Fluke 335 Technical Data

Page 1
Fluke 320 and 330 Series Clamp Meters
Narrow body and jaw fit into small spaces
Backlight available on most models
Accurate low current measurements
Inrush current feature on most models
Auto shut-off
New Inrush Feature
A new innovation from Fluke! Fluke Clamp Meters with the inrush feature measure motor starting current like a circuit breaker or overload unit sees it. One button lets you troubleshoot current surges that can cause nuisance tripping. Fluke’s inrush feature gives you a synchronized reading of the current draw profile from motor start up.
For more information about Fluke’s new inrush feature go to www.fluke.com/330 to view Inrush, A Technology Brief.
Page 2
321 322
AC Amps AC Amps Ohms Ohms AC Volts AC Volts Auto-Off Auto-Off Hold Hold Compact Compact
DC Volts
Measure ac current 400.0 A
40.00 A
400.0 A
Measure ac voltage
400.0 V 400.0 V 600 V 600 V
Measure continuity ≤ 30 Ω≤30
Measure dc voltage
400.0 V 600 V
Higher resolution for loads below 40 amperes
0 - 40.00A
40.0 - 400.0A Measure resistance 400.0 400.0 Ω Measure inrush Work in poorly lit areas Measure non-linear loads Measure dc current Variable speed drives and stand-by power
Choose the model that fits your work.
Looking for a clamp meter that’s right for you? Match the functions and features listed below to the Fluke Clamp Meter best suited for your job.
Page 3
333 334 335 336 337
AC Amps AC Amps AC Amps AC Amps AC Amps Ohms Ohms Ohms Ohms Ohms AC Volts AC Volts AC Volts AC Volts AC Volts Auto-Off Auto-Off Auto-Off Auto-Off Auto-Off Hold Hold Hold Hold Hold Full Size Full Size Full Size Full Size Full Size DC Volts DC Volts DC Volts DC Volts DC Volts
In-rush In-rush In-rush In-rush Backlight Backlight Backlight Backlight
True-rms True-rms True-rms
DC Amps DC Amps
Frequency Large Jaw MIN/MAX
400.0 A 600.0 A 600.0 A 600.0 A 999.9 A
600.0 V 600.0 V 600.0 V 600.0 V 600.0 V
30 Ω≤30 Ω≤30 Ω≤30 Ω≤30
600.0 V 600.0 V 600.0 V 600.0 V 600.0 V
600.0 6000 6000 6000 6000 100 mS 100 mS 100 mS 100 mS Backlight Backlight Backlight Backlight
True-rms True-rms True-rms
600.0 A 999.9 A
400.0 Hz
Page 4
Fluke 321 Fluke 322 Fluke 333 Fluke 334 Fluke 335 Fluke 336 Fluke 337
Range 0 - 400.0 A 0 - 40.00 A 0 - 400.0 A 0 - 600.0 A 0 - 600.0 A 0 - 600.0 A 0 - 999.9 A
40.0 - 400.0 A
Accuracy 1.8% ± 5 counts 1.8% ± 5 counts 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts
(50 - 60 Hz) (50 - 60 Hz) (50 - 60 Hz) (50 - 60 Hz) (50 - 60 Hz) (10 - 100 Hz) (10 - 100 Hz)
3.0% ± 5 counts 3.0% ± 5 counts 6% ± 5 counts 6% ± 5 counts (60 Hz - 400 Hz) (60 Hz - 400 Hz) (100 - 400 Hz) (100 - 400 Hz)
Crest Factor ————2.4 @ 500 A3 @ 500 A 3 @ 500 A (50/60 Hz) 2.0 @ 600 A 2.5 @ 600 A 2.5 @ 600 A
add 2% for C.F.>2 add 2% for C.F.>2 1.42 @ 1000 A
add 2% for C.F.>2
AC Response Averaging Averaging Averaging Averaging True-rms True-rms True-rms
Inrush Integration Time 100 mS 100 mS 100 mS 100 mS
Range —————0 - 600.0 A 0 - 999.9 A Accuracy —————2% + 3 counts 2% + 3 counts Range 0 - 400.0 V 0 - 400.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V
0 - 600 V 0 - 600 V
Accuracy 1.2% + 5 counts 1.2% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts
(50 - 400 Hz) (50 - 400 Hz) (50/60 Hz) (50/60 Hz) (50/60 Hz) (20 - 100 Hz) (20 - 100 Hz)
6% + 5 counts 6% + 5 counts
(100 - 400 Hz) (100 - 400 Hz) AC Response Averaging Averaging Averaging Averaging True-rms True-rms True-rms Range 0 - 400.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V
0 - 600 V Accuracy 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts Range 0 - 400.0 0 - 400.0 0 - 600.0 0 - 600.0 0 - 600.0 0 - 600.0 0 - 600.0
601 - 6000 601 - 6000 601 - 6000 601 - 6000
Accuracy 1% ± 5 counts 1% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts
Continuity 30 Ω≤30 Ω≤30 Ω≤30 Ω≤30 Ω≤30 Ω≤30
Range 5.0 - 400.0 Hz Accuracy ——————0.5% ±5 counts Trigger Level ——————10 - 100 Hz 5 A
5 - 10 Hz,
100 - 400 Hz 10 A
MIN/MAX No No No No No No Yes
Backlight No No No No Yes Yes Yes
Display Hold Yes Yes Yes Yes Yes Yes Yes
Height 7.5” 7.5” 9.375” 9.375” 9.375” 9.875” 9.875”
Size Width 2.5” 2.5” 3.125” 3.125” 3.125” 3.125” 3.125”
Depth 1.4” 1.4” 1.625” 1.625” 1.625” 1.625” 1.625” Jaw Opening 1” 1” 1.2” 1.2” 1.2” 1.7” 1.7”
Weight 8 oz. 8 oz. 11 oz. 11 oz. 11 oz. 11 oz. 11 oz.
Need Technical Assistance?
Call 1-800-44-FLUKE toll free in the U.S. or (800) 36-FLUKE in Canada or (425) 446-5500 in other countries.
Fluke Corporation
PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V.
PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries (425) 446-5500 or Fax (425) 446-5116 Web access: http://www.fluke.com/
©2001 Fluke Corporation. All rights reserved. Printed in U.S.A. 9/2001 1629613 D-ENG-N Rev A
Fluke. Keeping your world
up and running.
Models 333, 334, 335, 336 and 337
Operating temperature
-14 °F to 122 °F (-10 °C to 50 °C)
Altitude
2,500 meters
Battery life
(2) AA alkaline approximately 150 hours continuous, auto­matic low battery indicator
Safety rating
IEC 1010-2-031, 600 V CAT III
Temperature de-rating
Add 0.1 x specified accuracy for each ºC above 28 ºC or below 18 ºC
Storage temperature
-40 ºF to 140 ºF (-40 ºC to 60 ºC)
Warranty
Three years
Models 321 and 322
Operating temperature
-14 °F to 122 °F (-10 °C to 50 °C)
Altitude
2,000 meters
Battery life
(2) AAA carbon zinc approxi­mately 100 hours continuous, automatic low battery indicator
Safety rating
IEC 1010-2-031, 600 V CAT III
Temperature de-rating
< 18 °C, > 28 °C add 0.1 x specified accuracy / °C
Storage temperature
-22 °F to 140 °F (-30 °C to 60 °C)
Warranty
Two years
600V
CAT III
Designed and Conforms to
IEC 1010-2-031
Specifications (@23 ºC + 5 ºC RH 0 - 90%)