TECHNICIAN’S QUICK REFERENCE GUIDE -
HIGH-CAPACITY MEAT FREEZER (HCMF) – 30”
DOCUMENT PART NUMBER
19010024 REV A, 01-26-17
PART #’S:
18005056
(For other units, verify compatibility of parts with Technical Support before ordering)
SERVICE PARTS
ITEM # PART NUMBER DESCRIPTION QTY
1 19004310 Condensing Unit, 0.5 HP, MT, R-404A 1
2 19005289 Compressor Kit, NF7CLX, 115V/60Hz 1
3 19005291 Relay, Start, for NF7CLX, 115V/60Hz 1
4 19005292 Capacitor, Start, for NF7CLX, 115V/60Hz 1
5 70008094 Overload 1
6 19008907 Refrigeration Receiver 1
7 3126151 Switch, Carling LTA201TRB/125N 1
8 19004313 Switch, High Limit 1
9 19008906 Filter Drier, 1/4” 1
10 19008902 Fan Motor, Condenser, 9W 1
11 19000454 Fan Motor, Evaporator 2
12 19001190 Valve, Thermostatic Expansion, #1 1
13 19004308 Heating Element, Defrost 1
14 19004309 Gasket, Door 1
15 19004449 Gasket, Lid 1
16 19000817 Caster, Swivel, with Brake, Plate 4
17 19000282 Cord Set, 1/43 SJTOW, 105C Stranded 1
18 19004376 Wiring Harness 1
19 18005958 Controller, Eliwell 1
20 19004832 Temperature Sensor, Coil, Eliwell 1
21 19004769 Temperature Sensor, Air, Eliwell 1
NOTICE!
SERVICE PERFORMED BY NON-AUTHORIZED SERVICE PROVIDERS OR USE OF NON-OEM PARTS MAY VOID EQUIPMENT WARRANTY.
Franke Foodservice Solutions, Inc.
800 Aviation Parkway
Smyrna, TN 37167, USA
Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
Outside the US:
1.615.462.3231, opt. 2
www.frankefs.com
ELIWELL CONTROL SETTINGS & OPERATING CHARACTERISTICS
(For Trouble Shooting Reference) Bottled Beverage Refrigerator
Temperature Controller Options For More Information
Temperature Range Adjustable
Coldest Set Point -30°F
Normal Cut Out (Set Point) -4°F
Normal Cut In -2°F
Warmest Set Point 30°F
Compressor Protection Fixed
Minimum Time From Start to Start 2 minutes
Fail Safe Mode (if sensor fails) Fixed
Faulty Probe On Time 4 minutes
Faulty Probe Off Time 2 minutes
Defrost Settings Fixed
Termination Temp 60°F
Maximum Time Allowed 60 minutes
Drip Time (heat off) 1 minute
Defrost Based On Compressor On Time Fixed
Time Between Defrosts 3 hours
Fan Settings Fixed
During Defrost Off
Start Delay After Defrost 4 minutes
Start Delay N/A
Display Features Adjustments See Service Manual for Instructions
Can select degrees F or C? No
Can adjust temperature from display? Yes
Can Initiate Defrost from display? Yes
Display During Defrost Cycle:
dEF
Refrigerant Type Amount, Ounces
R-404A HCMF-30 19 oz
Normal Operating Pressures Normal Operating Amps
High Side (85 air to condenser) 235 PSIG HCMF-30 8 - 9 Amps, 4.8 Amp Defrost
Low Side (-5 air into coil) 13 PSIG HCMF-18 5 - 6 Amps, 3.8 Amp Defrost
High Pressure Safety Rated Operating Amps
Cut Out Setting 460 PSIG HCMF-30 10 Amps
Differential 30 PSIG HCMF-18 7 Amps
Defrost High Limit Safety Operating Voltage
Cut Out Setting 70°F HCMF-30 120V
Differential 15°F HCMF-18 120V
See Service Manual for Adjusting Temperature
Display Error Codes: E1 = Air Sensor Error, E2 = Defrost
Sensor Error, AH1 = High Alarm, AL1 = Low Alarm, Ad2 =
Defrost Timeout Alarm
Fan cycles on and off after compressor shuts off. Fans on
when compressor is on.
dEF Message shown for a maximum 30 minute after defrost
HCMF-18 11 oz
© 2016 Franke Foodservice Solutions, Inc. This media is the confidential and proprietary
property of Franke Foodservice Solutions, Inc. and shall not be reproduced in any form
of media without the express written permission of Franke. Due to continuous product
development, Franke reserves the right to make changes in design and specifications
without prior notice. Trademarks used are the property of their respective owners.
Printed in the USA under license by Franke Technology and Trademark Ltd., Switzerland.
For Support, Please Call:
Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
Outside the US:
1.615.462.3231, opt. 2