Fluke 805 Data Sheet

Fluke 805
Vibration Meter
Now compatible with Fluke Connect
The reliable, repeatable, accurate way to check bearings and overall vibration.
Make go or no-go maintenance decisions with confidence. The Fluke 805 Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall
vibration and bearing condition
What makes the Fluke 805 the most reliable vibration screening device available?
Innovative sensor design minimizes measure­ment variations caused by device angle or contact pressure
Consistent data quality at both low and high frequency ranges
Four-level severity scale assesses urgency of prob­lems for overall vibration and bearing condition
Exportable data via USB
Trending in Microsoft® Excel using built-in
templates
Overall vibration measurement (10 Hz to 1,000 Hz) for acceleration, velocity and displacement units of measurement for a wide variety of machines
Crest Factor+ technology provides reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
Compare vibration levels with ISO-10816 severity scales and store results to the Fluke Connect Cloud
Get authorization to take next steps in an instant if machine health is at risk via Fluke Connect™ Share­Live video call
Colored lighting system (green, red) and on-screen comments indicate how much pressure needs to be applied to take measurements
Temperature measurement with Spot IR Sensor increases diagnostic capabilities
On-board memory holds and saves up to 3,500 measurements
External accelerometer support for hard to reach locations
Flashlight for viewing measurement locations in dark areas
Large screen with high resolution for easy naviga­tion and viewing
™ Mobile App
Technical Data
Built with
See it. Save it. Share it. All the facts, right in the field.
Fluke Connect with ShareLive™ is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is available for Android™ (4.3 and up) and iOS (4s and later) and works with over 20 different Fluke products—the largest suite of connected test tools in the world. And more are on the way. Go to the Fluke website to find out more.
Make the best decisions faster than ever before by viewing all temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Download the app at:
Smart phone not included with purchase.
What is Crest Factor +?
What is Crest Factor +?
Fluke 805 with Crest Factor + takes the confusion out of bearing assessment
The original Crest Factor is used by vibration analysts to identify bearing faults. It is defined as the ratio of the peak value/RMS value of a time domain vibration signal.
A key limitation of using Crest Factor to identify bearing faults is that the Crest Factor does not increase linearly as the bearing degrades. In fact, the Crest Factor can actually decrease as a bearing nears cata­strophic failure due to large RMS values.
In order to overcome this limitation, Fluke uses a proprietary algorithm known as Crest Factor + (CF+). CF+ values range from 1 to 16. As the bearing condition worsens, the CF+ value increases. To keep things simple, Fluke has also included a four-level severity scale that identifies the bearing health as Good, Satisfactory, Unsatisfactory or Unacceptable.
High Frequency
4,000 Hz to 20,000 Hz
Overall Vibration
Frequency Range
10 Hz to 1,000 Hz
Temperature
-20 °C to 200 °C
Bearing Vibration (CF+)
Overall Vibration
IR Temperature
Exporting and Trending
with the 805
Export and Trend in Excel
Trending, or repeated vibration measurements kept in a spreadsheet over time, is the best method to track machine health. With 805 you can easily:
Export your result to Excel through USB connection
Trend the readings with the pre-built Excel
templates and plot graphs
Compare the overall vibration readings to ISO
Standards (10816-1, 10816-3, 10816-7)
Import measurements from the 805 Vibration Meter to an Excel template on your PC in order to trend the bearing parameters: overall vibration, CF+, and temperature. Looking at just the number alone for the overall vibration or temperature might not be of much benefit to the operator or technician if they don’t know what the number means. The user may not know what is normal or what indicates a problem.
If measurements taken on the operator rounds are easily loaded into Excel, then the trend will show patterns of something that is becoming abnormal. The user can now see a clear picture of the changing bearing condition and deteriorating health of the machine.
Sample trend plot using the Fluke 805 trending template.
2 Fluke Corporation Fluke 805 Vibration Meter
Use the Fluke 805 Vibration Meter to
check these machine categories:
Chiller (refrigeration)
Reciprocating (Open motor and compressor
separate)
Reciprocating (Hermetic motor and compressor)
Centrifugal (Hermetic or Open Motor
Fans
Belt-driven Fans 1800 to 3600 RPM
Belt-driven fans 600 to 1799 RPM
General direct drive fans (direct coupled)
Vacuum blowers (belt or direct drive)
Large forced draft fans (fluid film brgs.)
Large induced draft fans (fluid film brgs.)
