Fluke 183, 185 User Manual

Page 1
183 & 185
True RMS Multimeters
®
Users Manual
February 2001 Rev.2, 4/02
© 2001-2002 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies.
Page 2
Each Fluke 20, 70, 80, 170 and 180 Series DMM will be free from defects in
material and workmanship for its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least ten years from the date of purchase. This war­ranty does not cover fuses, disposable batteries, damage from neglect, misuse, contamination, alteration, accident or abnormal conditions of operation or han­dling, including failures caused by use outside of the product’s specifications, or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable.
For ten years from the date of purchase, this warranty also covers the LCD. Thereafter, for the lifetime of the DMM, Fluke will replace the LCD for a fee based on then current component acquisition costs.
To establish original ownership and prove date of purchase, please complete and return the registration card accompanying the product, or register your product on http://www.fluke.com. Fluke will, at its option, repair at no charge, replace or refund the purchase price of a defective product purchased through a Fluke authorized sales outlet and at the applicable international price. Fluke reserves the right to charge for importation costs of repair/replacement parts if the product purchased in one country is sent for repair elsewhere.
If the product is defective, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Fluke will pay return transportation for product repaired or replaced in-warranty. Before making any non-warranty repair, Fluke will estimate cost and obtain authorization, then in­voice you for repair and return transportation.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WAR­RANTY ON FLUKE’S BEHALF. Since some states do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. If any provision of this warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven U.S.A. The Netherlands
2/02
Page 3
Table of Contents
Title Page
Introduction.......................................................................................... 1
Contacting Fluke.................................................................................. 1
Safety Information................................................................................ 2
Safety Terms..................................................................................... 2
Symbols ............................................................................................ 2
Safety Precautions............................................................................ 3
Front and Rear Panel Overview............................................................ 6
Measurement Function Knob ........................................................... 9
Input Connectors.............................................................................. 10
Operating Basics................................................................................... 11
Safe Test Lead Connections............................................................. 11
Using Procedures in this Section...................................................... 12
Voltage Measurements..................................................................... 13
Application: Using AC DC and AC+DC in Volts Mode.............. 14
dB and dBm Voltage Measurements................................................ 15
Application: Using a Reference Value Other than Default
1.000 V RMS in dB Mode............................................................ 15
Application: Using Voltage in a Circuit as the Reference
Value in dB Mode ........................................................................ 15
Frequency Measurements................................................................. 16
Negative Edge Triggering............................................................. 16
Positive and Negative Duty Factor............................................... 16
AC vs. DC Coupled Frequency Measurements ............................ 17
Changing Voltage Range in Frequency Mode.............................. 17
Resistance Measurements (Ohms, Continuit y, Dio de,
and 50 Ω Range)............................................................................... 18
Application: Measuring Low Resistance Values.......................... 19
Capacitance Measurement................................................................ 19
Temperature Measurements (185 only)............................................ 20
Helpful Tip: Increased Temperature Accuracy............................. 20
Current Measurements...................................................................... 21
Button and Softkey Overview .............................................................. 22
Yellow (Shift) Button....................................................................... 22
RANGE Button ................................................................................ 22
MIN MAX (Minimum, Maximum) Button...................................... 23
i
Page 4
183 & 185
Users Manual
FAST MIN MAX (1 ms Peak)......................................................... 23
Backlight Button (s)...................................................................... 23
HOLD Button................................................................................... 23
Auto Hold ........................................................................................ 24
REL t Button (Making Relative (REL t) Measurements)........... 24
MEMORY ....................................................................................... 25
Softkeys (1 2 3 4)................................................. 26
Setup Menu...................................................................................... 26
Special Features................................................................................... 27
High Resolution (HrES) 50,000-Count Mode.................................. 27
Beeper.............................................................................................. 28
Auto-Off........................................................................................... 28
Power-Up Options............................................................................ 28
MIN MAX AVG Operation............................................................. 31
Auto Fuse Detection......................................................................... 32
Specifications....................................................................................... 33
Accessories .......................................................................................... 46
Setup for Optional Computer Interface Accessory (FlukeView Forms) 47
Using Protective Holster and Tilt-Stand .............................................. 48
Battery Replacement............................................................................ 48
