Fluke 2686A Technical Data

2680 Series
Data Acquisition Systems
The Fluke 2680A Data Acquisition System and Fluke 2686A Data Logging System (the 2680 Series) are the newest in a long line of Fluke precision data acquisition products. Both systems feature:
User-scalability from 20 to 120 universal analog input channels; can include digital input/output and alarm contact outputs in a single chassis.
Ethernet TCP/IP protocol with network interface for 10/100 BaseT.
Powerful HMI development software and OPC server software available.
Fluke 2680 Series: A powerful choice
The Fluke 2680 Series offers the choice of networked data acquisition, stand-alone data logging, or a combi­nation of both. Choose from two basic chassis models:
2680A Data Acquisition System chassis
The Fluke 2680A Data Acquisition System is the choice for multi-channel applications requiring reliable Ether­net communications. It features a front-end style data acquisition system that communicates and distributes data anywhere you need it to go. The 10BaseT and 100BaseT communications interface makes it compat­ible with both older and newer network installations.
2686A Data Logging System chassis
The Fluke 2686A Data Logging System writes data to a memory card for easy retrieval and storage, making it ideal for remote locations and mobile or non-computer assisted data logging applications. The system comes with a 16 MB ATA flash memory cards of up to 1 GB to provide the memory capacity stand-alone data logging operations by simply select­ing a preset configuration from the memory card. It can also be used in networks in tandem with the 2680A to provide the extra data security of a memory card.
you need. The 2686A is easily configured for
memory card, and supports ATA
Key system features:
20 to 120 universal analog inputs per chassis; systems to +2,000 channels
Stand-alone data logger operation with the 2686A
Large scalable LAN systems using the 2680A with
10BaseT/100BaseT
Two types of Universal Input Modules: high-isolation precision modules or fast scan modules, with 16- to 18-bit resolution
Throughput of more than 3,000 channels per-second per chassis with 2680A-FAI modules
Superior thermocouple measurement accuracy (J, K, R, S, T, N, L, U, C, B)
20 digital I/O and 8 form C, 1 Amp relay output modules for direct control of equipment
Up to 300 V input isolation, 1600 V transient overvoltage protection (2680A-PAI)
Universal input conditioning for any input, on any channel, in any combination (V dc, V ac, Ohms, frequency, RTD, thermocouple, thermistor or current)
ATA flash memory card for stand-alone operation—from 16 MB to 1 GB (2686A only)
Multiple power sources: 100 V to 240 V and 9 V to 45 V dc
Includes Fluke DAQ Software which:
– Controls all 2680 Series functions and data files – Provides real-time and historical trending – Also communicates with and controls Fluke 2640A, 2645A
NetDAQ products
Technical Data
Scale your system to meet your needs
With the Fluke 2680A and the 2686A, you can seam­lessly expand your system from 20 to more than 2,000 channels just by adding modules and chassis. Both models feature six slots in each chassis that you can fill with modules as needed to meet your application requirements. Five slots in each chassis are available for any combination of 20-channel analog input mod­ules available for the 2680 Series. The sixth slot is also available for a digital I/O relay module to add control capabilities to your system. If you don’t need the sixth slot for control, you can plug in an additional analog input module, increasing your input 120 in one chassis.
You can also link multiple 120-channel systems together seamlessly for the widest possible view of your data. And, with TCP/IP connectivity, you can connect to existing LANs to distribute information wherever it needs to go.
Whether you need speed and throughput, isolated precision, or digital I/O and relays, the Fluke 2680 Series can scale up to thousands of channels to meet your needs. Buy just the modules you need in the com­binations you need and expand your system as your requirements grow.
2680A-FAI: The speed to capture dynamic process changes
The Fluke 2680A-FAI (Fast Analog Input) is a perfect choice when you need a lot of information in a hurry and still need to maintain a high degree of accu­racy for your measurements. The 2680A-FAI module provides chassis throughput rates of more than 3,000 channels-per-second. Specially manufactured field effect transistors (FETs) allow up to ± 50 V input, and channel-to-channel isolation well above the 15 V industry norm, to give you more confidence in the integrity of your measurements.
2680A-PAI provides high precision and high isolation for the most demanding jobs
The Fluke 2680A-PAI (Precision Analog Input) 20-channel high-precision, high-isolation module serves the most demanding jobs where precision is paramount and isolation is critical. Some of the most notable applications for this module include temperature measurement in semiconductor and pharmaceutical manufacturing, as well as nuclear plant performance monitoring. The 2680A-PAI module offers 300 V of isolation on two channels and 150 V on 18 channels, as well as 18-bit resolution and excellent thermocouple accuracy, all in a scalable system.
