Fluke 8845A User Manual

Page 1
Fluke 8845A/8846A
Digital Multimeters
Extended Specifications
The Fluke 8845A and 8846A 6.5 digit precision multime­ters have the precision and versatility to handle your most demanding measurements, on the bench or in a system. These meters are both high performance and feature rich, yet also remarkably easy to use.
Features at a glance
6.5 digit resolution
Basic V dc accuracy of up to 0.0024 % (1 yr.)
Dual display
100 μA to 10 A current range, with up to 100 pA resolution
Wide ohms ranges from 10 W to 1 GW with up to 10 μW resolution
2 x 4 ohms 4-wire measurement technique
Both models measure frequency and period
8846A also measures capacitance and temperature
USB memory drive port (8846A)
Fluke 45 and Agilent 34401A emulation
Graphical display
Trendplot paperless recorder mode, statistics, histogram
CAT I 1000 V, CAT II 600 V
You can also use the 8845A and 8846A to measure tempera­ture, capacitance, period, and frequency—the functions of a counter, capacitance meter, and thermometer are built in for unparalleled versatility. Extend the meters’ utility even more with their graphical display modes, including Trendplot paperless recorder mode, statis­tics and histograms—features you won’t find on other multimeters.
Of course, these meters are also durable and dependable, features you expect from any Fluke meter. This unique combi­nation of features and perfor­mance makes the 8845A and 8846A an unbeatable value for a wide variety of applications, including manufacturing test, research and development, and service.
Page 2
General Specifications
Power
Voltage
100 V Setting............................................................. 90 V to 110 V
120 V Setting............................................................. 108 V to 132 V
220 V Setting............................................................. 198 V to 242 V
240 V Setting............................................................. 216 V to 264 V
Frequency........................................................................ 47 Hz to 440 Hz. Automatically sensed at power-on.
Power Consumption....................................................... 28 VA peak (12 Watt average)
Dimensions
Height .............................................................................. 88 mm (3.46 in.)
Width ............................................................................... 217 mm (8.56 in.)
Depth................................................................................ 297 mm (11.7 in.)
Weight ............................................................................. 3.6 kg (8.0 Ibs.)
Shipping Weight ............................................................5.0 kg (11.0 lbs)
Display
Vacuum Fluorescent Display, dot matrix
Environment
Temperature
Operating.................................................................... 0 °C to 55 °C
Storage........................................................................ -40 °C to 70 °C
Warm Up..................................................................... 1 hour to full uncertainty specifications
Relative Humidity (non-condensing)
Operating.................................................................... 0 °C to 28 °C <90 %
28 °C to 40 °C <80 % 40 °C to 55 °C <50 %
Storage........................................................................ -40 °C to 70 °C <95 %
Altitude
Operating.................................................................... 2,000 Meters
Storage........................................................................ 12,000 Meters
Vibration and Shock......................................................Complies with Mil-T-28800F Type III, Class 5 (Sine Only)
Safety
Designed to comply with IEC 61010-1:2000-1, UL 61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V/CAT II 600V
EMC
Designed to comply with IEC 61326-1:2000-11 (EMC) when used with shielded communications cables. This Meter has shown susceptibility to radiated frequencies greater than 1 V/m from 250 to 450 MHz in the 100 μA range.