Servicing the Meters............................................................................ 49
Replacing the Fuse........................................................................... 50
General Care and Cleaning .................................................................. 51
t Relative to a Measured Value ................................................. 24
t Relative to a Saved Value ....................................................... 24
t Relative to a Programmed Value............................................. 25
STO.............................................................................................. 25
RCL.............................................................................................. 25
CLR.............................................................................................. 26
EXIT ............................................................................................ 26
ii
Page 5
List of Tables
Table Title Page
1. Symbols............................................................................................. 2
2. Setup Prompts, Definitions, and Default Values................................ 27
3. Power-up Options.............................................................................. 29
4. MIN MAX Operations....................................................................... 31
5. DC Voltage Characteristics................................................................ 34
6. DC Voltage Range, Resolution, and Accuracy.................................. 34
7. AC Voltage Characteristics................................................................ 35
8. AC Voltage Range, Resolution, and Accuracy.................................. 36
9. DC Current Characteristics................................................................ 36
10. DC Current Range, Resolution, and Accuracy................................... 37
11. AC Current Characteristics................................................................ 37
12. AC Current Range, Resolution, and Accuracy................................... 38
13. Resistance (Ω) Characteristics........................................................... 38
14. Resistance Range, Resolution, and Accuracy.................................... 39
15. Continuity Characteristics.................................................................. 39
16. Diode Test Characteristics................................................................. 40
17. Capacitance Range, Resolution, and Accuracy (5,000 counts only).. 40
18. Frequency Characteristics, Resolution, and Accuracy....................... 41
19. Frequency Voltage Range.................................................................. 41
20. Duty Factor Characteristics................................................................ 41
21. Temperature Characteristics .............................................................. 42
22. FAST MIN MAX (1 ms) Characteristics........................................... 42
23. Physical Characteristics..................................................................... 42
24. Environmental Characteristics........................................................... 43
25. Certifications and Compliances......................................................... 44
26. Standard Accessories......................................................................... 46
iii
Page 6
183 & 185
Users Manual
iv
Page 7
List of Figures
Figure Title Page
1. Front Panel (185 is shown)................................................................ 6
2. Rear Panel View (185 is shown) ........................................................ 7
3. Display Indicators.............................................................................. 8
4. Measurement Function Knob............................................................. 9
5. Input Connectors................................................................................ 10
6. Meter Softkeys................................................................................... 12
7. Positive and Negative Duty Factor .................................................... 17
8. Setup for the Optional Computer Interface Accessory....................... 47
9. Holster and Tilt Stand........................................................................ 48
10. Replacing the Batteries...................................................................... 49
11. Opening the Case............................................................................... 50
12. Fuse Access ....................................................................................... 51
v
Page 8
183 & 185
Users Manual
vi
Page 9
Fluke 183 &185
True RMS Digital Multimeters
Introduction
The Fluke 183 and 185 True RMS Digital Multimeters (hereafter referred to as "the meter") are handheld, battery-o perated instruments that measure and source electrical and physical parameters. These Meters comply with IEC 1010
nd
2
edition for CAT III 1000 V and CAT IV 600 V environments.
WWarning
To avoid injury and ensure safe operation of the meter, follow all safety precautions detailed in this manual.
Contacting Fluke
To order accessories, receive operating assistance, or get the location of the nearest Fluke distributor or Service Center, call:
USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500
Or, visit Fluke’s Web site at
www.fluke.com.
1
Page 10
183 & 185
Users Manual
Safety Information
Review the following safety precautions to avoid injury and prevent damage to the meter or any products connected to it. To avoid potential hazards, use the meter only as specified
Safety Terms
The following terms appear in this manual:
WWarning- Warning statements identi fy co nditions or practices that co uld
result in injury or loss o f life.
Caution-
in damage to the meter or other property
Caution statements identify conditions or practices that could result
.
Symbols
Refer to Table 1 for a listing of symbols that may appear on the meter or in this manual.
Table 1. Symbols
Y
W
T
M
P
Risk of electric shock See manual Equipment protected by double or reinforced Insulation Battery Conforms to CSA C22.2 No 1010. 2.032-96
Conforms to EU directives
J
D
;
N10140
VDE Conforms to VDE EN61010
2
Earth AC or DC Conforms to relevant Australian standards
Inspected and licensed by TÜV Product Services
Page 11
True RMS Digital Multimeters
Safety Precautions
WWarning
Only qualified personnel should perform service procedures.
To avoid fire or personal injury:
Connect and disconnect properly. Do not connect or
disconnect probes or test leads while they are connected to a voltage source.
Observe all ratings and markings on the meter. Consult
the meter manual for further ratings information before making connections to the meter.
Do not apply a potential to any terminal, including the
common terminal, that exceeds the maximum rating of that terminal.
Safety Information
If this product is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be impaired.
