Altitude 1: Absolute altitude
Altitude 2: Relative altitude
Power voltage is indicated, on the analog vario display (2 ) for approximately 10 seconds and «Po» for power on the digital vario
display. When all the segments in the ascent sector (green) light up, this indicates that the batteries have an energy reserve of 100%.
descent sector (red) and «Po». lf this occurs, the unit does not shift into operating mode.
1. Changeover into adjustment mode is effected by pressing a key (8, 9 or 11) for several (approx. 4) seconds. The corresponding
display will then ash intermittently and can be reset.
2. Use the reset key -Up- (6) or Down- (7) to set the required value. When entering altitude gures, the number display can be speeded up by
3. Finish by pressing the corresponding original key. When setting the altitude there is automatic acknowledgement after approx. 10 sec.
Altitude 1: Absolute altitude. Can be set within weather-de pendent tolerances.
Altitude 2: Relative altitude. Can be set whenever required over the whole measurement range and zeroed at any time by pressing the key «CLEAR
ALTI 2» (7). It Can also be cleared while ALTI 1 is shown on the display. Operating the changeover key ALTI 1 - ALTI 2 (11) indicates the desired altitude
and marks it with an arrow.
displayed (sec Setting mode).
Altimeter 2 (ALTI 2) can be used to indicate a gain or loss in altitude, as it can be zeroed at any time using the key «CLEAR ALTI
2» (7) even while ALTI 1 is displayed.
Fully automatic segment display over the entire range. Individual segments remain displayed, until the end of the rst scale sector is
Display over the entire range.
Changeover into the vario attenuation setting mode is effected by pressing the volume key (9) for several (approx. 3)
seconds (c.f. Setting mode). Four selectable, average value computations are possible for the digital vario display:
d0 = average value for the last second (4 measurements per second)
d1 = average value for the last 3 seconds
d2 = average value for the last 10 scconds
d3 = average value for the last 30 seconds
The analog vario display is not attenuated.
Sound can either be switched off entirely or 2 volume levels can be set by repeatedly pressing the volume key (9). The volume level
currentIy set will sound when the key is pressed.
When the unit is switched on, the volume is automatically set at level 1.
A sound interval with a rising tone frequency dependent on ascent frequency and a timbre dependent on scale (ASI: Acoustic Scale

A continuous falling tone frequency de pendent on descent with a timbre dependent on scale (ASI: Acoustic Scale
descent sector of the vario display to indicate the current response point. When the descent tone/alarm is switched off, pressing the key will not produce
The descent tone/alarm will only, sound when the vario acoustic facility is switched on.
When the descent tone key ( 8 ) is pressed for approx. 3 seconds, the unit moves into the adjustment mode for descent tone/alarm (see Setting mo de).
The response point can be adjusted within the rst sector of the scale.
The vane-wheel sensor is connected to the socket (12) on the right-hand side of the unit. The indicator replaces the digital vario display
the digital vario display and the speed indicator.
Pressing the MEMO key (10) will display the peak values (max. absolute altitude 2 and maximum ascent) of the current ight (F0).
a clear difference in altitude).
Unscrew the battery compartment. Use two 1.5 V batte ries. Please do well observe the polarity (+/-). After the battery change, switch on
the instrument and control the display. Now switch off the instrument again. lf the instrument stays for more than one minute without batteries the MEMO
Open the unit immediately. lf salt water has entered the unit, rinse it thoroughly (the printed circuit board, in particular) with hand-hot fresh
water. Allow the unit to dry as well as possible, preferable in the sun. lf this is not possible, the unit must be placed on a piece of wood in an oven. Allow
the unit to dry off for one or two hours as required, at a temperature of approx. 50ºC. Leave the oven door open slightly to allow any moisture to escape!
N.B. Never put the unit in a microwave oven!
Clip or special attachment for hangglider ( t to the rear of the unit). The clip can be unscrewed, twisted 90º and re tted.
Adjusting the security cord:
Open the unit, cut the cord to the required length and knot it well. Tighten the cord from the outside and screw the unit
Return the unit to your nearest FLYTEC service agent.