Frank Door EFD-ESS-1 User Manual

Model EFD-ESS-1
The FRANK Energy Saver Door is used for personnel and hand truck traffic in buildings where environmental control is essential. Suitable for coolers, freezers and environmental test chambers. The design incorporates a 2” thick foamed-in-place exterior overlap with a low profile interior. The hardware package further enhances the insulating qualities by mechanically compressing the gasket. This design has unlimited applications.
Standard Features
Panel
No Wood Construction 24 Gauge Metal Skins .040 Embossed Aluminum Skins Robust Extruded Aluminum Sub-frame
Insulation
At Least 4” Thick, R32 Foamed In Place Polyurethane Panel Mounted Gasket
Hardware
Bullet Hinge Rotary Compression Latch Cylinder Lock Integrated Inside Release Available with No Exterior Hardware
Side Casings and Header
Insulated Extruded Aluminum Sweep Bottom or High Sill
Freezer Doors
Three Sided Heat in the Frame Heat Radiating Bottom Door Pan Door Panel Heat Protected Heat Chase U.L. Listed Heaters
Energy Saver Single Swing
Manual Cold Storage Door
PRODUCT DATA
Options
Panel
Other Metal Finishes and Colors Available Molded Fiberglass Door Panels Available Diamond Tread or Stainless Steel Kick Plates Three Pane Heated View Window 6” Thick Panels Available
Hardware
Assist Wheel Door Closer Spring Loaded Hinges Multi Point Latching
Side Casings and Header
Jamb Caps Return Jambs Trackport Rain Hood Extruded Aluminum Back Up Header and Casings Other Metal Finishes and Colors Available
As the Frank Door Company constantly strives to build the highest quality products for performance and value,
the design, specifications, materials, features and prices are subject to change without notice.
The New American Standard in Cold Storage Doors
Frank Door Company 413 Howard Blvd., Newport, North Carolina USA 28570
www.frankdoor.com Toll Free (888)833-3667 Phone (252)223-1112 Fax (252)223-1116
Energy Saver Single Swing
Manual Cold Storage Door
Downloadable drawings and CSI formatted specifications are available at www.frankdoor.com
Single Swing Manual ESS-1 Type Cold Storage Door
Division 13 Section 13010
Cold Storage Doors Section 08 38 00
Part 1 - General
1.0.1 Scope
Work required under this section shall include the furnishing of all labor, materials, tools and equipment necessary to complete all work as detailed on the drawings and/or as specified herein.
1.0.2 Product
Supply, where indicated on the plans, a Frank Door Model ESS-1 (single swing manual ESS-1 type cold storage door). Door panel shall be constructed of an extruded, aircraft grade aluminum profile with steel corner reinforcements and clad with a choice of metal skins. Door panel shall
contain at least 4” of foamed-in-place polyurethane insulation (R32) with an insulated overlap of the opening’s perimeter. Insulated wall casings and header shall be aircraft grade aluminum
extrusions. Gasketing shall be panel mounted compression gasket and bottom sweep. Bullet style gravity hinges and lockable rotary compression latch shall be made of corrosion resistant materials. No organics such as wood or wood composites shall be used in the door panel, casings or header. Doors shall be built to NSF standards.
1.0.3 Substitutions
This specification is written with Frank Door Company Model EFD-ESS-1 as the basis of acceptable materials, construction and performance. No substitutions will be considered unless
written request for approval is received in the architect’s office at least 14 days prior to the
release of the bids.
DRAWINGS & SPECIFICATIONS
1.0.4 Submittals
In compliance with the specification requirements, submit detailed shop drawings for each door, showing in clear detail of all mounting requirements and accessories.
1.0.5 Quality Assurance
Doors shall be installed in accordance with the architect's plans and specifications and the door manufacturer's written installation instructions, drawings and recommendations. Doors shall carry a 5 year limited warranty for the door panel, door frame, trim, vertical casings and header and a 2 year limited warranty on all other Frank Door Company manufactured components with the exception of typical wear components. Frank Door Company also warrants all products or component parts not manufactured by Frank Door Company to the same extent that they were warranted by the original manufacturer to the Frank Door Company.
Part 2 - Product
2.0.1 Material
Casings/Header
Extruded aluminum profiles with insulated polystyrene inserts. (Matching back up headers and casings are optional. Return jambs are optional. Jamb caps are optional.) No organics such as wood or wood composites shall be accepted. All sweep bottom freezer doors shall be equipped with a heater cable in the three sided casing frames. All high sill freezer doors shall be equipped with a full perime­ter heater cable in the casing frames.
Door Panel
The door panel shall be constructed of an aircraft grade aluminum extrusion with mitered corners, steel corner brackets and clad with two USDA approved 24 gauge steel or.040 aluminum face sheets (Smooth white and stainless steel face sheets are optional.) to enclose the frame. Backup blocking is used at all hinge, latch, handle, closer and lock attachment points. The panel is foamed-in-place with
at least 4” of polyurethane insulation (R32) with a 2” thick by 1.5” wide overlap around the full
perimeter of the opening. Gasketing shall be panel mounted compression gasket and a bottom sweep. (Optional triple pane view window shall be sealed, heated and constructed with heat reflective tem­pered safety glass and metal frame. Aluminum diamond plate and stainless steel kickplates are optional). No organics such as wood or wood composites shall be used for the door panel structure or blocking. All freezer doors shall be equipped with full perimeter door panel heat.
Hinges and Door Hardware
Hinges shall be bullet-style, cam-lift, adjustable and tamper resistant. Latch shall be a lockable rotary compression latch with safety release hardware on opposite side. (Door closer is optional). All hard­ware and mechanisms shall be corrosion resistant materials.
Part 3 - Execution
3.0.1 Installation
Doors shall be mounted in full accord with the door manufacturer’s installation instructions and
contract documents. When mounting the door casings and header, the mounting surfaces shall be set true and level, be shimmed and caulked to assure tightness and fit, securely lagged or through bolted to the wall structure. After the doors are hung, they shall be checked for mechanical operation and adjusted to insure a tight and uniform perimeter gasket seal. Connection of any panel or window heating is the responsibility of the electrical contractor.
3.0.2 Product Delivery, Storage and Handling
Each cold storage door shall be securely crated as to protect the door from damage during shipment and handling. Door identification number shall be clearly marked on the outside of each crate.
3.0.3 Cleaning and Adjustment
Clean all doors of excess sealant, grease, stains, fingerprints and construction dust prior to final inspection to the satisfaction of the architect/owner. Adjust all doors for smooth, proper operating condition, including proper sealing and lubrication, prior to turnover of facility to owner.