Friedrich WE16B33A, WE13B33A, WE13B33B, WE10B33A, WE16B33C Installation And Operation Manual

...
Thru-the-wall
Temp/Hour
Money
Saver
®
Fan
Only
Clock
Start Time
Stop Time
Power
Fan
Speed
Mode
P
M
Timer
On/Off
Set
Hour
72
Air Conditioners and Heat Pumps
115-Volt: WS08, WS10, WS14 230-Volt: WS10, WS13, WS16, WE10, WE13, WE16, WY10, WY13
Installation and Operation Manual
920- 007-13 (12-07)
920-007-13
Table of Contents
Introduction
Economizing Tips ............................................................................................................................................................................................................................3
Electrical Data ..................................................................................................................................................................................................................................3
Introduction
How to operate your Friedrich room air conditioner .......................................................................................................................................................................4
To start unit .......................................................................................................................................................................................................................................4
To set mode of operation ..................................................................................................................................................................................................................4
To adjust temperature ......................................................................................................................................................................................................................4
To adjust fan speed........................................................................................................................................................................................................................... 4
To activate smart fan ........................................................................................................................................................................................................................ 4
To set hour clock ............................................................................................................................................................................................................................... 4
To set the timer .................................................................................................................................................................................................................................4
Automatic component protection ..................................................................................................................................................................................................... 5
Using the remote control .................................................................................................................................................................................................................. 5
How to clean the air lter .................................................................................................................................................................................................................6
How to change airow direction .......................................................................................................................................................................................................7
How to cover inner weather panel holes ......................................................................................................................................................................................... 7
Electrical requirements .................................................................................................................................................................................................................... 7
Never use an extension cord ...........................................................................................................................................................................................................8
Power cord information ....................................................................................................................................................................................................................8
Troubleshooting tips and home maintenance .................................................................................................................................................................................. 9
Installation instructions for WSC sleeve
Mounting hardware ........................................................................................................................................................................................................................10
Wall preparation .............................................................................................................................................................................................................................10
Installation requirements .................................................................................................................................................................................................................11
Sleeve installation ............................................................................................................................................................................................................................11
WallMaster chassis installation instructions
WS, WE and WY models (WSC-A sleeve) ins tall ation ....................................................................................................................................................................... 12
WS, WE and WY models (WSC-B sleeve) installation .......................................................................................................................................................................13
Condensate removal ...................................................................................................................................................................................................................... 15
Alternate drain kits .......................................................................................................................................................................................................................... 15
Warranty .........................................................................................................................................................................................................................................16
Warranty registration record ...........................................................................................................................................................................................................17
2
920-007-13
WELCOME to years of economical comfort
Your new Friedrich Room Air Conditioner has been carefully engineered and manufactured to give you many years of dependable,
efcient operation, keeping your room at a comfortable temperature
and humidity level. Many extra features have been built into your Friedrich Room Air Conditioner to assure quiet operation, greatest
circulation of cool, dry air, most exible selection of function controls,
and high economy of operation.
There are many things you can do in and around your home to save
more money - and even increase the efciency and long life of your
Friedrich unit. Here are a few examples:
1. How to Set Thermostat: When you rst turn on your air
conditioner, select the highest fan speed and set the thermostat to its coldest position to cool the room. When the desired temperature is reached, turn the thermostat control toward "warmer" until the compressor goes off. The thermostat will then cause the compressor to go on and off to maintain this selected temperature. You can adjust the fan speed for optimum air circulation.
2. Do not block the ow of air to and from the unit - make sure the
louvers are directed to give even distribution of air throughout
the room. Caution: If air is obstructed and/or deected back
into the air conditioner, this may cause the unit to cycle on and off rapidly, which could damage your unit.
3. Adequate insulation - walls, ceilings, and below oors - can save
up to 50% of the cost of cooling in most areas of the country.
4. Caulking: in well insulated homes, air leaks around doors,
windows, lighting and plumbing xtures can account for as
much as 30% of the load on heating and cooling systems. See that all these areas are well caulked.
6. Have a replace? Be sure the damper is closed during air
conditioner operation.
7. When it’s time to reroof or repaint the outside of your home,
choose light colors. They reect heat instead of absorbing it.