Replace batteries only with the proper type and rating
specified. Do not operate the meter with covers or panels
removed. Use only the fuse type and rating specified for this
meter. Avoid exposed circuitry. Do not touch exposed
connections and components when power is present. If you suspect there is damage to the meter, have it
inspected by qualified service personnel. Do not operate in wet/damp conditions. Do not operate
in an explosive atmosphere. Keep meter surfaces clean and dry.
This meter is sensitive to strong external magnetic
fields. Do not use the meter within 1-inch (2.54 cm) of strong
external magnetic fields such as that produced by the Fluke ToolPak hanging magnet accessory. Incorrect readings may result. If erratic behavior is noted, turn meter off to reset.
3
Page 12
183 & 185
Users Manual
WWarning
To avoid possible electric shock or personal injury, follow these guidelines:
Before and after measuring hazardous voltages (≥ 30 V
ac rms, 42 V peak, or 60 V dc), verify the meter’s proper operation by measuring a known voltage.
Do not use the meter if it is damaged. Before you use
the meter, inspect the case. Look for cracks or missing plastic. Pay particular attention to the insulation surrounding the connectors.
Inspect the test leads for damaged insulation or
exposed metal. Check the test leads for continuity. Replace damaged test leads before you use the meter.
If this product is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be impaired.
Do not use the meter if it operates abnormally.
Protection may be impaired. When in doubt, have the meter serviced.
Do not operate the meter around explosive gas, vapor,
or dust. Do not apply more than the rated voltage, as marked
on the meter, between terminals or between any terminal and earth ground.
Before use, verify the meter’s operation by measuring
a known voltage. When measuring current, turn off circuit power before
connecting the meter in the circuit. Remember to place the meter in series with the circuit.
When servicing the meter, use only specified
replacement parts. Use caution when working above 30 V ac rms, 42 V
peak, or 60 V dc. Such voltages pose a shock hazard.
Avoid working alone.
When using the probes, keep your fingers behind the
finger guards on the probes.
4
Page 13
True RMS Digital Multimeters
Safety Information
Connect the common test lead before you connect the
live test lead. When you disconnect test leads, disconnect the live test lead first.
Remove test leads from the meter before you open the
battery door. Do not operate the meter with the battery door or
portions of the cover removed or loosened. To avoid false readings, which could lead to possible
electric shock or personal injury, replace the batteries as soon as the low battery indicator (M) appears.
Use only type AA batteries, properly installed in the
meter case, to power the meter. To avoid the potential for fire or electrical shock, do
not connect the thermocouples to electrically live circuits.
Caution
To avoid possible damage to the meter or to the equipment under test, follow these guidelines:
Disconnect circuit power and discharge all high-
voltage capacitors before testing resistance, continuity, diodes, or capacitance.
Use the proper terminals, function, and range for your
measurements. Before measuring current, check the meter’s fuses and
turn power OFF to the circuit before connecting the meter to the circuit.
5
Page 14
183 & 185
Users Manual
Front and Rear Panel Overview
TRUE RMS MULTIMETER
185
1
2
F
2
F
3
F
CAT 1000V
4
6 7
HOLD
A
REL
8 9
MEMORYFAST MIN MAX
10
Hz
F
1
3 4 5
RANGE
MIN MAX
Hz
V
OFF
COM VA
10A MAX
FUSED
A Extra large LCD display with dual numerical readout. B Measurement function knob – Use to select a measurement.
C
Yellow (shift) button– Use to access FAST MIN MAX, MEM, and Setup menu.
D RANGE button – Use to set measurement range.
ahr01f.eps
E MIN MAX button – Use to set meter to MIN MAX or Fast (1ms) modes.
F 1234
select measurements.
G s
– Use to turn backlight on and off.
H HOLD button – Use to freeze display or select Auto Hold. I REL t button – Use to make relative measurements and access the
memory.
J Input connectors.
Figure 1. Front Panel (185 is shown)
6
Softkeys – Use with measurement function knob to
Page 15
True RMS Digital Multimeters
Front and Rear Panel Overview
1
2
3
4
5
ahr02f.eps
A
Press and hold options – Activate by holding down the specified button for two seconds while the meter is on.
B Power-up options – Activate by holding down the specified button while
turning on the meter.
C Compliance and battery and fuse replacement information. D Serial number and barcode tag. E Removable battery cover.
Figure 2. Rear Panel View (185 is shown)
7
Page 16
183 & 185
Users Manual
6
1 2
3 4
5
A Special feature indicators B Low battery indicator C RELt indicator
7
8
9
10
11
ahr03f.eps
D Yellow (shift) button and memory mode indicators E Bargraph F Upper display G Upper display units H Main display I Main display units J Range indicators K Softkey menus
Figure 3. Display Indicators
8
Page 17
Measurement Function Knob
True RMS Digital Multimeters
Front and Rear Panel Overview
Hz
V
OFF
A
Hz
V
OFF
A
183 185
ahr04f.eps
OFF -Turns off the meter. Setup parameters and stored measurements are saved.