Triggering
Samples per Trigger..................................................1 to 50,000
Trigger Delay..............................................................0 S to 3600 S; in 10 µS increments
External Trigger Delay..............................................<1 mS
External Trigger Jitter...............................................<500 µS
Trigger Input..............................................................TTL Levels
Trigger Output............................................................5 V maximum. (Open collector)
Memory
8845A.........................................................................5,000 measurements, Internal only
8846A.........................................................................5,000 measurements, Internal and up to 2 Gigabyte capacity with USB memory module
(available separately. see “Accessories”) through front-panel USB port
Math Functions
Zero, dBm, dB, MX+B, Trend-plot, Histogram, Statistics (min/max/average/standard deviation), and Limit Test
8845A and 8846A Fluke Corporation 1
Page 3
Electrical
Input Protection............................................................1000 V all ranges
Overrange.......................................................................20 % on all ranges except 1000 V dc, 1000 V ac (8846A),
750 V ac (8845A), Diode, and 10 A ranges
Remote Interfaces
RS-232 (RS-232 to USB cable available to connect the Meter to a PC USB port. See accessories) IEEE 488.2 LAN
Warranty
One year
Electrical Specifications
Accuracy specifications are valid for 6½ digit mode after at least a 1-hour warm-up with Auto Zero enabled. 24-hour specifications are relative to calibration standards and assume a controlled electromagnetic environment per EN 61326-1:2000-11
DC Voltage Specifications
Maximum Input.............................................................1000 V on any range
Common Mode Rejection............................................140 dB at 50 or 60 Hz ± 0.1 % (1 kΩ unbalance)
Normal Mode Rejection ..............................................60 dB for NPLC of 1 or greater with dc filter off and power line frequency ±0.1 %
100 dB for NPLC of 1 or greater with dc filter on and power line frequency ±0.1 %
Measurement Method..................................................Multi-ramp A/D
A/D Linearity.................................................................0.0002 % of measurement + 0.0001 % of range
Input Bias Current........................................................<30 pA at 25 °C
Autozero Off Operation...............................................Following instrument warm-up at calibration temperature ±1 °C and less than 10
minutes, add error: 0.0002 % range additional error + 5 μV.
Settling Considerations..............................................Measurement settling times are affected by sourc e impedance, cable dielectric
Input Characteristics
Range
100 mV 100.0000 mV 10 µV 1 µV 100 nV 10 MΩ or >10 GΩ 1 V 1.000000 V 100 µV 10 µV 1 µV 10 MΩ or >10 GΩ 10 V 10.00000 V 1 mV 100 µV 10 µV 10 MΩ or >10 GΩ 100 V 100.0000 V 10 mV 1 mV 100 µV 10 MΩ ±1% 1000 V 1,000.000 V 100 mV 10 mV 1 mV 10 MΩ ±1%
[1] Inputs beyond ±14 V are clamped through 200 kΩ typical. 10 MΩ is default input impedance.
Full Scale
(6½ Digits)
4½ Digits 5½ Digits 6½ Digits
8846A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range
100 mV 0.0025 + 0.003 0.0025 + 0.0035 0.0037 + 0.0035 0.0005 + 0.0005 1 V 0.0018 + 0.0006 0.0018 + 0.0007 0.0025 + 0.0007 0.0005 + 0.0001 10 V 0.0013 + 0.0004 0.0018 + 0.0005 0.0024 + 0.0005 0.0005 + 0.0001 100 V 0.0018 + 0.0006 0.0027 + 0.0006 0.0038 + 0.0006 0.0005 + 0.0001 1000 V 0.0018 + 0.0006 0.0031 + 0.001 0.0041 + 0.001 0.0005 + 0.0001
24 Hour
(23 ± 1 °C)
(23 ± 5 °C)
8845A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range
100 mV 0.003 + 0.003 0.004 + 0.0035 0.005 + 0.0035 0.0005 + 0.0005 1 V 0.002 + 0.0006 0.003 + 0.0007 0.004 + 0.0007 0.0005 + 0.0001 10 V 0.0015 + 0.0004 0.002 + 0.0005 0.0035 + 0.0005 0.0005 + 0.0001 100 V 0.002 + 0.0006 0.0035 + 0.0006 0.0045 + 0.0006 0.0005 + 0.0001 1000 V 0.002 + 0.0006 0.0035 + 0.0010 0.0045 + 0.0010 0.0005 + 0.0001
24 Hour
(23 ± 1 °C)
(23 ± 5 °C)
characteristics, and input signal changes.
