Fluke PN 4060712 User Manual

62 MAX/62 MAX +
Infrared Thermometer
PN 4060712 April 2012 © 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warrant y period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.
11/99
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands

Table of Contents

Title Page
Introduction ................................................................................................................. 1
How to Contact Fluke ................................................................................................. 1
Safety Information ...................................................................................................... 2
Maintenance ............................................................................................................... 5
How to Change the Battery .................................................................................... 5
How to Clean the Product ...................................................................................... 5
Specifications ............................................................................................................. 6
Standards and Agency Approval ................................................................................ 8
The Product ................................................................................................................ 9
i
62 MAX/62 MAX +
Users Manual
ii

Introduction

The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target’s surface. Note that the Japanese models indicate Celsius only.
WWarning
Read all safety information before you use the Product.

How to Contact Fluke

To contact Fluke, call one of the following telephone numbers:
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-03-6714-3114
Singapore: +65-6799-5655
Anywhere in the world: +1-425-446-5500
1
62 MAX/62 MAX +
Users Manual
Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To see, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals.

Safety Information

A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test.
Table 1 tells you about symbols used on the Product and in this manual.
*WWarning
To prevent eye damage and personal injury:
Read all safety Information before you use the Product.
Do not use the Product if it operates incorrectly.
Use the Product only as specified, or the protection supplied by the
Product can be compromised.
Before you use the Product, inspect the case. Do not use the Product if it
appears damaged. Look for cracks or missing plastic.
2
Infrared Thermometer
Safety Information
See emissivity information for actual temperatures. Reflective objects
result in lower than actual temperature measurements. These objects pose a burn hazard.
Do not look directly into the laser with optical tools (for example,
binoculars, telescopes, microscopes). Optical tools can focus the laser and be dangerous to the eye.
Do not look into the laser. Do not point laser directly at persons or
animals or indirectly off reflective surfaces.
Replace the batteries when the low battery indicator shows to prevent
incorrect measurements.
Do not use the Product around explosive gas, vapor, or in damp or wet
environments.
Use the Product only as specified or hazardous laser radiation exposure
can occur.
3
62 MAX/62 MAX +
Users Manual
Table 1. Symbols
Symbol Meaning Symbol Meaning
Do not dispose of this product as
W
*
4
Risk of danger. Important information. See Manual.
Warning. Laser. P Battery
unsorted municipal waste. Go to
~
Fluke’s website for recycling information.
Conforms to European Union directives.
Conforms to relevant Australian standards.
Infrared Thermometer

Maintenance

Maintenance
WCaution
To avoid damage to the Product, do not leave the thermometer on or near objects of high temperature.

How to Change the Battery

To install or change the AA IEC LR06 battery, open the battery compartment and replace the battery as shown in Figure 16.

How to Clean the Product

Use soap and water on a damp sponge or soft cloth to clean the Product case. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. See Figure 17.
5
62 MAX/62 MAX +
Users Manual

Specifications

Temperature Range
Accuracy
Response Time (95 %) <500 ms (95 % of reading) <300 ms (95 % of reading) Spectral Response 8 to 14 microns Emissivity 0.10 to 1.00
6
-30 °C to 500 °C (-22 °F to 932 °F)
0 °C: ±1.5 °C or ±1.5 % of reading, whichever is greater
(32 °F: ±3 °F or ±1.5 % of reading, whichever is greater)
-10 °C to <0 °C: ±2 °C (14 °F to <32 °F: ±4 °F) < -10 °C: ±3 °C (<14 °F: ±6 °F)
62 MAX 62 MAX +
-30 °C to 650 °C (-22 °F to 1202 °F)
0 °C: ±1 °C or ±1 % of reading, whichever is greater (≥32 °F: ±2 °F or ±1 % of reading, whichever is greater)
-10 °C to <0 °C: ±2 °C (14 °F to <32 °F: ± < -10 °C: ±3 °C (<14 °F: ±6 °F)
4 °F)
Infrared Thermometer
Specifications
Optical Resolution Display Resolution Repeatability (% of reading) Power 1 AA IEC LR06 Battery Battery Life Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches Operating Temperature Storage Temperature Operating Humidity Operating Altitude 2000 meters above mean sea level Storage Altitude 12,000 meters above mean sea level
10:1 (calculated at 90 % energy)
0.1 °C (0.2 °F) ±0.8 % of reading or ±1.0 °C
(2 °F), whichever is greater
10 hours with laser and backlight on
0 °C to 50 °C (32 °F to 122 °F)
-20 °C to 60 °C (-4 °F to 140 °F), (without battery) 10 % to 90 % RH non-condensing @ 30 °C (86 °F)
12:1 (calculated at 90 % energy)
±0.5 % of reading or ±0.5 °C (1 °F), whichever is greater
8 hours with laser and backlight on
7
62 MAX/62 MAX +
Users Manual
IP Rating IP 54 per IEC 60529 Drop Test 3 meters Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance ............................................. EN/IEC 61010-1: 2001
Laser Safety ............................................ FDA and EN 60825-1 Class II
8
Infrared Thermometer
The Product

The Product

1 2
gtt01.eps
9
62 MAX/62 MAX +
Users Manual
3 4
/
5
56
Max/Min/Avg/Diff
10
gtt14.eps
Infrared Thermometer
The Product
7
+
10 min
=
OFF
gtt16.eps
11
62 MAX/62 MAX +
Users Manual
12
0ºC
32ºF
8
10
30 Min
12
6
9
11
39
22ºC 72ºF
125°F
gtt15.eps
Infrared Thermometer
The Product
12 13
38 mm @
300 mm
60 mm @
600 mm
100 mm @
900 mm
33 mm @
300 mm
50 mm @
600 mm
85 mm @
900 mm
1.5" @
2.4" @
12"
24"
62 MAX D:S = 10:1
S
4" @
36"
D
1.4" @ 12"
2" @
24"
D
S
3.4" @ 36"
62 MAX + D:S = 12:1
gtt08-11.eps
13
62 MAX/62 MAX +
Users Manual
14
14
70
21
gtt03.eps
Infrared Thermometer
The Product
15
75°
225°
75°
gtt04.eps
15
62 MAX/62 MAX +
Users Manual
16 17
-
+
16
gtt13.eps
Loading...