8. Shade your outside walls (especially on the west) from the direct sun; most importantly, shade the unit itself Trees and shrubs provide natural shading, but make sure they don’t block the air
ow around the unit. If natural shade isn’t present, awnings are
the best solution for shading the unit and the windows. Also, avoid areas where too much dust or pollen would be drawn into the air conditioner.
9. Inside the house, use blinds, screens, or drapes on windows exposed to the sun. They will reduce your cooling needs. (Lined or insulated draperies will also help cut heating costs in winter).
10. Make sure your attic area is properly vented. In addition, consider installing turbine or power ventilators to help remove hot air from your attic.
11. Keep your Friedrich unit clean. Use a vacuum cleaner attachment for accessible parts, but take care not to damage
them. Clean the reusable lter at least twice a month.
12. Set the thermostat at a higher temperature - save 5% in energy usage for each degree of temperature over 72°F.
These are the most important suggestions for saving money on cooling costs. Some, however, may not be applicable to your house or area. Check with your local utility company for more specialized information.
5. Install weather stripping (metal is preferable to felt) around exterior doors and windows.
Electrical Data
Model Plug Type
WS08, WS10, WS14 NEMA No. 5-15P 125V-15 AMP
WS10, WS13, WS16 NEMA No. 6-15P 250V-15 AMP
WE10, WE13, WE16, WY10, WY13
NEMA No. 6-20P 250V-20 AMP
Circuit Rating, Breaker
or Time Delay Fuse
3
920-007-13
How to operate your Friedrich room air conditioner
To start unit
If your air conditioner is installed and plugged into a proper receptacle,
it is ready to go. The rst time the unit is started, the compressor will
delay for three minutes. See Automatic Component Protection on the following page.
1
Touch the Power button once. The unit will automatically be in Cool mode with the temperature set at 75°F (24°C) and the fan speed at F1, the sleep setting.
To set mode of operation
When you rst turn the unit on, it will be in the Cool mode with con- stant fan.
2
On WS cool-only models, touch the Mode buton once to activate the MoneySaver instructions on WY/WE models).
MoneySaver
sor so that the fan does not run all the time. This saves energy
and improves dehumidication. MoneySaver® wi ll al so run to t es t
the temperature if the off cycle is too long. Or you may prefer constant fan for more air movement. (To return to constant fan, touch the Mode button two more times).
In order to run the fan by itself, do the following:
®
(WS models only. See item 14 for Money Saver
®
is a feature that cycles the fan with the compres-
To activate Smart Fan (WY/WE heat-cool models)
9
Press the Smart Fan button to activate the Smart Fan. The light
will indicate that this feature is in use.
Smart Fan will adjust the fan speed automatically to maintain the desired comfort level. For example, if the outside doors in your home are opened for an extended period of time, or more people enter a room, Smart Fan may adjust to a higher fan speed to compensate for the increased heat load. This keeps you from having to adjust the fan speed on your own.
To set the hour clock
10
Touch the Set Hour button to see the current setting. The
number that is displayed is the approximate time (hour only). Use the TO SET A.M. AND P.M. ACCORDINGLY. (P.M. is indicated by a red light in the upper left corner of the display).
and buttons to change the settings. BE SURE
To set the timer
NOTE: Set the HOUR CLOCK (Set Hour) before attempting to set timer functions.
You can set the Start Time and Stop Time a minimum of one hour
apart, and a maximum of 23 hours apart.
On WY/WS heat-cool models, touch the Mode button once to
activate the Fan Only feature. The Fan Only setting will circulate air in the room without the compressor coming on.
3
Continuing from MoneySaver once to activate the Fan Only feature (WS cool-only models).
®
mode, touch the Mode button
To adjust temperature
4
Use the Mode b utto n to s elec t eit her t he Cool or MoneySaver
function (or Heat for WY/WE heat-cool models)
5
COOLER – Touch the
6
WARMER – Touch the
7
Press both the
the temperature from Fahrenheit (°F) to Celsius (°C). Repeat Step 7 to switch from °C back to °F.
button to lower the room air temperature.
b ut t on to ra i se th e r o om ai r t em p er at ur e.
and buttons at the same time to switch
To adjust fan speed
8
Touch the Fan Speed button to see the current setting. Touch
it again to change speed. F1 is the lowest setting (SLEEP SETTING / LOW), F2 is MEDIUM, and F3 is HIGH.