V- Volts AC RMS, Volts DC, Volts AC DC dual display, Volts AC+DC total
RMS, dB, and dBm.
Hz - Frequency measurements. Duty factor also shows if it is turned on in the
Setup menu.
Re/G -Access to resistance and continuity measurements and diode
test.
E- Capacitance measurements.
T - Temperature measurements in degrees Celsius or Fahrenheit.
A - Amps AC RMS, Amps DC, Amps AC + DC total RMS, Amps AC DC dual display, and Amps DC 4-20 mA% (process control loop measurement).
Figure 4. Measurement Function Knob
9
Page 18
183 & 185
Users Manual
Input Connectors
COM VA
Hz
10A MAX
FUSED
CAT 1000V
ahr05f.eps
A - Input connector for current measurements up to 10 A (15 A for 30
seconds).
COM - Common connector. All measurements are referenced to this
connector.
V - Input connector for volts, frequency, ohms, continuity, diode, capacitance,
and temperature measurements.
Figure 5. Input Connectors
To avoid personal injury, do not attach meter leads the battery cover removed.
To avoid damaging the meter, do not attempt to measure current with the batteries removed.
10
WWarning
Caution
with
Page 19
True RMS Digital Multimeters
Operating Basics
Operating Basics
Before you take any of the measurement s d e scribed in this section, follow these steps:
For specified accuracy, allow the meter to stabilize for 30 seconds after
you turn on the meter.
Observe the safe test lead connections below when you remove the test
leads from the meter.
Always disconnect power to the circuit when you measure resistors,
capacitors, diodes, or continuity within the circuit.
Discharge capacitors before taking capacitance measurements.
Safe Test Lead Connections
To safely disconnect the test leads from the meter, first disconnect all test leads from the circuit being tested, then disconnect the leads from the input connectors.
WWarning
To prevent electrical shock, do not insert unnecessary test leads or metal pins into the A (amps) connector. Voltages applied to any connector may be present at all other input connectors. Only use the test leads supplied or recommended (or their equivalent) with the meter. Refer to the "Accessories" section.
11
Page 20
183 & 185
Users Manual
Using Procedures in this Section
All measurements are made by first setting the measurement function knob to a function setting and then selecting a measurement from the softkeys. Note that not all knob settings have corresponding softkey setting s.
For example, the steps below explain how to make a DC voltage measurement:
1. Set the measurement functio n knob to V for a voltage measurement.
2. Select softkey
2
for DC voltage.
3. Connect the leads to the measurement points.
F
F
1
2
Figure 6. Meter Softkeys
F
3
F
4
ahr07f.eps
12
Page 21
Voltage Measurements
True RMS Digital Multimeters
Operating Basics
Measurement Softkey Connect Leads
True RMS
1 AC AC Hz AC voltage (default)
DC voltage 2 DC
AC DC dual display
3
AC DC
or
AC+DC total
1
RMS
AC+DC
(press to
toggle)
ahr08f.eps
ahr08f.eps
Main
Display
Display
DC ––
DC AC
AC+DC Hz
Upper
1
VRMS =
VDCVAC +
22
13
Page 22
183 & 185
Users Manual
Application: Using AC DC and AC+DC in Volts Mode
DC = 5 V AC = 1V RMS Frequency = 60 Hz
ahr09f.eps
AC voltages riding on power supplies can cause problems with electronic circuits. If you set the meter to DC Volts mode, the display shows the DC component of 5.000 V. However, the AC component may be missed. It is recommended that you set the meter to AC DC dual display mode. The main display shows the 5.000 V DC voltage and the upper display shows the 1.000 V AC voltage. AC DC mod e also allo ws you to simu ltaneously make AC and DC measurements without changing the meter settings.
Another useful measurement is AC+DC total RMS. To take this measurement, press softkey
3
to toggle to AC+DC. In the above exa mple, the total RMS of 5.099 V shows on the main display and the frequency of 60.00 Hz shows on the upper display. When calculating the power dissipated in a circuit component, it is critical that the DC value is factored into the equation VRMS X IRMS, where VRMS is AC+DC total RMS.
14
Page 23
True RMS Digital Multimeters
dB and dBm Voltage Measurements
Operating Basics
Main
Measurement Softkey Connect Leads
dB (185 only) dBm (185
2
only)
1
dB readout = 20 X log (main display readout/ref), where ref = 1 V is the
default.