Shaft-mounted intergral fan (extended motor shaft)
Axial flow fans (belt or direct drive)
Cooling tower drives
Long, hollow drive shaft (motor)
Belt drive (motor and fan - all arrangements)
Direct drive (motor and fan - all arrangemetns
Centrifugal Pumps
Note: height is measured from grade to top motor bearing
Vertical pumps (12’ to 20’ height)
Vertical pumps (8’ to 12’ height)
Vertical pumps (5’ to 8’ height)
Vertical pumps (0’ to 5’ height)
Horizontal centrifugal end suction pumps – direct
coupled
Horizontal centrifugal double suction pumps – direct coupled
Boiler feed pumps (turbine or motor driven)
Positive Displacement Pumps
Positive displacement horizontal piston pumps (under load)
Positive displacement horizontal gear pumps (under load)
Air compressors
Reciprocating
Rotary screw
Centrifugal with or without external gearbox
Centrifugal – internal gear (axial meas.)
Centrifugal – internal gear (radial meas.)
Blowers
Lobe-type rotary blowers (belt or direct drive)
Multi-stage centrifugal blowers (direct drive)
Generic gearboxes (rolling element bearings)
Single stage gearbox
Machine tools
Motor
Gearbox input
Gearbox output
Spindles – roughing operations
Spindles – machine finishing
Spindles – critical finishing
3 Fluke Corporation Fluke 805 Vibration Meter
Technical specifications
Vibration meter
Low frequency range
10 Hz to 1,000 Hz
(overall measurement) High frequency range
4,000 Hz to 20,000 Hz
(CF+ measurement) Severity levels Good, Satisfactory, Unsatisfactory,
Unacceptable Vibration limit 50 g peak (100 g peak-peak) A/D converter 16-bit Signal to noise ratio 80 dB Sampling rate  Low frequency 20,000 Hz High frequency 80,000 Hz Real time clock backup Coin battery
Sensor
Sensitivity 100 mV / g ± 10% Measurement range 0.01 g to 50 g Low frequency range
10 Hz to 1,000 Hz (overall measurement)
High frequency range
4,000 Hz to 20,000 Hz (CF+ measurement)
Resolution 0.01 g Accuracy At 100 Hz ± 5 % of measured value
Amplitude units
Acceleration g, m/sec
2
Velocity in/sec, mm/sec Displacement mils, mm
Infrared thermometer (temperature measurement)
Range -20 °C to 200 °C (-4 °F to 392 °F) Accuracy ±2 °C (4 °F) Focal length Fixed, at ~3.8 cm (1.5″)
External sensor
Note: Fluke supports, but does not provide, external sensors.
Frequency range 10 Hz to 1,000 Hz Bias voltage (to supply power) 20 V dc to 22 V dc Bias Current (to supply power) Maximum 5 mA
Firmware
Calibration Factory calibration required External interfaces USB 2.0 (full speed) communication Data capacity Database on internal flash memory Upgrade through USB Memory Up to 3,500 measurements
Radiated emission
Electrostatic discharge: Burst Standard EN 61000-4-2 Electromagnetic interference Standard EN 61000-4-3 RE Standard CISPR 11, Class A
(RF connection time (binding time) can take up to 1 minute.)
Environmental
Operating
-20 °C to 50 °C (-4 °F to 122 °F)
temperature Storage
-30 °C to 80 °C (-22 °F to 176 °F)
temperature Operating
humidity Operating/
Storage altitude
10 % to 95 % RH (non-condensing)
Sea Level to 3,048 meters
(10,000 feet) IP rating IP54 Vibration limit 500 g peak Drop test 1 meter
General specifications
Battery type AA (2)Lithium Iron Disulfide Battery life 250 measurements Size (L x W x H) 25.72 cm x 16.19 cm x 9.84 cm
(10.13 in x 6.38 in x 3.875 in) Weight 1.16 kg (2.55 lb) Fluke Connect™
mobile app
Yes compatible
Connectors USB mini-B 7-pin, external sensor
jack (SMB connector)
Ordering information
Fluke-805 FC Vibration Meter
Includes: 805 FC Vibration Meter, USB cable, storage case, belt holster, quick reference guide, CD-ROM (includes MS Excel template and documentation), and four AA batteries
Fluke. Keeping your world up and running.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2012, 2014 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 3/2014 6002302B_EN
Modification of this document is not permitted without written permission from Fluke Corporation.
®
4 Fluke Corporation Fluke 805 Vibration Meter