Resolution
90 Days
90 Days
1 Year
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Input Impedance
[1] [1] [1]
2 Fluke Corporation 8845A and 8846A
Page 4
Additional Errors
Digits NPLC Additional Noise Error
100 0 % of range 6½ 10 0 % of range 5½ 1 0.001 % of range 5½ .2 0.001 % of range + 20 μV 0.02 0.01 % of range + 20 μV
AC Voltage Specifications
AC Voltage specifications are for ac sinewave signals >5 % of range. For inputs from 1 % to 5 % of range and <50 kHz, add an additional error of 0.1 % of range, and for 50 to 100 kHz, add 0.13 % of range.
Maximum Input.............................................................750 V rms or 1000 V peak (8845A), 1000 V rms or 1414 V peak (8846A) or 8 x 10
Volts-Hertz product (whichever is less) for any range.
Measurement Method..................................................AC-coupled true-rms. Measures the ac component of input with up to 1000 V dc bias on
any range.
AC Filter Bandwidth:
Slow.............................................................................3 Hz – 300 kHz
Medium.......................................................................20 Hz – 300 kHz
Fast..............................................................................200 Hz – 300 kHz
Common Mode Rejection............................................70 dB at 50 Hz or 60 Hz ±0.1 % (1 kΩ unbalance)
Maximum Crest Factor................................................5:1 at Full Scale
Additional Crest Factor Errors (<100 Hz) ..............Crest Factor 1-2, 0.05 % of full scale
Crest Factor 2-3, 0.2 % of full scale Crest Factor 3-4, 0.4 % of full scale Crest Factor 4-5, 0.5 % of full scale
Input Characteristics
Range
Full Scale
(6½ Digits)
4½ Digits 5½ Digits 6½ Digits
100 mV 100.0000 mV 10 µV 1 µV 100 nV 1 V 1.000000 V 100 µV 10 µV 1 µV 10 V 10.00000 V 1 mV 100 µV 10 µV 100 V 100.0000 V 10 mV 1 mV 100 µV 1000 V 1,000.000 V 100 mV 10 mV 1 mV
Resolution
Input Impedance
1 MΩ ±2 % shunted by <100 pf
8846A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range Frequency
100 mV
3 – 5 Hz 1.0 + 0.03 1.0 + 0.04 1.0 + 0.04 0.1 + 0.004
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
5 – 10 Hz 0.35 + 0.03 0.35 + 0.04 0.35 + 0.04 0.035 + 0.004 10 Hz – 20 kHz 0.04 + 0.03 0.05 + 0.04 0.06 + 0.04 0.005 + 0.004 20 – 50 kHz 0.1 + 0.05 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
1 V
50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 – 300 kHz 3 – 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.20 + 0.02
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
10 V
50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 – 300 kHz 3 – 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
100 V
50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 – 300 kHz 3 – 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005 50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 –- 300 kHz
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
7
8845A and 8846A Fluke Corporation 3
Page 5
Range Frequency
1000 V
3 – 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005 50 – 100 kHz 100 – 300 kHz
[1] Typically 30 % reading error at 1 MHz [2] 1000 Volt range is limited to 8 X 10
[2]
0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008
[1][2]
4.0 + 0.5 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
7
volt-Hertz
8845A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range
100 mV
Frequency
(Hz)
3 – 5 Hz 1.0 + 0.03 1.0 + 0.04 1.0 + 0.04 0.10 + 0.004
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
5 – 10 Hz 0.35 + 0.03 0.35 + 0.04 0.35 + 0.04 0.035 + 0.004 10 Hz – 20 kHz 0.04 + 0.03 0.05 + 0.04 0.06 + 0.04 0.005 + 0.004 20 – 50 kHz 0.1 + 0.05 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
1 V
50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 – 300 kHz 3 – 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
10 V
50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 – 300 kHz 3 – 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
100 V
50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 – 300 kHz 3 – 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
750 V
50 – 100 kHz 0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008 100 – 300 kHz 3 –- 5 Hz 1.0 + 0.02 1.0 + 0.03 1.0 + 0.03 0.1 + 0.003
[1]
4.0 + 0.50 4.0 + 0.50 4.0 + 0.50 0.2 + 0.02
5 – 10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003 10 Hz – 20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003 20 – 50 kHz 0.1 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005 50 – 100 kHz 100 – 300 kHz
[1] Typically 30 % reading error at 1 MHz [2] 750 Volt range is limited to 8 X 10
[2]
0.55 + 0.08 0.6 + 0.08 0.6 + 0.08 0.06 + 0.008
[1] [2]
4.0 + 0.5 4.0 + 0.5 4.0 + 0.5 0.2 + 0.02
7
volt-Hertz
Additional Low Frequency Errors
Error is stated as % of reading.