2
dBm readout = 10 X log (main display readout2/R), where R=600
1
4
or dBm (press to toggle)
dB
ahr08f.eps
Display
AC dB AC dBm
e
.
Upper
Display
Application: Using a Reference Value Other than Default
1.000 V RMS in dB Mode
To manually change the reference voltage in dB mode, press and hold the yellow (shift) button to display the Setup menu. Adjust the the value you want and press softkey
4
for OK. Subseq uent dB
rEF (dB)
measurements will use this stor ed value as the reference voltage until you turn off the meter.
value to
Application: Using Voltage in a Circuit as the Referen ce Value in dB Mode
An example of using a voltage in a circuit as the reference value is measuring the AC voltage gain of an amplifier. Set the meter to dB mode and measure the voltage that you want to use for the r eference (the input of the amplifier). Pr ess
t
REL
output of the amplifier. The voltage gain of the amplifier (in dB) shows in the upper display.
In both of these applications, the t indicator shows in the upper display to indicate the reference is a voltage other than the default value of 1.000 VRMS. The reference value returns to 1.000 V when you exit dB mode.
to save the measured value as the reference value. Next, measure the
15
Page 24
183 & 185
Users Manual
Frequency Measurements
Main
Measurement Softkey Connect Leads
Frequency Hz – EdGE
(no
Display
Upper
Display
selection)
Frequency
Hz % Duty and duty factor dual display
ahr08f.eps
1
Displayed when you set negative edge triggeri ng in th e Setup menu. –
but not displayed when % duty is on.
2
You must turn on positive or negative duty in Setup menu.
EdGE
is active
Negative Edge Triggering
To trigger on the negative edge of the waveform, set Setup menu. The word
-EdGE
shows in the upp e r display when you exit the
Setup menu.
EdGE
to
nEG
in the
1
2
Positive and Negative Duty Factor
To measure duty factor, set duty (
nEG
. When you measure negative duty factor, a “–” symbol shows in the
upper display.
POL
in the Setup menu) to either
POS
or
16
Page 25
True RMS Digital Multimeters
Operating Basics
b
a
Figure 7. Positive and Negative Duty Factor
ahr10f.eps
Positive duty factor: % duty = (a/b) x 100
Negative duty factor: % duty = (1–a/b) x 100
AC vs. DC Coupled Frequency Measurements
When the duty factor measurement mode is off, the frequency measurement is AC coupled; otherwise, it is DC co upled.
Changing Voltage Range in Frequency Mode
To change voltage range , press RANGE. The voltage range shows momen tarily in the upper display. Continue pressi ng voltage ranges until t he range you want shows. The default voltage range is 5 V.
RANGE to cycle through the available
17
Page 26
183 & 185
Users Manual
Resistance Measurements (Ohms, Continuity, Diode, and 50 Ω Range)
Measurement Softkey Connect Leads
Resistance
1
(default)
ahr11f.eps
Continuity 2 R
ahr12f.eps
Diode 3 G
Main
Display
Upper
Display
--
OPEn
or
Shrt
(beeps on
short)
V--
1
50
1
See application below.
4 50
Forward bias Reverse bias
ahr13f.eps
--
ahr14f.eps
18
Page 27
True RMS Digital Multimeters
Operating Basics
Application: Measuring Low Resistance Values
To measure low resistance values to 0.01 Ω resolution, set the meter to 50 Ω mode and short the leads together to subtract the lead resistance from low­resistance measurements. If you do not short the leads together, the meter will not enter 50 Ω mode. The lead resistance must be less than 5 Ω. The measured resistance shows on t he main display.
Caution
To avoid damaging the meter, remove all power from the circuit before connecting the test leads.
Capacitance Measurement
Measurement Softkey
Capacitance (no
selection)
Connect
Leads
ahr15f.eps
Main
Display
F--
Upper
Display
Caution
To avoid damaging the meter, remove all power from the circuit before connecting the test leads.
Measuring large-value capacitors may take seve ral seconds. Follow the procedures below when making capacitance measurements:
Remove capacitors from circuitry.
Discharge capacitors before measuring them.
To measure small values of capacitance accurately, press
the leads are open.
REL t
when
19
Page 28
183 & 185
Users Manual
Temperature Measurements (185 only)
Measurement Softkey
Celsius temperature (default)
Fahrenheit temperature
1 °C °C Ambient
2 °F
Connect
Leads
Thermocouple
probe adapter
K-Type
Temperature probe
ahr16f.eps
Main
Display
°F Ambient
Upper
Display
temp. °C
temp. °F
Before you take a temp erature measurement, momentarily change the temperature of the thermocouple to verify a shorted or open thermocouple is not incorrectly displaying the ambient temperature.
