Franke Foodservice HCMF-18 18005560 Service Manual

HCMF Service Manual
High Capacity Meat Freezers
Model HCMF-18 (18” wide) Model HCMF-30 (30” wide)
Section Contents Section Page
HCMF Model Overview & Specifications 1 2 Control Settings & Operating Parameters 2 4 Electric & Compressor Schematics 3 5 Trouble Shooting Table 4 7 Eliwell Controller Error Codes 5 9 Component Parts List & Diagrams 6 11 Basic Operator Preventive Maintenance 7 13 General Unit Service Instructions & Warnings 8 14 Key Parts Replacement Tips 9 15 Component Adjustments 10 19
For Technical Support, Call 800-537-2653. Page 1 Doc. No. 19005309 - Copyright 2012 Franke, Inc.
HCMF Service Manual
Key Performance Specifications
Product Model:
HCMF
-18HCMF
-30Part Number:
1800
5560
1800
5519*
Capacity: Cubic Feet
Capacity:
Burgers
Refrigeration/Type:
Agency Listings:
&
NSF
&
NSF
Key Dimensions & Weights
Unit Width
:
Unit Depth
[front
-to-
back]:
Unit Height
Minimum Door Swing
Shipping Weight
Unit Operating Weight
Electric
al
/Utility Requirements
Voltage [VAC]
Phase [PH]
Cycles [Hz]
Amperage [AMP]
Watts
Power Cord Provided
Plug Provided
Installation/Operating Conditions/Requirements
Max. Room Temp.
Max. Room Humidi
ty
Min. Side Clearance
Min. Rear Clearance
Section 1 – Model Overview & Specifications:
Model HCMF Series – High Capacity Meat Freezers
The HCMF is a compact, custom freezer designed for short-term grill-side storage of frozen hamburger patties and secondary grilled product, providing quick and easy access at point-of-use. Designed to be positioned immediately adjacent to the Grill Station, the HCMF is available in two sizes, 18-inches wide and 30-inches wide, with a front case-loading door and an insulated, automatic roll-back top lid that provides quick access, with minimum exposure of frozen product.
Unlike previous grill-side freezers (GSF & FRGSF), HCMF Models have a top mounted condenser package that provides easy access for regular PM and service access from five sides. HCMF Models are more energy efficient, provide more storage space, cost less to operate and have the following specifications and utility requirements:
6.8 13.1
3 box 6 boxes
Forced air cooling system using R-404A Refrigerant
CULUS
CULUS
18” (458 mm) 30.86” (784 mm) 37” (940 mm) 37” (940 mm)
54.77” (1391 mm) 54.77” (1391 mm) +22” (to depth) +32” (to depth)
337 lbs. 427 lbs. 265 lbs. 365 lbs.
120 VAC 120 VAC
1-phase 1-phase
60 Hz 60 Hz
7.3 AMPs 10 AMPs 840 1200 Yes Yes
Straight Blade Straight Blade
82F 82F
60% 60% 0” (2” recommended) 0” (2” recommended) 1” (2” recommended) 1” (2” recommended)
* NOTE: P/N: 18005519 has the condenser mounted top-right. P/N 18005056 has the
condenser factory-mounted top-left.
For Technical Support, Call 800-537-2653. Page 2 Doc. No. 19005309 - Copyright 2012 Franke, Inc.
HCMF Service Manual
Casters
Model HCMF Key Components
HCMF-30 [18005519 – Condenser-Right] Model Shown
Front Vented Condenser Coil Access Panel
Top Roll-Back Product Access Door
Temperature Display/Controller
Grill Tool Shelf
Right Side Service Access Panel
Disposable Glove Bracket Mounting Location
Front Door (Shown Hinged Right – Field Reversible)
Power ON/OFF Switch
Locking Front
(Rear-View)
For Technical Support, Call 800-537-2653. Page 3 Doc. No. 19005309 - Copyright 2012 Franke, Inc.
HCMF Service Manual
NOTE:
dEF shown for maximum of 30
Refrigeration Type
& Quantity
:
HCMF
-30HCMF
-
18
Section 2 – Control Settings & Operating Parameters:
Control Settings & Operating Characteristics (For Troubleshooting)
Danfoss Temperature Controller For More Information
Temperature Range Adjustable
Coldest Set Point -30 degrees F Normal Cut Out (Set Point) - 4 degrees F Differential 2 degrees F Normal Cut In - 2 degrees F Warmest Set Point +30 degrees F
Compressor Protection Fixed
Minimum On Time from Start to Start 2 minutes
Fail Safe Mode (if sensor fails) Fixed
Faulty Probe On Time 4 minutes Error Off Time 2 minutes
Defrost Settings Fixed
Termination Temperature 60 degrees F Maximum Time Allowed 60 minutes Drip Time (heat off) 1 minute
Defrost Based On Compressor On Time Fixed
Time Between Defrosts 3 hours
Fan Settings Fixed
During Defrost Off Start Delay After Defrost 4 minutes Fan Duty Cycle – ON 40 seconds Fan Duty Cycle - OFF 90 seconds
Display Features: Adjustments
Select degrees F or C? No Adjust temperature from display? Yes
Initiate Defrost from display? Yes
See Section 10 on page 19 to adjust temperature
NOTE: Contact Franke for degrees C See Section 10 on page 19 to adjust
temperature or initiate manual defrost
Display during Defrost Cycle:
dEF
minutes after defrost.
Normal Operating Pressures Normal Operating Amps
High Side (85 air to condenser) 235 PSIG HCMF-30 8 – 9 Amps (4.8A Defrost) Low Side (-5 air into coil) 13 PSIG HCMF-18 5 – 6 Amps (3.8 Defrost)
High Pressure Safety Rated Operating Amps
Cut Out Setting 460 PSIG HCMF-30 10 Amps Differential 30 PSIG HCMF-18 7.3 Amps
Defrost High Limit Safety Operating Voltage
Cut Out Setting 70 degrees F HCMF-30 120V Differential 15 degrees F HCMF-18 120V
R-404A 18 ounces 16 ounces
For Technical Support, Call 800-537-2653. Page 4 Doc. No. 19005309 - Copyright 2012 Franke, Inc.
HCMF Service Manual
NOTE:
Section 3 – Electric & Compressor Schematics:
HCMF-18 & HCMF-30 Wiring Harness
Model HCMF-18 has one fan motor Model HCMF-30 has two fan motors
For Technical Support, Call 800-537-2653. Page 5 Doc. No. 19005309 - Copyright 2012 Franke, Inc.
HCMF Service Manual
Model HCMF-18 – Copeland No. M4FL-H038-IAA-121 – Franke P/N: 19004507 Model HCMF-30 – Copeland No. M4FL-H047-IAA-121 – Franke P/N: 19004310
Copeland Compressor Schematic
For Technical Support, Call 800-537-2653. Page 6 Doc. No. 19005309 - Copyright 2012 Franke, Inc.