Frequency
3HZ (slow) 20HZ (medium) 200HZ (fast)
AC Filter
10 – 20 Hz 0 0.25 – 20 – 40 Hz 0 0.02 – 40 – 100 Hz 0 0.01 0.55 100 – 200 Hz 0 0 0.2 200 Hz – 1 kHz 0 0 0.02 > 1 kHz 0 0 0
1 Year
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Temperature
Coefficient/ °C
Outside 18 to 28 °C
4 Fluke Corporation 8845A and 8846A
Page 6
Resistance
Specifications are for 4-wire resistance function, 2 x 4-wire resistance, or 2-wire resistance with zero. If zero is not used, add 0.2 Ω for 2­wire resistance plus lead resistance, and add 20 mΩ for 2 x 4-wire resistance function.
Measurement Method..................................................Current source referenced to LO input.
Max. Lead Resistance (4-wire ohms)......................10 % of range per lead for 100 Ω, 1 kΩ ranges. 1 kΩ per lead on all other ranges.
Input Protection............................................................1000 V on all ranges.
Input Characteristics
Range
[1]
10 Ω 100 Ω 100.0000 Ω 10 mΩ 1 mΩ 100 μΩ 1 mA 1 kΩ 1.000000 kΩ 100 mΩ 10 mΩ 1 mΩ 1 mA 10 kΩ 10.00000 kΩ 1 Ω 100 mΩ 10 mΩ 100 μA 100 kΩ 100.0000 kΩ 10 Ω 1 Ω 100 mΩ 10 μA 1 MΩ 1.000000 MΩ 100 Ω 10 Ω 1 Ω 10 μA 10 MΩ 10.00000 MΩ 1 kΩ 100 Ω 10 Ω 1 μA 100 MΩ 100.0000 MΩ 10 kΩ 1 kΩ 100 Ω 1 μA || 10 MΩ
1.0 GΩ
[1] 8846A Only
Full Scale
(6½ Digits)
10.00000 Ω 1 mΩ 100 μΩ 10 μΩ 5 mA
[1]
1.000000 GΩ 100 kΩ 10 kΩ 1 kΩ 1 μA || 10 MΩ
4½ Digits 5½ Digits 6½ Digits
8846A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range
10 Ω 0.003 + 0.01 0.008 + 0.03 0.01+ 0.03 0.0006 + 0.0005 100 Ω 0.003 + 0.003 0.008 + 0.004 0.01 + 0.004 0.0006 + 0.0005 1 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.0001 10 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.0001 100 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.0001 1 MΩ 0.002 + 0.001 0.008 + 0.001 0.01 + 0.001 0.001 + 0.0002 10 MΩ 0.015 + 0.001 0.02 + 0.001 0.04 + 0.001 0.003 + 0.0004 100 MΩ 0.3 + 0.01 0.8 + 0.01 0.8 + 0.01 0.15 + 0.0002 1 GΩ 1.0 + 0.01 1.5 + 0.01 2.0 + 0.01 0.6 + 0.0002
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
8845A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range
100 Ω 0.003 + 0.003 0.008 + 0.004 0.01 + 0.004 0.0006 + 0.0005 1 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.0001 10 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.0001 100 kΩ 0.002 + 0.0005 0.008 + 0.001 0.01 + 0.001 0.0006 + 0.0001 1 MΩ 0.002 + 0.001 0.008 + 0.001 0.01 + 0.001 0.0010 + 0.0002 10 MΩ 0.015 + 0.001 0.02 + 0.001 0.04 + 0.001 0.0030 + 0.0004 100 MΩ 0.3 + 0.01 0.8 + 0.01 0.8 + 0.01 0.1500 + 0.0002
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
Additional Ohms Errors
Digits NPLC Additional Noise Error
100 0 % of range 6½ 10 0 % of range 5½ 1 0.001 % of range 5½ 0.2 0.001 % of range ± 20 mΩ 0.02 0.01 % of range ± 20 mΩ
Resolution
1 Year
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Source Current
8845A and 8846A Fluke Corporation 5
Page 7
DC Current
Input Protection............................................................Tool-accessible 11 A/1000 V and 440 mA/1000 V fuses.