Helpful Tip: Increased Temperature Accuracy
To achieve high accuracy temperature measurements to ±1.0 °C it is necessary to calibrate the meter to account for any thermocouple offset. Temperature accuracy without performing the following calibration is ±3 °C:
1. Turn on the meter in the environme nt you will make the measurements.
2. Fill a wide, shallow container with ice and water. Stir the ice and water
mixture for two or three minutes to evenly distribute the temperature of the mixture. Place the container next to the meter and submerge the tip of the bead probe in the ice and water.
3. While in °C or °F mode, allow the temperature reading to stabilize on a value (this va lue should b e very close to 0 °C for °C mode or 32.0 °F for °F mode). Any deviation from 0 °C or 32 °F represents the
thermocouple’s offset.
4. Once the reading stabilizes, press and hold softkey softkey
2
for °F mode for five seconds until the display shows 0000 or
1
for °C mode or
0032.
20
Page 29
True RMS Digital Multimeters
Operating Basics
This calibrates the meter for the operating environment. t shows in the upper display. If you hear an error beep, the offset is greater than ±5 °C. You can repeat this calibration at any time. To undo this calibration, return the meter to factory settings by pressing both the yellow (shift) button and
MIN MAX while
powering up the meter (see Table 3. Power-up Options). To insure accuracy of temperature measurements, you should follow this
procedure when using other K-type thermocouple probes with the 183/185 DMMs because accuracy specifications vary in different types of probes.
Note
Observe proper polarity on the probe adapter and do not calibrate the offset immediately following high amperage measurements.
Current Measurements
Measurement Softkey Connect leads
True RMS AC
1 AC AC Hz
Main
Display
Upper
Display
Amps DC Amps
2 DC DC --
(default) Amps AC DC
dual display Amps AC+DC
total RMS
1
4-20 mA current %
2
3 AC DC or AC+DC (press to toggle)
4
20 mA
LoadCurrent
source
ahr17f.eps
DC AC
AC+DC Hz
DC %
(185 only)
1
2
4-20 mA measurement is used in process loop calibration. % = (measured
22
IDCIACIrms +=
current – 4 mA)/16 mA
21
Page 30
183 & 185
Users Manual
When overrange occurs in manual range, the meter will uprange in order to protect the internal circuitry.
Caution
To avoid damaging the meter, limit large current measurements to 15 A for 30 seconds and allow ten minutes of cooling between measurements.
Do not attempt to measure current with batteries removed.
When you exit current measurement mode, the words the display reminding you to remove your test lead from the A (amps) input connector.
When you make high cur rent measurements, >15 A, use a current clamp probe (optional accessory).
CHEC ProbE
show on
Button and Softkey Overview
Yellow (Shift) Button
To access functions in yellow text, press the yellow (shift) button and then press a function button while the shows on the disp lay for five seconds.
Press and hold the yellow(shift) button for two seconds to access the Setup menu. See "Setup Menu" for more information.
S
indicator is on. The
S
indicator
RANGE Button
Use the RANGE button to manually select a range. Press and hold RANGE for two seconds to return the meter to auto range mode. The meter is in auto range mode when the
The range and units are displayed above the bargraph.
AUTO indicator is on.
AUTO indicator, to the right of the
22
Page 31
True RMS Digital Multimeters
Button and Softkey Overview
MIN MAX (Minimum, Maximum) Button
Press this button to scroll through the live, maximum, mini mum,
maximum–minimum, and average value. The elapsed time between the last recorded event and the start of the test shows in the upper display.
Press and hold See "MIN MAX AVG Operation" for more information.
MIN MAX for two seconds to exit MIN MAX mode.
FAST MIN MAX (1 ms Peak)
To activate 1 ms peak, first press the yellow (shift) button and then MIN MAX while the fast mode, the LCD displays the resolution in fast MIN MAX is 5,000 counts. Live and average (AVG) readings are not available in fast MIN MAX mode.
You can use FAST M IN MAX whe n you take AC or DC measurements. The meter only records events that have a pulse width that is greater than 1 ms.
Press value shown is the value of the positive peaks and the MIN value shown is the value of the negative pe aks.
Press and hold
S
MIN MAX to view 1ms peak minimum and maximum values . The MAX
indicator shows on the display. When in
FAST
MIN MAX for two seconds to exit FAST MIN MAX mode.
and
M
indicators. Display
Backlight Button (s)
Press s to turn the backlight on or off. Adjust the LOFF setting in the Setup menu to adjust the backlight timeout setting. To adjust the setting for the backlight , refer to the "Setup Menu" section.