To activate Smart Fan (WS cool-only models)
9
There is a fourth option, SF, w hen se lec ti ng t he fan sp eed. Thi s i s
the SMART FAN function. SMART FAN DOES NOT OPERATE IN CONJUNCTION WITH THE FAN ONLY MODE.
4
11
After setting the time, press the Set Hour button once (Start
light on). Use the
unit will STA RT.
12
After selecting the St ar t Tim e, press the Set Hour button once.
(Stop Light on). Use the that the unit will STOP. After selecting the stopping time, press the Set Hour button once.
®
13
Press the Timer On/Off button (light turns on) to activate the
timer function. To deactivate this function, press the Timer On/ Off button once again (light turns off). Once the on and off times have been selected, they will remain in memory and cycle daily until changed.
NOTE: If the unit is unplugged or the power is interrupted, the HOUR must be reset or the Timer On/Off will not function when desired.
and buttons to select the time that the
and
buttons to select the time
To Activate Money Saver (WY/WE models)
14
Press the Money Saver button to activate the Money Saver
feature. The light will indicate the Money Saver is in use.
®
MoneySaver
sor so that the fan does not run all the time. This saves energy
and improves dehumidication. MoneySaver® wi ll al so run to t es t
the temperature if the off cycle is too long. Or you may prefer constant fan for more air movement. (To return to constant fan, touch the Mode button two more times).
is a feature that cycles the fan with the compres-
920-007-13
Temp/Hour
Cool
Money Saver
®
Fan Only
Clock
Start Time
Stop Time
Power
Fan
Speed
Mode
PM
Timer
On/Off
Set
Hour
72
2 3
4
8
9
10 11 12
13
1
6
5
7
2 3
4
10 11 12
14
1
6
5
7
9
8
13
Temp/Hour
Power
PM
Cool
Fan Only
Heat
Clock
Start Time
Stop Time
Smart Fan
Fan
Speed
Mode
Timer
On/Off
Money
Saver
Set
Hour
72
Figure 1: WS Model cool-only control panel Figure 2: WY/WE Model heat-cool control panel
Automatic component protection
Your unit is equipped with Automatic Component Protection.
To protect the compressor of the unit, there is a three minute delay if you turn the unit off or if power is interrupted. The fan will not be affected. Also, if you switch from Cool mode to Fan Only mode, and switch back to Cool mode, there is a three-minute delay before the compressor comes back on.
Using the remote control
To start unit
1
PO WE R - Pr ess t he Power button once. The unit will automatically start in the mode and fan speed it was last left on.
To set mode of operation
2
COO L - Pr ess t he Cool button to automatically switch the operat- ing mode to COOL.
3
FAN ONLY - Press the Fan Only button if you want to run the fan only.
4
HEAT (WY/WE models only) - Press the Heat button to automatically switch the operating mode to HEAT.
5
MoneySaver
the MoneySaver® feature. This feature cycles the fan with the compressor so that the fan does not run all the time.
®
- Press the Money Saver
®
button to activate
To adjust temperature
6
WARMER - Press the
7
COOLER - Press the
Warmer button to raise the temperature setting.
Cooler button to lower the temperature setting.
To adjust fan speed
8
FAN SPEED - Press the Fan Speed button to see the current setting. Press again to change the fan speed. F1 is the lowest setting (SLEEP / LOW), F2 is MEDIUM, F3 is HIGH, and SF is the SMART FAN setting.
To set the hour clock
9
SET HOUR CLOCK - Press the Set Hr. button once to see the current clock setting. Continue pressing the button until you arrive at the current time (Hour only). Minutes are not shown on the display. Make sure that the A.M. / P.M. setting is correct.
5
Temp/Hour
C o
o
l M o
n e y
S
a
v
e r
®
Fan Only
C lo
c
k S ta
r t T
im
e
S to
p T im
e
Power
Fan
Speed
M
ode
PM
Tim
er
On /Of
f
S et
H our
72
Filter
Intake Grille
To set the timer
Money
Fan
Timer Operation
Set Hr.
