Friedrich WS10D10B User Manual

Wallmaster® Thru-the-wall
Height Widt h Depth
Height
of Front
Widt h of
Front
Depth
with
Front
Minimum
Extension Into Ro om
with Fr ont
Chassis 15 3/4" 26 1/2" 16 1/4" 17 1/4" 27 1/2" 23 1/4" 7 1/2"
Model
Height Width Depth
Depth
with
Front
Minimum
Extension
Outside
Thru-the-wall
Finished Hole
Height Width Max. Depth
WSE Sleeve 16 3/4" 27" 16 3/4" 24 1/4" 9/16" 17 1/4" 27 1/4" 15 5/16"
Air Conditioners, Heat Pumps & Electric Heat models
PURCHASER P.O. # DATE
PROJECT LOCATION
ENGINEER ARCHITECT
SUBMITTED BY FOR APPROVAL FOR REFERENCE
Comfort & Convenience
New design makes controls more
accessible
Remote control
24-hour timer
Smart Fan auto-adjusts fan speed to
maintain desired temperature
Check filter reminder
3-speed fan
Auto restart
Electronic defrost control
Individually adjustable louvers direct air
flow where you need it
Washable, antimicrobial filter
Energy Savings
• Money Saver® setting cycles the fan
with the compressor
ENERGY STAR® qualified models
R-410A refrigerant
Durability & Quality
Rotary compressor provides quiet,
dependable performance
Premium aluminum exterior grille
Dense blower insulation blocks
outdoor noise
Rifled copper tubing
Impact resistant front cover
High tech fins with sine wave
lanced louvers increase energy efficiency by increasing surface area for heat exchange
Installation Features
• Mounts flush with the exterior wall for a neat appearance
• Ideal for thicker wall installations, where side fins don’t fit
• A high efficiency replacement for 27” sleeves including Fedders A and B*.
Sleeve measures 27” W x 16 3/4” H
Accessories
AG architectural grille for use with
WSE sleeve
Drain kit for condensate disposal
Internal drain kit for new
construction applications where condensate drain system is built-in
WSE sleeve ships with inside and outside steel weather panels and standard exterior grille.
Baffle adapter kit for use with deep sleeve installations (Fedders B sleeves).
CHASSIS DIMENSIONS
WSE SLEEVE DIMENSIONS
FITS EXISTING FEDDERS SLEEVES.
Sleeve Dimensions
Height (inches) 16 3/4 16 3/4 16 3/4
Width (inches) 27 27 27
Depth (inches) 16 3/4 16 3/4 19 3/4
Friedrich
WSE Sleeve
Fedders A Sleeve
Fedders
B Sleeve
Thru-the-wall_WallMaster_Submittal_2016
Chassis requires WSE sleeve (sold and shipped separately)
SPECIFICATIONS
ENERGY STAR® models
Model Cooling Btu Heating Btu
WS08D10A
WS12D10A
8000
12000
WS15D30A 14500/14000
INDOOR COOLING
Model
WS08D10A
WS12D10A
WS15D30A
0$; +,*+ 0(' /2:
55.3 53.5 52.0 NA 61.5 59.2 58.0 NA 55.1 53.3 52.1 NA 61.5 59.1 57.1 NA
62.1 56.0 51.1 NA 67.1 60.8 56.6 NA 62.1 56.0 51.1 NA 57.1 61.7 67.9 NA
58.5 55.9 50.9 NA 66.8 63.4 60.6 NA 58.0 55.2 49.0 NA 66.6 62.8 57.0 NA
NA
NA
NA
Volts
Rated
230/208 7.0/7.6 1559/1505
PLUG FACE/CIRCUIT RATING
Cooling
Amps
Cooling
Watts EER CEER
115 6.3 748
115 10.8 1224
A-WEIGHTED SOUND PRESSURE LEVEL (dbA)
OUTDOOR COOLING 0$; +,*+ 0(' /2:
Estimated
Yearly
Energy
Cost
10.7 10.6 $67
9.8 9.7 $110
9.3/9.3
9.3/9.3 $140
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.
INDOOR FAN ONLY 0$; +,*+ 0(' /2:
OUTDOOR FAN ONLY 0$; +,*+ 0(' /2:
Tested in Friedrich DDC sound test lab.
Circuit
WallMaster Model Number
WS08D10A, WS12
WS1
Power cords are located on front left of WallMaster models.
Due to continuing research in new energy-saving technology, specic ations are subject to change without notice.
As an models meet the Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
®
0A.
5D3
ENERGY STAR
ENERGY STAR
D10A
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR®
®
guidelines for energy efciency.
Rating
Breaker
or T-D Fuse
125V - 15A 5 - 15P 6
250V - 15A 6 - 15P 6
Plug Face
(NEMA#)
Power
Cord
Length
(ft.)
Wall
Outlet
Appearance
Model
WallMaster
WSE Sleeve 18" 27 1/4" 18"
Chassis 19 3/ 8" 30 5/8" 27 1/2"
®
Carton Dimensions
INCHES
Height Wid t h Depth
Thru-the-wall_WallMaster_Submittal_2016
Loading...