HOLD Button
Press HOLD to turn hold mode on and off. When you activate the hold feature, the instrument beeps, freezes the display, and displays the Hold mode freezes the display so you can remove the probes from the test points without losin g the measurement reading.
HOLD indicator.
23
Page 32
183 & 185
Users Manual
Auto Hold
To activate auto hold, press down on HOLD until A HOLD appears on the display. Auto hold is not available for capacitance or AC DC measurements.
In auto hold mode the display automatically freezes and the instrument beeps when the measurement reading stabilizes. The displayed value will be updated when the meter stabilizes on a new measurement value.
Auto hold is useful when it is not possible for you to press meter display while probing and taking measurements.
REL
Use this button to set the meter to d elta mode and make relative measurements. The reference value for the t measurement can be a measured, a stored, or a programmed value.
t
When you take the measurement and the meter settles on the measurement value, press subtracted from the actual measurement.
t
Use the measurement function knob and softkeys to set the meter to the measurement function you want. Use the memory information in the "MEM (Memory)" section to recall (RCL) a reference value from memory, then press
REL
t Button (Making Relative (
Relative to a Measured Value
REL t
. For subsequent readouts, the measured reference value is
Relative to a Saved Value
t
. To exit delta mode, press REL t.
REL
t) Measurements)
HOLD or see the
For subsequent readouts, the recalled reference value is subtracted from the actual measurement.
24
Page 33
True RMS Digital Multimeters
Button and Softkey Overview
t
Relative to a Programmed Value
Use the measurement function knob and softkeys to set the meter to the measurement function and range you want and then press meter is in delta mode, press and ho ld the yellow (shift) button until the Setup menu appears. Use the softkeys to edit rEF to the desired value and press softkey
For subsequent readouts the programmed reference value is subtracted from the actual measurement. The programmed reference value is lost when you turn off the meter.
4
for OK. To exit delta mode, press
REL
t
.
REL
t
. While the
You can also use and dBm Voltage Measurements" for more information.
REL
t
to make relative dB (t
dB) measurements. See "dB
MEMORY
Use the memory mode to store and recall measurement values. No data is lost during power cycles.
To activate the MEMORY mode, press the
t
while
selections:
SHIFT shows on the LCD display. The display shows four softkey
STO, RCL, CLR, and EXIT.
yellow (shift) button and then REL
STO
Select STO to store the held value in the next available memory location. The memory location number momentarily shows on the upper display. If no memory locations are available, seconds and nothing is stored.
To overwrite an existing memory value, recall the memory location using the
RCL button, press CLR, then press STO to store the new value in this location.
FULL shows on the upper display for two
RCL
Select RCL to scroll through the stored values in reverse order. The upper display momentarily shows the memory location while the main display shows the value stored in that location.
25
Page 34
183 & 185
Users Manual
CLR
Select CLR to clear the currently selected memory location. The location is
replaced with “
-----”.
To clear all memory locations, press and hold shows on the display next to the CLR enunciator. The word
CLR for five seconds. A ?
donE
shows on the display indicating that all memory locations are clear and you can release the button. If you release the button before the word
donE
shows, no data is
cleared from the memory.
EXIT
Select EXIT to exit memory mode. You can also exit memory mode by pressing any button.
Softkeys (
1 2 3 4
)
Each setting on the measurement function knob may activate one or more softkey settings on the LCD. If there is more than one measurement for a function knob setting, a softkey menu appears on the display. Press the corresponding softkey to select the desired measurement.
Setup Menu
The Setup menu allows you to customize default settings. To activate the Setup menu, press and hold the yellow (shift) button for two seconds.
Use the softkeys as shown in the following table to edit setup values. Setup menu values are saved when you turn off the meter, except for reference values.
Softkey 1 + 2 3 4 OK
Function
Press to increase setting value
Press to decrease setting value
Press to step to next digit in settin g value
Press to sa ve setting and move to next setup parameter
26
Page 35
True RMS Digital Multimeters
Special Features
Table 2 lists the setup menu prompts, the definition of parameters, and default values.