Stop
Start
Temperature
Fan
Cool
On/Off
Power
Cooler
Only Speed Saver
®
Warmer
9
11
8
12
10
53
1
2
67
Heat
4
NOTE: You can set the START and STOP times a minimum of one hour apart, and a maximum of 23 hours apart.
10
TI MER S TART - Pr ess Start to vi ew the cur ren t st art t ime fo r coo l- ing. Continue pressing the START button until you arrive at the start time you desire. The start time for cooling will then be set.
11
TIMER STOP - Press the Stop button. Continue pressing the STOP button until you arrive at the stop time you desire. The stop time for cooling will then be set.
12
TIMER ON / OFF - Press the On/Off button (under Timer Operation) to activate (light on) or deactivate (light off) the timer.
Once the on and off times have been selected, they will remain in memory and cycle daily until changed.
NOTE: If the unit is unplugged or the power is interrupted, the Set Hr. function must be reset or the Timer On/Off function will not work.
920-007-13
Figure 3: WY/WE heat-cool model remote control
Additional RC1 wireless remote controls can be purchased from your Friedrich dealer.
How to clean the air filter
Your Friedrich room air conditioner is equipped with a Permafoam
reusable air lter which is not affected by washing. The lter serves to
remove dust, pollen, and other impurities from the air.
KEEP THE FILTER CLEAN - A clogged, dirty lter will reduce the operating efciency of your unit and contribute to frosting of the indoor coil. Be sure to check the lter every 7 to 10 days. The lter
check procedure is easy, due to the unique design of the Friedrich DECORATIVE FRONT.
FILTER ACCESS - Remove the INTAKE GRILLE from the DECORATIVE FRONT frame by grasping it at the upper right and left side corners. Pull out until the GRILLE is released from the upper retaining snaps. Tilt down toward you, lift up and out of the bottom
retaining snaps. This will expose the lter. Remove the lter by pulling it toward you. Wash the lter in hot, soapy water, rinse, squeeze lightly
to remove excess water, shake dry - do not twist - and replace in the unit on the two support hangers. Replace the INTAKE GRILLE by positioning the bottom of the GRILLE into the bottom retaining snaps. Tilt the front up and away from you. Press in lightly on top and the GRILLE will position itself into the upper retaining snaps.
Figure 4
6
920-007-13
Return
A
ir Grille
Decorative Front
WSC Sleeve
AB123456C3
567
MODEL# WS07A10B
Airflow
Rotate
Discharge Grille
1"
Diameter
1" Diameter Plug
1
1
1
2
2
2
How to change airflow direction
The DISCHARGE GRILLE is installed at the factory to provide 45˚ upward airow into the room. (Direction 1 in Figure 5). If a vertical airow is desired (Direction 2), the direction can be changed by rotating
the DISCHARGE GRILLE.
Unplug the air conditioner.
Remove the DISCHARGE GRILLE RETAINER attached with one screw in the right side of the grille.
Remove the DISCHARGE GRILLE from the retaining slots near the CONTROLS, and rotate the grille as shown in Figure 5.
Reinstall the DISCHARGE GRILLE by placing it in its retaining slots. Reattach the DISCHARGE GRILLE RETAINER with the retaining screw. The unit is now ready to operate.
How to cover inner weather panel holes
Two beige plugs are included in the plastic bag taped to the WallMaster chassis. These plugs may be used to cover the two holes left after removing the inner weather panel (see Figure 5). The plugs must be attached before the DECORATIVE FRONT frame is installed.
Electrical requirements
I MP OR TAN T: Before you begin the actual installation of your air conditioner, check local electrical codes and the information below.
Your air conditioner must be connected to a power supply with the same AC voltage and hertz rating as marked on the nameplate located on the chassis. Only alternating current (AC) can be used. Consult pages 3 and 7 for the correct type of receptacle for your model.
An overloaded circuit will invariably cause malfunction or failure of an air conditioner, therefore, it is extremely important that the electrical power and the wiring is adequate. Consult your dealer or power company if in doubt.
CIRCUIT PROTECTION - Before installing or relocating your Friedrich Room Air Conditioner, check the amp rating of the circuit breaker or "TIME-DELAY" fuse. Refer to the nameplate located on the air conditioner chassis to determine the correct fuse or circuit breaker amperage for your model. The rating MUST NOT exceed the value stated on the nameplate. If the air conditioner is connected to a circuit protected by a fuse, a "TIME-DELAY" fuse must be used due to the momentary high current demands when your air conditioner is started.
