Fluke 323, 325 RMS, 324 RMS Brochure

Page 1
Four Things to Consider
Choose a clamp that gives accurate and repeatable results
Choose a clamp that gives accurate and repeatable results
Make sure the clamp meter works where you do
Make sure the clamp meter works where you do
Dont compromise on safety
Dont compromise on safety
When choosing features, pick quality over quantity
When choosing features, pick quality over quantity
When Buying a Clamp Meter
Does your clamp report the true-rms reading?
Is the problem with your motor or your clamp?
Make sure your clamp meter is working for you, not against you.
First, make sure your clamp meter reports the true-rms reading. Otherwise noise from everything including a variable frequency drive to compact fluorescent bulbs can result in a less accurate reading.
Have you ever dropped your clamp?
Do you use your clamp outside?
Ever used you clamp to pry apart wires?
If so, make sure you clamp can work where and how you do.
Making accurate and repeatable results in a laboratory is a good start. But you don’t always work in a clean and controlled environment. Before making a purchase, check whether the clamp is specified to work in the environment
you do.
Be sure you don’t buy a clamp specified for
indoor use only or with a minimum operating range warmer than 15 °F if you think you might need to make measurements outside. If
the clamp isn’t designed for the outdoors the
measurements you get might not be accurate.
Finally be sure the clamp you are using is rugged enough to continue to give reliable results after years of prying wires apart, drops from ladders and bouncing around the back of your truck.
Does the clamp have the correct rating for the work you are doing?
Can you use the meter easily when wearing personal protective equipment?
If the answer is no, you could be in danger.
Your test and measurement tools are a critical barrier between you and danger. They are quite literally an extension of your body into a very dangerous environment. First things first, be sure you choose a clamp meter with an appropriate category rating for the work you are doing.
Second, choose a brand with a reputation for providing safe and reliable test equipment. Anyone can buy a clamp meter and put their brand on it. Only a few manufacturers design, build and test their own equipment to exceed international safety standards.
Finally, your clamp meter is part of a safety system that includes personal protective equipment (PPE). In addition to having the right PPE, be sure that you can easily operate your test and measurement equipment with that gear in place.
©2013Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 10/2013 4230855B_EN
Modification of this document is not permitted without written permission from Fluke Corporation.
Not using all the features on your clamp meter?
If so, you could be wasting money and functionality.
These days you can get almost anything built into a clamp meter (tape measure anyone?). The more gadgets that are built into a clamp meter, the harder it becomes to use and the worse it performs. Instead of trying to get the most features possible, chose a meter that has the measurement functions you need to get the job done, without any of fluff that doesnt make sense. Plus, you don’t end up paying for features irrelevant to the job at hand.
Page 2
Fluke 320 Series
True-rms Clamp Meters
Fluke 320 Series
True-rms Clamp Meters
GO TO WORK
WITH THE
BEST.
GO TO WORK
WITH THE
BEST.
Big ac/dc features in a small form factor.
General electrical measurements with temperature and capacitance capabilities.
Fluke 323
The best option for general, grab-and-go troubleshooting needs.
Fluke 324 Fluke 325
Measurement capability:
400 A ac current measurement
600 V ac and dc voltage
measurement
True-rms ac voltage and current for accurate measurements on non-linear signals
Resistance measurement up to 4000 Ω with continuity detection
Features:
Slim, ergonomic design
CAT IV 300V/CAT III 600 V
safety rating
Hold button
Two-year warranty
Soft carrying case
Technical specifications
AC current Range Accuracy
400.0 A 2 % ± 5 digits (45 Hz to 65 Hz)
AC voltage Range Accuracy
DC voltage Range Accuracy
Resistance Range Accuracy
Continuity ≤ 70 Ω Data hold Yes Category rating CAT III 600 V, CAT IV 300 V
600.0 V 1.5 % ± 5 digits
600.0 V 1.0 % ± 5 digits
400.0 Ω 1.0 % ± 5 digits 4000 Ω
2.5 % ± 5 digits (65 Hz to 400 Hz)
Measurement capability:
400 A ac current measurement
600 V ac and dc voltage measurement
True-rms ac voltage and current
for accurate measurements on non-linear signals
Resistance measurement up to 4000 Ω with continuity detection
Temperature and capacitance measurement
Features:
Slim, ergonomic design
Backlight display
CAT IV 300V/CAT III 600 V
safety rating
Hold button
Two-year warranty
Soft carrying case
Technical specifications
AC current Range Accuracy
40.00 A 1.5 % ±5 digits (45 Hz to 400 Hz)
400.0 A
AC voltage Range Accuracy
600.0 V 1.5 % ± 5 digits
DC voltage Range Accuracy
600.0 V 1.0 % ± 5 digits
Resistance Range Accuracy
400.0 Ω 1.0 % ± 5 digits 4000 Ω
Continuity ≤ 30 Ω Capacitance 100.0 μF to 1000 μF Backlight Yes Data hold Yes Contact temperature -10.0 °C to 400.0 °C (14.0 °F to 752.0 °F) Category rating CAT III 600 V, CAT IV 300 V
Note: Add 2 % for position sensitivity.
Measurement capability:
400 A ac and dc current measurement
600 V ac and dc voltage measurement
True-rms ac voltage and current
for accurate measurements on non-linear signals
Resistance measurement up to 40 kΩ with continuity detection
Temperature and capacitance measurement
Frequency measurement
Min/Max functionality
Features:
Slim, ergonomic design
Backlight display
CAT IV 300V/CAT III 600 V
safety rating
Hold button
Two-year warranty
Soft carrying case
Technical specifications
AC current Range Accuracy
40.00 A 2 % ± 5 digits (45 Hz to 65 Hz)
AC voltage Range Accuracy
DC Current Range Accuracy
DC voltage 400.0 A 2 % ± 5 digits
Resistance Range Accuracy
Continuity ≤ 30 Ω Capacitance 100.0 μF to 1000 μF Frequency 5.0 Hz to 500.0 Hz Backlight Yes Data hold Yes Contact temperature -10.0 °C to 400.0 °C (14.0 °F to 752.0 °F) Min/Max Yes Category rating CAT III 600 V, CAT IV 300 V
400.0 A
600.0 V 1.5 % ± 5 digits
40.00 A
400.0 A
600.0 V 1.0 % ± 5 digits
400.0 Ω 1.0 % ± 5 digits 4000 Ω
40.00 kΩ
2.5 % ± 5 digits (65 Hz to 400 Hz)
2 % ± 5 digits
Loading...