Input Characteristics
Range
Full Scale
(6½ Digits)
4½ Digits 5½ Digits 6½ Digits
100 µA 100.0000 µA 10 nA 1 nA 100 pA 100Ω <0.015 1 mA 1.000000 mA 100 nA 10 nA 1 nA 100Ω <0.15 10 mA 10.00000 mA 1 μA 100 nA 10 nA 1 Ω <0.025 V 100 mA 100.0000 mA 10 µA 1 μA 100 nA 1 Ω <0.25 V 1 A 1.000000 A 100 µA 10 µA 1 μA 0.01 Ω <0.05 V
[1]
3 A
3.00000A 1 mA 100 µA 10 µA 0.01 Ω <0.15 V
10 A 10.00000 A 1 mA 100 µA 10 µA 0.01 Ω <0.5 V
[1] Part of 10 A range.
Accuracy (8846A)
Accuracy is given as ± (% measurement + % of range)
Range
100 µA 0.01 + 0.02 0.04 + 0.025 0.05 + 0.025 0.002 + 0.003 1 mA 0.007 + 0.005 0.030 + 0.005 0.05 + 0.005 0.002 + 0.0005 10 mA 0.007 + 0.02 0.03 + 0.02 0.05 + 0.02 0.002 + 0.002 100 mA 0.01 + 0.004 0.03 + 0.005 0.05 + 0.005 0.002 + 0.0005
[2]
1 A
0.03 + 0.02 0.04 + 0.02 0.05 + 0.02 0.005 + 0.001
[1][2]
3 A
0.05 + 0.02 0.08 + 0.02 0.1 + 0.02 0.005 + 0.002
[2]
10 A
0.1 + 0.008 0.12 + 0.008 0.15 + 0.008 0.005 + 0.0008
[1] Part of 10 A range [2] Available at front panel connectors only
Accuracy (8845A)
Accuracy is given as ± (% measurement + % of range)
Range
100 µA 0.01 + 0.02 0.04 + 0.025 0.05 + 0.025 0.002 + 0.003 1 mA 0.007 + 0.005 0.030 + 0.005 0.05 + 0.005 0.002 + 0.0005 10 mA 0.007 + 0.02 0.03 + 0.02 0.05 + 0.02 0.002 + 0.002 100 mA 0.01 + 0.004 0.03 + 0.005 0.05 + 0.005 0.002 + 0.0005
[2]
1 A
0.03 + 0.04 0.08 + 0.02 0.05 + 0.02 0.005 + 0.001
[1][2]
3 A
0.05 + 0.08 0.12 + 0.02 0.1 + 0.02 0.005 + 0.002
[2]
10 A
0.1 + 0.008 0.12 + 0.008 0.15 + 0.02 0.005 + 0.0008
[1] Part of 10 A range [2] Available at front panel connectors only
Additional Current Errors
Digits NPLC Additional Noise Error
100 0 % of range 6½ 10 0 % of range 5½ 1 0.001 % of range 5½ 0.2 0.001 % of range ± 4 μA 0.02 0.01 % of range ± 4 μA
24 Hour
(23 ± 1 °C)
24 Hour
(23 ± 1 °C)
Resolution
90 Days
(23 ± 5 °C)
90 Days
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Shunt Resistance
(Ohms)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Burden Voltage
6 Fluke Corporation 8845A and 8846A
Page 8
AC Current
The following ac current specifications are for sinusoidal signals with amplitudes greater than 5 % of range. For inputs from 1% to 5 % of range, add an additional error of 0.1 % of range.