Figure 5
7
TEST
RESET
WARNING
TEST BEFORE EACH USE
1. PRESS RESET BUTTON
2. PLUG LDCI INTO POWER RECEPTACLE
3. PRESS TEST BUTTON, RESET BUTTON SHOULD POP UP
4. PRESS TEST BUTTON, FOR USE DO NOT USE IF ABOVE TEST FAILS
WHEN GREEN LIGHT IS ON IT IS WORKING PROPERLY
RESET
TEST
Never use an extension cord
Your Friedrich room air conditioner is equipped with a three-prong (grounded) plug for your protection against shock hazards and should be plugged directly into a properly grounded three-prong receptacle. If you have a two-prong receptacle you will need to have the circuit
replaced by a certied electrician with a grounded circuit that meets
all national and local codes and ordinances. Under no circumstances should you remove the ground prong from the plug. You must use the three-prong plug furnished with the air conditioner.
NEVER CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.
Power cord information
All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device meets the UL and NEC requirements for cord connected air conditioners effective August 2004.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
920-007-13
Once plugged in the unit will operate normally without the need to reset the LCDI device.
If the device fails to trip when tested or if the power supply cord is damaged it must be replaced with a new supply cord from the manufacturer. We recommend you contact our Technical Assistance Line at (800) 541-6645 ext. 662. To expedite service, please have your model and serial number available.
NOTE: Your LCDI device will resemble one of these illustrations.
2. Press RESET (See Figure 6).
3. Press TEST (listen for click; Reset button trips and pops
out).
4. Press and release RESET (listen for click; Reset button
latches and remains in). The power supply cord is ready for operation.
NOTE: LCDI device is not intended to be used as a switch.
Figure 6
8
920-007-13
Troubleshooting tips and home maintenance
Won’t cool
If the unit operates, but won’t cool, determine if the controls are
properly set. Wait three minutes before setting the thermostat to a
cooler position in order to check control settings. Check the lter and
clean it thoroughly, if needed. Check to see if the vent door is closed. Check to see if the chassis seal gasket is properly installed (refer to
page 14 for seal gasket installation).
Won’t heat (for heat/cool models only)
If the unit operates, but won’t heat, determine if the control settings are correct. Adjust the thermostat to a warmer position to determine if it
operates. Also, check the lter and clean it thoroughly, if needed.
Odors in heating (for heat/cool models only)
You may notice a smoke odor the rst time the heater element comes on. This is common in any type of heat system when rst turned on
for the winter. The odor comes from dust and other particles that
accumulate during the warm months. The odor will dissipate quickly.
Won’t run
If the unit fails to operate, check to see if the power cord is rmly
plugged in. Check for blown fuses, tripped circuit breakers or a
tripped LCDI Device (Refer to LCDI reset instructions in the Power cord information section). Restore the circuit breaker or replace the
blown fuse with a proper size "TIME-DELAY" fuse. The proper fuse size is shown on pages 4 and 7 in these instructions. After restoring the current supply to the unit, wait three minutes before restarting.
Frosting of the indoor coil
Certain operating conditions may produce indoor coil frost. During
the cooling operation, a dirty lter or restricted air distribution in
combination with cool, damp weather could cause such an occurrence. Should the indoor coil frost over while cooling, set the control to FAN and keep it running until the frost on the coil is gone. Setting the thermostat to a slightly warmer position will probably keep the coil
from frosting over again.
Cleaning the decorative front
The decorative front of your Friedrich room air conditioner, as well as the complete cabinet, may be cleaned with warm water and mild detergent. Under adverse operating conditions, the indoor and outdoor
coils and base pan may require periodic cleaning to maintain efcient
operation. Your Friedrich dealer should be called when this service is required.
Things to know about a WallMaster heat pump
During the heat pump operation, you may notice some functions that did not occur when the unit was used for cooling:
1. It is common for ice to form on the outdoor coil of your WallMaster Heat Pump. The ice forms due to moisture in the outdoor air passing over cold (below freezing) coil surfaces.
