Four Things to Consider
Choose a clamp that
gives accurate and
repeatable results
Choose a clamp that
gives accurate and
repeatable results
Make sure the clamp
meter works where
you do
Make sure the clamp
meter works where
you do
Don’t compromise
on safety
Don’t compromise
on safety
When choosing
features, pick quality
over quantity
When choosing
features, pick quality
over quantity
When Buying a Clamp Meter
Does your clamp report the true-rms
reading?
Is the problem with your motor or
your clamp?
Make sure your clamp meter is
working for you, not against you.
Imagine that you have spent the whole day
troubleshooting a problem with a motor only
to discover that the problem wasn’t really
the motor, but the clamp you were using to
measure it. You stake your reputation on your
ability to get the job done, be sure your
clamp meter is working for you not
against you.
First, make sure your clamp
meter reports the true-rms
reading. Otherwise noise
from everything
including a variable
frequency drive to
compact fluorescent
bulbs can result in
a less accurate
reading.
Have you ever dropped your clamp?
Do you use your clamp outside?
Ever used you clamp to pry apart wires?
If so, make sure you clamp can work
where and how you do.
Making accurate and repeatable results in a
laboratory is a good start. But you don’t always
work in a clean and controlled environment.
Before making a purchase, check whether the
clamp is specified to work in the environment
you do.
Be sure you don’t buy a clamp specified for
indoor use only or with a minimum operating
range warmer than 15 °F if you think you
might need to make measurements outside. If
the clamp isn’t designed for the outdoors the
measurements you get might not be accurate.
Finally be sure the clamp you are using is rugged
enough to continue to give reliable results after
years of prying wires apart, drops from ladders
and bouncing around the back of your truck.
Does the clamp have the correct rating for
the work you are doing?
Can you use the meter easily when
wearing personal protective equipment?
If the answer is no, you could be
in danger.
Your test and measurement tools are a critical
barrier between you and danger. They are quite
literally an extension of your body into a very
dangerous environment. First things first, be sure
you choose a clamp meter with an appropriate
category rating for the work you are doing.
Second, choose a brand with a reputation for
providing safe and reliable test equipment.
Anyone can buy a clamp meter and put their
brand on it. Only a few manufacturers design,
build and test their own equipment to exceed
international safety standards.
Finally, your clamp meter is part of a safety
system that includes personal protective
equipment (PPE). In addition to having the right
PPE, be sure that you can easily operate your
test and measurement equipment with that
gear in place.
©2013Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 10/2013 4230855B_EN
Modification of this document is not permitted without written permission from Fluke Corporation.
Not using all the features on your
clamp meter?
If so, you could be wasting money
and functionality.
These days you can get almost
anything built into a
clamp meter (tape
measure anyone?). The
more gadgets that
are built into a clamp
meter, the harder it
becomes to use and
the worse it performs.
Instead of trying to
get the most features
possible, chose a meter
that has the measurement
functions you need to get
the job done, without
any of fluff that doesn’t
make sense. Plus, you
don’t end up paying for
features irrelevant to the
job at hand.

Fluke 320 Series
True-rms Clamp Meters
Fluke 320 Series
True-rms Clamp Meters
GO TO WORK
WITH THE
BEST.
GO TO WORK
WITH THE
BEST.
Big ac/dc features in a small
form factor.
General electrical measurements with
temperature and capacitance capabilities.
Fluke 323
The best option for general,
grab-and-go troubleshooting needs.
Fluke 324 Fluke 325
Measurement capability:
• 400 A ac current measurement
• 600 V ac and dc voltage
measurement
• True-rms ac voltage and current
for accurate measurements on
non-linear signals
• Resistance measurement up
to 4000 Ω with continuity
detection
Features:
• Slim, ergonomic design
• CAT IV 300V/CAT III 600 V
safety rating
• Hold button
• Two-year warranty
• Soft carrying case
Technical specifications
AC current Range Accuracy
400.0 A 2 % ± 5 digits (45 Hz to 65 Hz)
AC voltage Range Accuracy
DC voltage Range Accuracy
Resistance Range Accuracy
Continuity ≤ 70 Ω
Data hold Yes
Category rating CAT III 600 V, CAT IV 300 V
600.0 V 1.5 % ± 5 digits
600.0 V 1.0 % ± 5 digits
400.0 Ω 1.0 % ± 5 digits
4000 Ω
2.5 % ± 5 digits (65 Hz to 400 Hz)
Measurement capability:
• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current
for accurate measurements on
non-linear signals
• Resistance measurement up
to 4000 Ω with continuity
detection
• Temperature and capacitance
measurement
Features:
• Slim, ergonomic design
• Backlight display
• CAT IV 300V/CAT III 600 V
safety rating
• Hold button
• Two-year warranty
• Soft carrying case
Technical specifications
AC current Range Accuracy
40.00 A 1.5 % ±5 digits (45 Hz to 400 Hz)
400.0 A
AC voltage Range Accuracy
600.0 V 1.5 % ± 5 digits
DC voltage Range Accuracy
600.0 V 1.0 % ± 5 digits
Resistance Range Accuracy
400.0 Ω 1.0 % ± 5 digits
4000 Ω
Continuity ≤ 30 Ω
Capacitance 100.0 μF to 1000 μF
Backlight Yes
Data hold Yes
Contact temperature -10.0 °C to 400.0 °C (14.0 °F to 752.0 °F)
Category rating CAT III 600 V, CAT IV 300 V
Note: Add 2 % for position sensitivity.
Measurement capability:
• 400 A ac and dc current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current
for accurate measurements on
non-linear signals
• Resistance measurement up to
40 kΩ with continuity detection
• Temperature and capacitance
measurement
• Frequency measurement
• Min/Max functionality
Features:
• Slim, ergonomic design
• Backlight display
• CAT IV 300V/CAT III 600 V
safety rating
• Hold button
• Two-year warranty
• Soft carrying case
Technical specifications
AC current Range Accuracy
40.00 A 2 % ± 5 digits (45 Hz to 65 Hz)
AC voltage Range Accuracy
DC Current Range Accuracy
DC voltage 400.0 A 2 % ± 5 digits
Resistance Range Accuracy
Continuity ≤ 30 Ω
Capacitance 100.0 μF to 1000 μF
Frequency 5.0 Hz to 500.0 Hz
Backlight Yes
Data hold Yes
Contact temperature -10.0 °C to 400.0 °C (14.0 °F to 752.0 °F)
Min/Max Yes
Category rating CAT III 600 V, CAT IV 300 V
400.0 A
600.0 V 1.5 % ± 5 digits
40.00 A
400.0 A
600.0 V 1.0 % ± 5 digits
400.0 Ω 1.0 % ± 5 digits
4000 Ω
40.00 kΩ
2.5 % ± 5 digits (65 Hz to 400 Hz)
2 % ± 5 digits