Input Protection............................................................Tool accessible 11 A/1000 V and 440 mA/1000 V fuses.
Measurement Method..................................................ac-coupled true-rms, dc-coupled to the fuse and shunt (no blocking capacitor)
AC Filter Bandwidth
Slow.............................................................................3 Hz to 10 kHz
Medium.......................................................................20 Hz to 10 kHz
Fast..............................................................................200 Hz to 10 kHz
Maximum Crest Factor................................................5:1 at full scale
Additional Crest Factor Errors (<100 Hz) ..............Crest Factor 1-2, 0.05 % of full scale
Input Characteristics
Range
100 μA 1 mA 10 mA 10.00000 mA 1 μA 100 nA 10 nA 1 Ω <0.025 V 100 mA 100.0000 mA 10 µA 1 μA 100 nA 1 Ω <0.25 V 1 A 1.000000 A 100 µA 10 µA 1 μA 0.01 Ω <0.05 V 3 A[2] 3.00000 A 1 mA 100 µA 10 μA 0.01 Ω <0.05 V 10 A 10.00000 A 1 mA 100 µA 10 µA 0.01 Ω <0.5 V
[1] 8846A Only [2] Part of 10 A range
Full Scale
(6½ Digits)
[1]
100.0000 μA 10 nA 1 nA 100 pA 100Ω <0.015 V
[1]
1.000000 mA 100 nA 10 nA 1 nA 100Ω <0.15 V
4½ Digits 5½ Digits 6½ Digits
8846A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range
100 μA
Frequency
(Hz)
3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006 5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006 5 – 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.006
1 mA
3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006 5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006 5 – 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.006
10 mA
3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006 5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1+ 0.04 0.015 + 0.006 5 – 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.006
100 mA
3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006 5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006
1 A
[2]
5 – 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.006 3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006 5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006
3 A
[1][2]
5 – 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.006 3 – 5 Hz 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.1 + 0.006 5 – 10 Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.035 + 0.006 10 Hz – 5 kHz 0.5 + 0.7 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006
10 A
[2]
5 – 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.006 3 – 5 Hz 2.0 + 0.06 2.0 + 0.06 2.0 + 0.06 0.2 + 0.006 5 – 10 Hz 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.1 + 0.006 10 Hz – 5 kHz 0.15 + 0.06 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006 5 – 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.006
[1] Part of 10 A range [2] Available only on front panel connectors
24 Hour
(23 ± 1 °C)
Crest Factor 2-3, 0.2 % of full scale Crest Factor 3-4, 0.4 % of full scale Crest Factor 4-5, 0.5 % of full scale
Resolution
90 Days
(23 ± 5 °C)
Shunt Resistance
(Ohms)
1 Year
(23 ± 5 °C)
Burden Voltage
Temperature
Coefficient/ °C
Outside 18 to 28 °C
8845A and 8846A Fluke Corporation 7
Page 9
8845A Accuracy
Accuracy is given as ± (% measurement + % of range)
Range
10 mA
Frequency
(Hz)
3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1+ 0.04 0.015 + 0.006 5 – 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.006
100 mA
3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006 5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006
1 A
[2]
5 – 10 kHz 0.2 + 0.25 0.2 + 0.25 0.2 + 0.25 0.03 + 0.006 3 – 5 Hz 1.0 + 0.04 1.0 + 0.04 1.0 + 0.04 0.1 + 0.006 5 – 10 Hz 0.3 + 0.04 0.3 + 0.04 0.3 + 0.04 0.035 + 0.006 10 Hz – 5 kHz 0.1 + 0.04 0.1 + 0.04 0.1 + 0.04 0.015 + 0.006
3 A
[1][2]
5 – 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.006 3 – 5 Hz 1.1 + 0.06 1.1 + 0.06 1.1 + 0.06 0.1 + 0.006 5 – 10 Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.035 + 0.006 10 Hz – 5 kHz 0.15 + 0.06 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006
10 A
[2]
5 – 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.006 3 – 5 Hz 1.1 + 0.04 1.1 + 0.04 1.1 + 0.04 0.2 + 0.006 5 – 10 Hz 0.35 + 0.04 0.35 + 0.04 0.35 + 0.04 0.1 + 0.006 10 Hz – 5 kHz 0.15 + 0.04 0.15 + 0.04 0.15 + 0.04 0.015 + 0.006 5 – 10 kHz 0.35 + 0.7 0.35 + 0.7 0.35 + 0.7 0.03 + 0.006
[1] Part of the 10 A range [2] Available only at front panel connectors
Additional Low Frequency Errors
Error is stated as % of reading.