2. When the outdoor coil forms ice, your heat pump will automatically initiate a defrost. The compressor will stop and the fan will continue to run. The electric heat will be turned on to continue warming the room while the outdoor air defrosts the outdoor coil. After the defrost is completed, the unit will automatically return to the heat pump mode.
3. It is normal for vapor (steam) to rise from the outdoor coil during the defrost. This is similar to expelling warm breath on a cold morning.
4. If the outdoor temperature drops below 43°F during heat pump operation, your WallMaster Heat Pump will automatically switch to electric resistance heat and will continue to operate in this mode as long as the outdoor temperature remains at
43°F or below.
9
920-007-13
Installation instructions for WSC sleeve
Mounting hardware provided
ITEM NO. DESCRIPTION QTY.
1 SCREW, #12A x 2" 5
Wall preparation
STEP 1 The wall opening required for a WSC SLEEVE is 17 ¼"
high by 27 ¼" wide.
A. Adjustable SUBBASE (SB) or other unit support must be provided
for panel wall type construction and for walls less than 8" thick.
STEP 2 LINTELS must be used in opening of brick veneer and
masonry walls to support the material above the WSC SL EEVE. Th e following c onsideratio ns sh ould also b e giv en:
Minimum Of 24" Required
From Top Of Unit To Ceiling.
Inside Wall
Minimum Of 1" Spacing
Required On All Sides
Of The Unit.
B. A minimum distance of 1" must be allowed on all sides of the unit
to adjacent wall and oor. Where the subbase is required, the minimum distance from the oor to the sleeve must be 3 ½". To
minimize chances of short cycling of the compressor, the minimum clearance between the ceiling and the top of the unit should be 24". (See Figure 8).
Figure 7
Lintels
WSC Sleeve
10
1" Minimum 3 ½" For Subbase
⅞" Minimum Beyond Inside
Wall
Drain Extension
9
⁄16" Minimum
Beyond Outside
Wall
Outside Wall
Installation requirements
920-007-13
STEP 1 The WSC SLEEVE should be positioned so that the
DRAIN EXTENSION extends a minimum of
9
" beyond
16
the OUTSIDE WALL (See Figure 7).
STEP 2 The WSC SLEEVE must extend a minimum of ⅞" beyond
the INSIDE WALL.
STEP 3 The WSC SLEEVE must be installed level side to side.
STEP 4 The WSC SLEEVE must also be installed with a downward
tilt toward the outside of the building. If a level is placed so that it rests on the FRONT and BACK UNIT REST as
shown in Figure 8, a properly installed unit provides a ½
bubble slope to the outside of the building.
CAUTION: SLEEVE projections and leveling precautions
must be observed to prevent the entry of water into the room.
Figure 8
Raised Ledge
Level
Front Unit Rest
Sleeve installation
STEP 1 After unpacking the WSC SLEEVE from the carton, remove
the corrugated FRONT PANEL. Place the WSC SLEEVE in the wall opening following the instructions given in the INSTALLATION REQUIREMENTS. Attach the SLEEVE to the INSIDE WALL by driving two #12A x 2" screws in each side of the SLEEVE (see Figure 7). Shim at the top of the SLEEVE, midway between the sides. Drive one #12A x 2" screw in the top of the sleeve, close to the shim. Install screws from inside the SLEEVE. If the wall opening is not
framed with wood, use expansion anchor bolts or molly
(toggle) bolts (not provided).
Back Unit Rest
STEP 2 Once the SLEEVE has been installed, check the LEVEL
again to be sure the ½ bubble downward tilt is maintained.
Apply shims, if required, to maintain the proper slope.
STEP 3 Caulk the perimeter of the entire opening on the inside and
the outside between the SLEEVE and the WALL.
STEP 4 The corrugated front panel removed in Step 1 above must
be remounted back in place if masonry work is to be done and/or if the "WallMaster" CHASSIS is to be installed at a later date.
11
920-007-13
AB123456C3567
MODEL# WS07A10B
Condenser Shroud
REMOVE
WallMaster chassis installation instructions for WS, WE and WY models (WSC-A sleeve)
These instructions are provided for installation of WallMaster air
conditioner chassis models into thru-the-wall sleeves. This chassis has been UL approved with the sleeve listed on the serial nameplate of this chassis. Important warranty information is provided on pages
17 and 18. Keep these instructions in a convenient location for any
warranty service that may be required.
