Fluke 725 User Manual

5
A
UNCLASSIFIED AREA OR AREAS CLASSIFIED AS ZONE 0 OR CLASS I, DIV 1, GROUPS B, C, D
THE CONNECTIONS SHOWN FOR J1-J6 JACKS CAN BE USED SIMULTANEOUSLY WITH ANY
D D
CONNECTION SHOWN FOR J7-J8 JACKS
W
ONLY CONNECTIONS SPECIFIED ON THIS DRAWING ARE ALLOWED. OTHER CONNECTIONS MAY INVALIDATE INTRINSIC SAFETY
FLUKE 725Ex
C C
J1
J2J3J4J5J6J7J8
FLUKE 725Ex
B B
J3 J7
J1
J5
J4
J8J2
J6
FLUKE 725Ex
A A
J3
J1
J4
J2
J7
J5
J8
J6
5
Measure mA
Simulate mA
Approved Associated
+
Apparatus
-
Simple Apparatus
+
Approved Intrinsically Safe Apparatus
-
Source mA
Simple Apparatus
+
Approved Intrinsically Safe Apparatus
-
Measure V, Frequency
Approved Associated Apparatus
+
Approved Intrinsically Safe Apparatus
-
or
or
or
4
FLUKE 725Ex
J3
J1
J6J5J8
J2
J4
FLUKE 725Ex
J3
J5
J4 J6
J2
FLUKE 725Ex
J1
J3
J5
J6J2
J4
FLUKE 725Ex
J3
J1
J5
J2
J4
4
Source V, Frequency, RTD (Ohms)
J7
Measure RTD (Ohms) 2,3,4 Wire Mode
4W
J7J1
J8
2W
2W 3W
Measure Thermocouple
J7
J8
Source Thermocouple
J7
J8J6
Approved Associated
or
Apparatus
+
Approved Intrinsically Safe Apparatus
-
Connections
Mode
used
2 Wire
2 W ONLY
3 Wire
2 W and 3 W
4 Wire
2 W,3 W and 4 W
Simple Apparatus
+
Approved Intrinsically Safe Apparatus
-
Simple Apparatus
+
Approved Intrinsically Safe Apparatus
-
Simple Apparatus
+
Approved Intrinsically Safe Apparatus
-
3
FLUKE 725Ex
Measure mA feedback
2
Fluke 725Ex Multi function
1
Calibrator
CSA: IS Class I; Div 1; Groups B-D T = 171 ºC
AEx ia IIB, T = 171 ºC
Approved Associated Apparatus
J1 J3
J4
J2
FLUKE 725Ex
J3J1
J2
or
J4
FLUKE 725Ex
J3
J1
J2
or
J4
J5
J6
J5
J6
J6J5J8
J7
J8
J7
J8
J7
+
Input
-
Measure mA feedback while providing power to the loop
+
Input
-
Measure V using J7-J8
+
-
Fluke 700PEx pressure module only
FLUKE 725Ex
or
J1J2J3
J4J5J6J7J8
3
Pressure Mode
THE PRESSURE MODULE CAN BE USED SIMULTANEOUSLY WITH ANY CONNECTION SHOWN ON THIS DIAGRAM FOR J1-J8 JACKS
+-
Loop
-
+
Simple Apparatus Approved Intrinsically
Safe Apparatus
Loop
-
+
Simple Apparatus Approved Intrinsically
Safe Apparatus
jacks
Approved Associated Apparatus
or
Approved Intrinsically Safe Apparatus
2
Ta = -10 ºC... +55 ºC
ENTITY PARAMETERS:
Input Entity Parameters:
All Inputs: J1-J2, J3-J4, J5-J6, J7-J8:
Ui = 30 V, Ii = 100 mA Pi = 750 mW, Li = 0 mH
J1-J2: Ci = 0.01 µF
or
J3-J4: Ci = 0 µF J5-J6: Ci = 0.01 µF J7-J8: Ci = 0 µF
Output Entity Parameters:
J1-J2: Uo = 13.7 V, Io = 96.5 mA, Po = 331 mW
J3-J4: Uo = 13.6 V, Io = 25.2 mA, Po = 86 mW
J5-J6: Uo = 13.7 V, Io = 26 m A, Po = 90 mW
J7-J8: Uo = 13.7 V, Io = 76 mA, Po = 261 mW
Co (
Terminals
Grp B IIB, Grp C IIA, Grp D Grp B IIB, Grp C IIA, Grp D
J1-J2 1.0 5.0 18.1 4.0 16.0 32.0
J3-J4 1.0 5.2 18.6 50.0 200.0 400.0
J5-J6 1.0 5.0 18.1 50.0 200.0 400.0 J7-J8 1.0 5.0 18.1 6.1 22.0 45.0
or
:
NOTES
1. Connections to an Intrinsically Safe Apparatus/Associated Apparatus/Loop must be in acordance
2. Intrinsic Safety Entity Concept: The Intrinsic Safety Entity Concept allows the interconnection of two or more Approved Intrinsically Safe devices or Associated Apparatus with entity parameters not specifically examined in combination as a system when: Uo or Voc or Vt <= Vmax or Ui
Io or Isc or It <= Imax or Ii Ca or Co >= Ci + Ccable La or Lo >= Li + Lcable Po <= Pi
3. Installation must be in accordance with Article 500 or Article
505 of the NEC (ANSI/NFPA70) and ANSI/ISA RP12.6 or equivalent. Installation in Canada should be in accordance with the Canadian Electrical Code, CSA C22.1, Part I.
4. The Fluke 725Ex Multifunction Calibrator may only be connected to terminals with compatible entity parameters except as indicated in Note 2 and must not be connected to internal circuitry of Associated Apparatus or Intrinsically Safe Apparatus. Failure to comply with this rule violates approval.
5. Applying more than 30 V or 100 mA to the input terminals invalidates the Calibrator's Ex Approval and may damage the unit. Immediately remove the unit from the Ex-
hazardous area and contact a Fluke Service Center. Control equipment connected to the Associated Apparatus must not use or generate more than 250 Vrms or Vdc.
6. Examples of a simple apparatus are switch, TC, RTD and connector.
7. Refer to the 725Ex User Manual (provided on the CD) for additional safety information.
8. No revision to this drawing is permitted without approval from CSA and KEMA
µF)
with notes 2 thru 5
Rev Description
12345
SCALE: None Sheet 1 of 1
Rev Description By Date
B5
Original
Fluke 700Pex CCD
Fluke 725Ex CCD
Fluke Part Number: XXXXXXXXXX
Fluke Part Number: 2117036
MARTEL 6800032
1
Lo (mH
)
Nov. 18, 2003
ug. 24, 2004