Frequency
3HZ (slow) 20HZ (medium) 200HZ (fast)
AC Filter
10 – 20 Hz 0 0.25 – 20 – 40 Hz 0 0.02 – 40 – 100 Hz 0 0.01 0.55 100 – 200 Hz 0 0 0.2 200 Hz – 1 kHz 0 0 0.02 > 1 kHz 0 0 0
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Frequency
Gate Times.....................................................................Programmable to 1 s, 100 ms, and 10 ms.
Measurement Method..................................................Flexible counting technique. AC-coupled input using the ac voltage measurement
Settling Considerations..............................................When measuring frequency or period after a dc offset voltage change, errors may occur.
Measurement Considerations....................................To minimize measurement errors, shield inputs from external noise when measuring low-
8846A Accuracy
Accuracy is given as ± % measurement
Range Frequency
100 mV to 1000 V
3 – 5 Hz 0.1 0.1 0.1 0.005
[1][2]
5 – 10 Hz 0.05 0.05 0.05 0.005 10 – 40 Hz 0.03 0.03 0.03 0.001 40 Hz – 300 kHz 0.006 0.01 0.01 0.001 300 kHz – 1 MHz 0.006 0.01 0.01 0.001
[1] Input >100 mV. For 10 – 100 mV, multiply percent measurement error by 10. [2] Limited to 8 X 10
8 Fluke Corporation 8845A and 8846A
7
volt-Hertz
24 Hour
(23 ± 1 °C)
function.
For the most accurate measurement, wait up to 1 second for the input blocking capacitor to settle.
voltage, low-frequency signals.
90 Days
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Page 10
8845A Accuracy
Accuracy is given as ± % measurement
Range Frequency
100 mV to 750 V
3 – 5 Hz 0.1 0.1 0.1 0.005
[1][2]
5 – 10 Hz 0.05 0.05 0.05 0.005
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Compensation/ °C
Outside 18 to 28 °C
10 – 40 Hz 0.03 0.03 0.03 0.001 40 Hz – 300 kHz 0.006 0.01 0.01 0.001
[1] Input >100 mV. For 10 – 100 mV, multiply percent measurement error by 10. [2] Limited to 8 X 10
7
volt-Hertz
Gate Time vs. Resolution
Gate Time Resolution
0.01 5½
0.1 6½
1.0 6½
Additional Low Frequency Errors
Error stated as percent of measurement for inputs >100 mV. For 10 – 100 mV, multiply percent by 10.