STEP 1 Check the sleeve to be certain it has been correctly installed
in the wall. Remove the corrugated front panel on the WSC SLEEVE. Remove the rear WEATHER PANEL. Reverse grille. Place lower edge into sleeve tab (Friedrich logo facing out). Align slots with screw holes. Secure grille with screws.
A. Check the anchor screws. There should be four
(4) in the WSC SLEEVE (two in each side).
B. Determine if the sleeve has a downward slope,
to the outside, of ½ bubble on a level. See
page 10 for further details.
C. Check to be sure the sleeve has been sealed
around all edges with an industrial type caulking on both the outside and inside to prevent rain entry.
D. A sleeve sealing gasket has been provided
in the chassis shipping carton. Remove it from the carton, peel the protective coating from the adhesive, and install it in the sleeve (adhesive down).
STEP 2 Check the electrical receptacle to see that it conforms to
the requirements for the chassis model to be installed. See pages 2 and 5, for the receptacle requirements.
STEP 3 The decorative front is packaged in a separate box inside
the chassis shipping carton, between the chassis and the carton. Remove this box and set the box aside until later.
STEP 4 With the help of an assistant, remove the chassis from
the shipping carton. Be careful not to allow anything to impact against the hairpins as this may result in damage to them. With the help of an assistant, lift the chassis by the basepan and slide it into the sleeve until it contacts the rear grille. With the chassis in proper position, the front edge of the basepan must extend out 4 ¾ inches from the front (side) edge of sleeve.
12
Figure 9
920-007-13
WallMaster chassis installation instructions for WS, WE and WY models (WSC-B sleeve)
These instructions are provided for installation of WallMaster air conditioner chassis models into thru-the-wall sleeves. This chassis
has been UL approved with the sleeve listed on the serial nameplate of this chassis. Important warranty information is provided on pages 17 and 18. Keep these instructions in a convenient location for any warranty service that may be required.
STEP 1 Check the sleeve to be certain it has been correctly installed
in the wall. Remove the corrugated front panel on the WSC SLEEVE. Remove the rear WEATHER PANEL. Place lower edge into sleeve tab (Friedrich logo facing out). Align slots with screw holes. Secure grille with screws.
A. Check the anchor screws. There should be four
(4) in the WSC SLEEVE (two in each side).
B. Determine if the sleeve has a downward slope,
to the outside, of ½ bubble on a level. See
page 10 for further details.
C. Check to be sure the sleeve has been sealed
around all edges with an industrial type caulking on both the outside and inside to prevent rain entry.
D. A sleeve sealing gasket has been provided
in the chassis shipping carton. Remove it from the carton, peel the protective coating from the adhesive, and install it in the sleeve (adhesive down).
STEP 2 Check the electrical receptacle to see that it conforms to
the requirements for the chassis model to be installed. See pages 2 and 5, for the receptacle requirements.
STEP 3 The decorative front is packaged in a separate box inside
the chassis shipping carton, between the chassis and the carton. Remove this box and set the box aside until later.
STEP 4 With the help of an assistant, remove the chassis from
the shipping carton. Be careful not to allow anything to impact against the hairpins as this may result in damage to them. With the help of an assistant, lift the chassis by the basepan and slide it into the sleeve until it contacts the rear grille. With the chassis in proper position, the front edge of the basepan must extend out 4 ¾ inches from the front (side) edge of sleeve.
Rear weather panel
Figure 10
13
920-007-13
Return Air
Grille
Decorative Front
Screws (4)
Chassis Seal
Gasket
AB123456C3567
MODEL# WS07A10B
STEP 5 CHASSIS SEAL GASKET INSTALLATION: After
installing the shell, slide the chassis into the shell stopping approximately 3" from full insertion. Stuff the chassis seal gasket one inch deep between the chassis and the shell (see Figure 11). Make sure the gasket is installed beginning from the lower right side corner and extending over the top and down to the lower left side corner. Then push the chassis all the way into the shell for the remaining distance so that the plastic front meets the front edge of the shell.
If chassis seal gasket is not installed, the operation of the
unit will be negatively affected. Also, the operation noise
and outside noise will be amplied.