Both the 2680A-FAI and the 2680-PAI modules support a wide range of inputs including dc volts, ac volts, RTD, Ohms, thermocouple, thermistor, dc cur­rent, ac current, and frequency. Other sensors and transducers, such as load cells, pressure sensors, and displacement sensors can be easily incorporated into your measurement system.
channel count to
2686A Active Channels and Memory Card Capacity (Scans)
Memory Card/ Active Channels 20 ch 40 ch 60 ch 80 ch 100 ch 120 ch
16 MB 100,548 66,765 50,074 40,059 33,382 28,613
128 MB 800,000 528,000 400,000 320,000 264,000 224,000
256 MB 1.6 M 1.056 M 800,000 640,000 528,000 448,000
512 MB 3.2 M 2.112 M 1.6 M 1.28 M 1.056 M 896,000
1 GB 6.2 M 4.224 M 3.2 M 2.56 M 2.112 M 1.792 M
2680A-DIO: Digital I/O and relay outputs add control
For data acquisition systems that also require control functionality, the Fluke 2680A-DIO digital I/O and relay output module provides 20 digital I/O and eight hard-contact 1 Amp form-C relays. This equips each chassis to respond to a wide range of alarm or control situations. The 2680A-DIO also includes an up/down counter with preset start count capability, so you don’t need to begin all counts at zero.
2680A-180: Universal Input Module requires no external signal conditioning
Fluke’s patented Universal Input Module is included with all Fluke data acquisition products, providing unparalleled thermocouple accuracy and compatibility with a broad range of diverse inputs. The Universal Input Module enables you to easily measure just about any electrical or physical parameter without changing hardware or adding external signal conditioning. You can connect any combination of dc voltage, ac voltage, thermocouples, current, RTD, resistance (2- or 4-wire), or frequency measurement inputs directly to the input module.
2 Fluke Corporation Fluke 2680 Series Data Acquisition Systems
2680 Series DIO Module and Universal Input Module
Fluke DAQ Software makes it easy to get the most out of your data
Each Fluke 2680A and 2686A comes with our pow­erful, highly- flexible, yet easy-to-use Fluke DAQ Configuration Software. Fluke DAQ allows you to con­figure the 2680 Series for:
Input type
Alarms
Math functions
Totalizer function
Digital I/O lines
Scan speed
Interval
Trigger type
You can use Fluke DAQ Software to set up data files, collect and chart data in real-time or historical mode, and manage memory card files. Using Fluke DAQ, you can collect data from your system the way you need to and distribute it where you want it. And you can share data with others, anywhere on your LAN or anywhere around the world using Web servers.
Fluke DAQ Software also enables you to integrate Fluke NetDAQ 2645A) into your 2680 Series system, providing almost unlimited channels working together seamlessly.
®
data acquisition products (2640A and
Fluke 2680A-OPC: Create custom applications using OLE for Process Control
Optional Fluke 2680A-OPC software gives you the freedom to integrate your 2680 Series into any OPC­compliant application. Create custom applications using 2680A-OPC software and just about any popular industrial software package such as Wonderware, LabVIEW,
Test Point, or Indusoft Web Studio, as well
®
as software from Canary Labs, Daisy Labs, and others. Open, non-proprietary OPC support enables you to use the software you choose or the software you create.
Fluke 2680A-DLL library: For developing or modifying applications
The 2680A DLL library is designed for programmers who want to develop or modify their own applications for the 2680 Series, using C++, Visual Basic, and other languages.
Fluke DAQ Software: Configuration made simple
Optional software extends system capabilities
Fluke has partnered with industrial software developer Indusoft to create additional tools to extend the power of your 2680 Series system. Optional software tools allow you to create human machine interfaces and develop custom applications that interact with other equipment and software packages.
Fluke 2680A-DEVSW: Development software for HMI design
The optional 2680A-DEVSW tool is based on Indusoft Web Studio, an object oriented development software program that works with Fluke DAQ Software. This unique development system allows programmers and non-programmers to develop modern human machine interfaces (HMI) which open graphical windows to your application.
Key features of this powerful development package include:
An extensive graphics library
Drag & drop programming
More than 140 device drivers
OPC client/server compliance
Support for DNA, OPC, DDE, OBDC, XML, SOAP and
Active X
Automatic language translation at run-time
Internationalization using Unicode
Web display and alarm paging
Support for imported graphics formats
The ability to view multiple clients from one web
browser
Fluke DAQ Software: Real time and historical trending
2680A-DEVSW: Powerful HMI development software
3 Fluke Corporation Fluke 2680 Series Data Acquisition Systems