Fluke 43B, 345 Data Sheet

Fluke 43B Power Quality Analyzer
Maintain power systems, troubleshoot power problems, diagnose equipment failures
The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems, troubleshoot power problems and diagnose equipment failures. All in a rugged handheld package.
operating time of 6.5 hours Combines the most useful capabilities of a
power quality analyzer, multimeter and scope Calculates 3-phase power on balanc
from a single-phase measurement Trends voltage, current, frequency, power
harmonics and captures voltage sags, transients and inrush current Monitoring functions help track intermittent
problems and power system performance Records two selectable parameters for up
to 16 days 20 measurement memories to save/recall
screens and data with cursor readings FlukeView®Software can log harmonics
and all other readings over time and provides a complete harmonics profile up to the
st
harmonic
51 Measures resistance, diode voltage drop,
continuity, and capacitance Users/applications manual and power quality
video to help answer tough questions Complete package with voltage probes and
400 A current clamp, FlukeView Software and optically isolated interface cable 3 year warranty on the Fluke 43B, 1 year on
accessories
ed loads,
On screen graphics show you how to set up
3-phase power measurements
atts, power factor, displac
W
factor (Cos φ), VA and VAR Voltage and current waveforms
ement power
Voltage and current waveforms
True-rms voltage and current
Frequenc
y
Voltage, current, and power harmonics
Up to 51st harmonic
otal harmonic distortion (T
T
Phase angle of individual harmonics
HD)
Specifications
• Measurements are always automatically recorded to instantly show changes over time
• Use cursors to read time and date of sags and swells
• Catch voltage transients and waveform distortion down to 40 nS
• Catch and save up to 40 transients
• Correlate the cause of transients with time and date stamps
Accuracies are stated as ± (percentage of reading + counts) without probes unless
Specifications are valid for signals with a fundamental between 40 and 70 Hz.
otherwise noted.
Input Characteristics Ranges Accuracy
Input impedance 1 M, 20 pF Voltage rating 600 Vrms, CAT III
Volt/Amps/Hertz
True-rms voltage (AC+DC) 5.000 V, 50.00 V, 500.0 V, 1250 V* ± (1 % + 10 counts) True-rms current (AC+DC) 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA ± (1 % + 10 counts) Frequency 10.0 Hz to 15.0 kHz ± (0.5 % + 2 counts) CF Crest Factor 1.0 to 10.0 ± (5 % + 1 count)
Power
W, VA, VAR Reactive Power 250 W 2.50 kW, 25.0 kW, 250kW, 2.50 MW, ± (2 % + 6 counts) Total Power 1-phase and 3-phase, 3 25 MW, 250 MW, 625 MW, 1.56 GW ± (4 % + 4 counts) Fundamental conductor balanced loads Power
PF Power Factor 0.00 to 1.00 ± 0.04 DPF Displacement Power Factor 0.00 to 0.25 not specified
Hz Frequency fundamental 40.0 to 70.0 Hz ± (0.5 % + 2 counts)
Harmonics
Volts, Amps, Watts Fundamental V, A ± (3 % + 2 counts),
Frequency of fundamental 40 Hz to 70 Hz ± 0.25 Hz Phase Volt & Amps (between Fund. & Harmonic) 2nd (± 3°) … 51st (± 15°)
K-Factor (Amps & Watts) 1.0 to 30.0 ± 10 % THD 0.00 to 99.99 ± (3% + 8 counts)
Sags & Swells
Recording times (selectable) 4 min to 16 days Vrms actual, Vrms max, 5.000 V, 50.00 V 500.0 V, 1250 V* Readings ± (2 % +10 counts)
min (AC + DC) Cursor readings ± (2 % + 12 counts)
Arms actual, Arms max, 50.00 A, 500.0 A, 5.000 kA, 50,00 kA min (AC + DC)
Recording
ording times (selectable)
Rec
arameters
P
V/A/Hz Line Voltage, Current, Frequency Power Watts, VA, VAR, PF, DPF, Frequency Harmonics THD, Volts (Fund. & Harmonic), Amps(F&H) Watts(F&H) Freq.(H), %(H) of total, Phase(H), KF Ohms Ohms, Diode, Continuity, Capacitance Temperature °C or °F Scope DC Voltage, DC Current, AC Voltage, AC Current, Frequency, Pulse Width + or -,
ansients
Tr
Minimum pulse w Useful bandw
er of transients
Numb
oltage threshold settings
V Referenc
Vpeak min, Vpeak max at cursor 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V ± 5 % of full scale
e sig
idth
idth input
nal
0.25 to 0.90 ± 0.04
0.90 to 1.00 ± 0.03
2 to 31st Harmonic V, A ± (5 % + 3 counts),
32 to 51st Harmonic V, A ± (15 % + 5 counts),
Watts (between Volt Fund. & Amps Harmonic ) Fund (± 5°) … 51st (± 15°)
6 days
4 min to 1 Choose one or two parameters from one of the g
eak min, P
Phase, Duty c
40 ns
C to 1 M
D 40 20 %, 50 %, 1 After S
data a pure sinewave is calculated as reference for threshold setting.
ycle + or -, P
Hz (w
00 %, 200 % ab
ART, the Vrms and frequency of the signal are measured. From these
T
eak max, P
ith test leads TL24)
ove or b
elow reference signal
W ± (5 % + 2 counts)
W ± (10 % + 10 counts)
W ± (30 % + 5 counts)
Cursor Readings Average ± (2 % +10 counts)
roups below
eak min-max, Crest F
actor
*Rated 600 V CAT II