STEP 6 Remove the intake grille from the decorative front frame by
grasping it at the upper right and left side corners. Pull out until the grille is released from the upper retaining snaps.
Tilt it down toward you, lift up and out of the bottom retaining
snaps. Install the decorative front frame in place over the sleeve opening and attach it to the chassis with four sheet metal screws as shown in Figure 11. Replace the intake grille by positioning the bottom of the grille into the bottom retaining snaps. Tilt the front up and away from you. Press in lightly on top, and the grille will position itself into upper retaining snaps.
Figure 11
14
Attach the frame to the chassis by installing four (4) 8A-5/8" screws through the slots in the frame and into the holes in the chassis.
920-007-13
Basepan
Drain hose
Drain nipple
Sleeve
Condensate removal (WS, WE and WY models)
If you desire to drain condensate from the basepan during unit operation, this unit is provided with a drain nipple that can be attached to the basepan. You must provide a 3/8" outside diameter thin-wall plastic or copper tube which will attach to the drain nipple. Follow the instructions below:
STEP 1 Find the drain plate on the rear of the basepan and
remove it. (See Figure 12).
STEP 2 Remove the knockout in the lower right side of the rear
grille. Slide the chassis into the WSC SLEEVE so that the drain nipple extends through the knockout.
STEP 3 Slide the tubing inside the drain nipple.
If the chassis must be removed from the sleeve for service, remove the clamped drain hose before sliding the chassis out of the sleeve.
Figure 12
Alternate drain kits
DK (Drain Kit)
In the event that the outdoor temperature drops below 37°F, any water that remains in the chassis basepan is drained into the sleeve pan on WE and WY models to prevent freezing. (NOTE: In the cooling mode
of the WS, WE and WY models, condensate overow is possible in
very humid climates). For these particular instances, an optional drain kit (Accessory #DK) is available for water removal.
IDK (Interior Drain Kit)
New construction allowing for condensate drain systems built within the walls can use the Friedrich Interior Drain Kit (Accessory #IDK) designed for installation in the bottom of the sleeve below the condensate bellows valve (heat/cool models only).
15
920-007-13
Friedrich Air Conditioning Company
P.O. Box 1540
San Antonio, TX 78295
210.357.4400
www.friedrich.com
WALLMASTER
£
THRU-THE-WALL AIR CONDITIONERS
LIMITED WARRANTY
FIRST YEAR
ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from
date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within twelve months from the date of the original purchase.
SECOND THROUGH FIFTH YEAR
SEALED REFRIGERANT SYSTEM: If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser
coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.
APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District of Columbia, and Canada. This warranty is not applicable to:
1. Air filters or fuses.
2. Products on which the model and serial numbers have been removed.
3. Products which have defects or damage which results from improper installation, wiring, electrical current characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service Organization in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write
to: Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540.
LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.
NOTE: Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of
consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.
OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services.
All service calls for explaining the operation of this product will be the sole responsibility of the consumer.
All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to repairs being made.
(10-04)
16
920-007-13
Friedrich wants you to remain pleased with your Room Air Conditioner. Should further assistance be needed concerning this warranty, contact:
RAC Warranty, Service and Parts
Friedrich Air Conditioning Co.
P.O. Box 1540
San Antonio, TX 78295-1540
Your personal warranty registration record
WARRANTY REGISTRATION: Please complete and return your Warranty Registration Card (not this
form) immediately and mail to FRIEDRICH. While it is not required that you do so in order to obtain warranty performance, it registers your warranty, making it easier and faster to verify the period of your warranty cover­age and to contact you, should field service and/or product recall ever become necessary.
Or register on line at www.friedrich.com (U.S.A. Only).
FOR YOUR RECORDS: FILL IN THE FOLLOWING INFORMATION WHEN UNIT IS INSTALLED, SO IT WILL BE READILY AVAILABLE IF NEEDED LATER.
Model No. Serial No. Date Installed
Bought from:
USE OF NON-FRIEDRICH PARTS COULD VOID YOUR WARRANTY
(Dealer name)
(Dealer Address)
(Phone)
(Person to contact)
ALWAYS USE FRIEDRICH FACTORY AUTHORIZED PARTS.
17
Loading...