Fluke 28 II Ex Specifications

Fluke 28II Ex
Intrinsically Safe True-rms
Digital Multimeter
Intrinsically Safe. Intrinsically Fluke.
The 28II Ex: the most rugged intrinsically safe digital multimeter in the world.
Now there’s one intrinsically safe digital multimeter you can use in Class 1, Div. 1 ­Zone 1 and 2 (gas) Class 2, Div. 1 or Class III - Zone 21 (dust) areas. Whether you work in petroleum, chemical, or pharmaceutical environments, all the test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built. The Fluke 28II Ex is also water-proof, dust-proof and drop-proof. You’ll be equipped to handle any situation, inside and outside of hazardous zones, without compromising compliance or measurement performance.
Technical Data
Intrinsically safe
The new 28II Ex certification allows you to carry the most trusted name in DMM’s into most Ex rated areas.
Intrinsically rugged
Intrinsically reliable
Like all Fluke DMMs, the 28II Ex delivers the accuracy and measurement performance you depend upon to succeed in your work, day after day.
The 28II Ex: the most rugged and reliable
intrinsically safe DMM in the world.
Intrinsic safety and regulatory approvals
The 28II Ex carries Ex certifications from the world’s leading certification bodies.
28II Ex I.S. Certifications
USA
Class I Zone 1 AEx ia IIC T4
Class II Zone 21 AEx iaD T130°C
USA and Canada
Class I, Division 1, Groups ABCD
Class I, Division 2, Groups ABCD
Class II, Division 1, Groups EFG
Class III
Australia, New Zealand, Brazil, Russia and European countries
See “Safety Specifications” on back page
28II safety and regulatory compliance
ISA-82.02.01
CAN/CSA-C22.2 No. 61010-1-04/
UL61010-1:2004, and TUV 61010-1:2001
CE
Classified to the following standards:
Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III, Division I, Hazardous (Classified) Locations (UL 913, Seventh Edition, Revised 2011/09/23)
Standard for Explosive Atmospheres - Part 0 - General Requirements (UL 60079-0, Fifth Edition, Issued 2009/10/21)
UL Standard for Safety Electrical Apparatus for Explosive Gas Atmospheres Part 11: Intrinsic Safety ‚i‘ (UL 60079-11, Third Edition, Revised 2011/05/05)
Electrical Apparatus for Use in Zone 20, Zone 21 and Zone 22 Hazardous (Classified) Locations - General Requirements (ISA 61241­0, Issued: 2006/07/13 (R2006))
Electrical Apparatus For Use In Zone 20, Zone 21 and Zone 22 Hazardous (Classified) Locations - Protection By Intrinsic Safety ‚id‘ (ISA 61241-11, Issued: 2007/01/29 (R2011))
Non-Incendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations (ISA
12.12.01, Issue:2011/01/01)
Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations; Consumer and Commercial Products; General Instruction No 1 (CSA C22.2 No. 157, Issue: 1992/01/01 (R2012))
Electrical Apparatus for Explosive Gas Atmospheres Part 0: General Requirements (CSA C22.2 No. 60079-0, Issued: 2007/03/01)
Electrical Apparatus for Explosive Gas Atmospheres Part 11: Intrinsic Safety “i” (CSA E60079-11, Issued: 2002/03/01 (R2011)
Enclosures for Use in Class II Groups E, F, and G Hazardous Locations General Instruction No 1 (CSA C22.2 No. 25, 1966/09/01 (R2004)
Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations; General Instruction No 1 (CSA C22.2 No. 213, Issue: 1987/03/01 (R2004)
Extreme ruggedness
The Fluke 28II Ex is the most rugged IS DMM you can buy.
A completely sealed, IP67 rated case
Withstands drops up to 3 meters or 10 feet
(with holster)
Waterproof per IEC60529 IP6x
Dustproof per IEC60529 IPx7
Meets IEC Overvoltage Electrical Safety
Standard No. 61010-1:2001
- Measurement Category III, 1000 V,
Pollution Degree 2
- Measurement Category IV, 600 V,
Pollution Degree 2
Reversible holster for added protection of the display when not in use