plywood base required, capable of supporting 100 Lbs.
•
Base must be level and cabinet front must be square.
•
Warmer Drawer can be used alone, or is approved to be used in
combination with any Frigidaire® Wall Oven. (Refer to Combination
Installation Specifications and drawing on this page.)
•
Warmer Drawer is approved to be used in combination with any
Frigidaire® Built-In Microwave and /or Electric Single Wall Oven.
To support Wall Oven when using in combination with Warmer
Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base,
capable of supporting 200 Lbs. Do NOT use full base, since planks
are necessary to allow for proper air displacement.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Accessories information available
on the web at frigidaire.com
Specifications
subject to change.
Page 4
Frigidaire 30" Combination Installation –24" Built-In Microwave (with 30" Trim Kit)Electric Single Wall OvenWarmer Drawer
30" Combination Installation
Built-In Microwave / Single Wall Oven / Warmer Drawer
30" Combination Installation Specifications
•
Always consult local and national electric codes.
(Refer to product-specific electrical specifications on this page.)
•
Minimum 23-5/8" deep cutout dimension is critical for proper
combination installation, to ensure that each built-in product’s
faceplate will fit flush against cabinet front.
•
Bases must be level and cabinet front must be square.
•
Minimum 4-1/2" required distance from bottom of Warmer Drawer
cutout to floor.
•
Respect critical dimensions as noted for proper installation of
built-In products.
•
Minimum 21" clearance needed for Wall Oven door depth when open.
30" Built-In Microwave Specifications
•
For built-in installation, microwave MUST be installed with optional
30" Trim Kit which includes Bottom Duct Assembly – shipped in
separate box, ordered by individual part number.
•
Voltage Rating – 120V / 60 Hz / 15 or 20 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.7 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 14.3 Amps
•
Full oven base of solid plywood or similar material required, capable
of supporting 100 Lbs.
•
Minimum 2-7/8" clearance required from bottom of Built-In Microwave
cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap
between both product faceplates.
30" Electric Single Wall Oven Specifications
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
•
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
•
To support Wall Oven when using in combination with Warmer
Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base,
capable of supporting 200 Lbs. Do NOT use full base, since planks
are necessary to allow for proper air displacement.
30" Warmer Drawer Specifications
•
Voltage Rating – 120V / 450W / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.5 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120V = 3.8 Amps
•
Full base of solid plywood or similar material required, capable of
supporting 100 Lbs.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
Specifications
subject to change.
Page 5
Frigidaire 30" Combination Installation –22" Built-In Microwave (with 30" Trim Kit)Electric Single Wall OvenWarmer Drawer
30" Combination Installation
Built-In Microwave / Single Wall Oven / Warmer Drawer
30" Combination Installation Specifications
•
Always consult local and national electric codes.
(Refer to product-specific electrical specifications on this page.)
•
Minimum 23-5/8" deep cutout dimension is critical for proper
combination installation, to ensure that each built-in product’s
faceplate will fit flush against cabinet front.
•
Bases must be level and cabinet front must be square.
•
Minimum 4-1/2" required distance from bottom of Warmer Drawer
cutout to floor.
•
Respect critical dimensions as noted for proper installation of
built-In products.
•
Minimum 21" clearance needed for Wall Oven door depth when open.
30" Built-In Microwave Specifications
•
For built-in installation, microwave MUST be installed with optional
30" Trim Kit which includes Bottom Duct Assembly – shipped in
separate box, ordered by individual part number.
•
Voltage Rating – 120V / 60 Hz / 15 or 20 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.55 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 13 Amps
•
Full oven base of solid plywood or similar material required, capable
of supporting 100 Lbs.
•
Minimum 2-7/8" clearance required from bottom of Built-In Microwave
cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap
between both product faceplates.
30" Electric Single Wall Oven Specifications
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
•
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
•
To support Wall Oven when using in combination with Warmer
Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base,
capable of supporting 200 Lbs. Do NOT use full base, since planks
are necessary to allow for proper air displacement.
30" Warmer Drawer Specifications
•
Voltage Rating – 120V / 450W / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.5 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120V = 3.8 Amps
•
Full base of solid plywood or similar material required, capable of
supporting 100 Lbs.
Note: For planning purposes only. Refer to Product Installation Guide