Frequency
6½ 5½ 4½
3 – 5 Hz 0 0.12 0.12 5 – 10 Hz 0 0.17 0.17 10 – 40 Hz 0 0.2 0.2 40 – 100 Hz 0 0.06 0.21 100 – 300 Hz 0 0.03 0.21 300 Hz – 1 kHz 0 0.01 0.07 > 1 kHz 0 0 0.02
Resolution
Capacitance (8846A Only)
Accuracy is stated as ±(% of measurement + % of range)
Range Resolution
1 Year Accuracy
(23 ± 5 °C)
1 nF 1 pF 2% ± 2.5 % 0.05 + 0.05 10 nF 10 pF 1% ± 0.5 % 0.05 + 0.01 100 nF 100 pF 1% ± 0.5 % 0.01 + 0.01 1 µF 1 nF 1% ± 0.5 % 0.01 + 0.01 10 µF 10 nF 1% ± 0.5 % 0.01 + 0.01 100 µF 100 nF 1% ± 0.5 % 0.01 + 0.01 1 mF 1 µF 1% ± 0.5 % 0.01 + 0.01 10 mF 10 µF 1% ± 0.5 % 0.01 + 0.01 100 mF 100 µF 4% ± 0.2 % 0.05 + 0.05
[1] Stated accuracy is attained when Zero function is used.
[1]
Temperature Coefficient/ °C
Outside 18 to 28 °C
Temperature (8846A only)
Test Current...................................................................1 mA
Accuracy is stated as ± °C and is based on a Platinum RT100 (DIN IEC 751, 385 type) RTD with less than 10 ohms lead resistance. Specifications do not include probe accuracy, which must be added.
Range Resolution
90 Days
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
-200 °C 0.001 °C 0.06 0.09 0.0025
-100 °C 0.001 °C 0.05 0.08 0.002 0 °C 0.001 °C 0.04 0.06 0.002
100 °C 0.001 °C 0.05 0.08 0.002
300 °C 0.001 °C 0.1 0.12 0.002
600 °C 0.001 °C 0.12 0.14 0.002
Accuracy
Temperature
Coefficient/ °C
Outside 18 to 28 °C
8845A and 8846A Fluke Corporation 9
Page 11
Continuity
Continuity Threshold ..................................................Selectable between 1 Ω and 1000 Ω
Test Current...................................................................1 mA
Response Time..............................................................300 samples/sec with audible tone
Accuracy is given as ± (% measurements + % of range)
Range
1000.0 Ω 0.002 + 0.01 0.008 + 0.02 0.01 + 0.02 0.001 + 0.002
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Diode Test
Test Current...................................................................100 μA or 1 mA
Response Time..............................................................300 samples/sec with audible tone.
Accuracy is given as ± (% measurements + % of range)
Range
5.0000 V 0.002 + 0.002 0.008 + 0.002 0.01 + 0.002 0.001 + 0.002
10.0000 V 0.002 + 0.001 0.008 + 0.002 0.01 + 0.002 0.001 + 0.002
24 Hour
(23 ± 1 °C)
90 Days
(23 ± 5 °C)
1 Year
(23 ± 5 °C)
Temperature
Coefficient/ °C
Outside 18 to 28 °C
Measurement Rates
Function Digits Setting
DC Volts, DC Current, and Resistance
AC Voltage and AC Current
Frequency and Period
[1] Typical measurement rates with autozero off. [2] Maximum measurement rates for 0.01 % of ac step. When dc input varies, additional settling delay is required. [3] For remote operation or external trigger using default settling delay [4] Settling delay = 0
[2]
100 NPLC 1.67 (2) s 0.6 (0.5) 0.6 (0.5) 6½ 10 NPLC 167 (200) ms 6 (5) 6 (5) 5½ 10 NPLC 16.7 (20) ms 60 (50) 60 (50) 5½ 0.2 NPLC 3 ms 300 300 6½ 3 Hz 0.14 0.14 6½ 20 Hz 1 1 6½ 200 Hz 6½ 200 Hz 6½ 1 s 1 1 5½ 100 ms 9.8 9.8 4½ 10 ms 80 80
Integration Time
60 Hz (50 Hz)
[3]
1.6 1.6
[4]
6 6
Measurements/Second
8845A 8846A
[1]
10 Fluke Corporation 8845A and 8846A
Page 12
Fluke. Keeping your world
up and running.
Fluke Corporation PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 8/2006 2748044 D-EN-N Rev A Pub_ID: 11152-eng Rev 01