Table 2. Setup Prompts, Definitions, and Default Values
Upper Display
Prompt
POFF Sets auto-off time (in minutes) 30 minutes LOFF Sets backlight auto-off time (in seconds) 60 seconds bEEP Toggles beeper on and off ON HrES Changes display to 50,000 counts OFF POL (Duty) Scrolls through OFF, POS (positive duty
EdGE (Hz) Toggles between POS (positive edge) and
1
rEF
(t)rEF(dB)
1
Meter must be in REL t or dB mode to access these setup parameters
1
(press OK to cycle through parameters)
factor), and NEG (negative duty factor)
NEG (negative edge) triggering in Hz measurement
Changes the reference value for delta measurements
Changes the reference value for dB measurements
Definition of Parameter
Default
Value
OFF
Positive (rising)
Value before REL t is pressed
1 V
Special Features
High Resolution (HrES) 50,000-Count Mode
By default, the meter is set to 5,000-count mode. For 50,000-count mode, press the yellow (shift) button when you turn on the meter. To change the default resolution to 50,000-count mode, use the Setup menu information in the "Setup Me nu" section.
The following measurements are limited to 5,000-count mode: 50 , 50 M 1 ms peak hold, AC + DC amps, AC DC amps, AC + DC volts, AC DC volts, capacitance, and Hertz dual display mode.
27
Page 36
183 & 185
Users Manual
Beeper
A single beep indicates correct operation. You can turn the single-beep feature off in the Setup menu. A double beep indicates a warning or error condition. A triple beep indicates the meter will auto-off in one minute. Continuous beeping indicates there is circuit continuity while in continuity mode. You can not disable double, triple, or continuous beeps.
Auto-Off
The auto-off feature automatically turns off the meter if no controls or settings are changed within a set amount of time. To turn on the meter a fter auto-off, press any button. The meter will return to the state it was in before auto-off occurred, but held values are lost.
Use the Setup menu to adjust the auto-off delay. The default auto-off time is thirty minutes. You can disable auto-off by pressing the meter or by using the Setup menu.
HOLD when you turn on
Auto-off is disabled during MIN MAX mode.
Power-Up Options
To activate power-up functions, press and hold a button or softkey when you turn on the meter. Hold the button or softkey until you hear a single beep and see a text acknowledgment on the display (see Table 3 below). The following table lists all power-up options. Most of the power-up option descriptions also appear on the rear panel.
When you turn off the meter, the power-up options are not saved. Use the Setup menu to change default settings.
28
Page 37
True RMS Digital Multimeters
Special Features
Table 3. Power-up Options
Button Power-up Function Explanation
RANGE
(HI
1
mV)
MIN MAX
(
1 SEC
1
)
RELt
(
bEEP
1
)
Shift (yellow button)
(
HrES
1
)
LIGHT
(
LOFF
1
)
Sets meter to 500 mV high impedance mode
Enables high impedance (> 10 MΩ) across the input jacks in the 500 mV DC range so that the device under test is not loaded when you measure small voltages.
Sets meter to 1 second MIN MAX
See "MIN MAX" information.
for more
mode Turns off beeper Double, triple, and continuity beeps
are not affected.
Sets meter to high resolution (50,000
See "High Resolution (HrES) 50,000­Count Mode" for further information.
count) mode
Disables light timeout --
Softkey
1
Displays software version and calibration date
Displays the software version (M.mm, where M is the major revision and mm is the minor revision). Press softkey 1 again to display the date the meter was last calibrated (upper display shows month and main display shows year).
29
Page 38
183 & 185
Users Manual
Table 3. Power-up Options (Cont.)
Button Power-up Function Explanation
Softkey 2 Overall Diagnostics Displays all LCD segments.
Press softkey 2 again to hear the beeper. Press softkey 2 again to perform button and knob diagnostics. The display shows two two-digit numbers. The numbers on the left confirm the knob location and the numbers on the right confirm the button operation. To exit diagnostics, turn off meter.
Softkey 3 LCD test Displays al l LCD segments so
you can verify corre ct LCD operation and display. Compare this to the LCD figure in the "Display Indicators" section.
Softkey 4 Battery test Displays the voltage across
the battery terminals. The meter will shut off at 1.5 V.
HOLD (
POFF
YELLOW and MIN MAX (
rESEt
1
)
)
Disables auto-off -­Resets meter to factory
default settings
You must press both buttons at the same time while powering on the meter.
1
The bolded text in parentheses in the Button column shows when the meter registers the power-up setting. Do not release the button until y ou either hear a single beep or see the text.
30
Page 39
True RMS Digital Multimeters
Special Features
MIN MAX AVG Operation
Press MIN MAX to start recording MIN MAX values. In 5,000 count mode the MIN MAX default recording rate is 4 measurements per second. Press and hold
MIN MAX when turning on the meter to apply averaging, which reduces
the recording rate to 1 measurement per second (1 sec MIN MAX). The
MIN MAX button cycles through the operations listed in Table 4.
Table 4. Min/Max Operations
Display
Indicator Description
M The live signal value is shown. The upper display shows the
elapsed time since the recording began.
MAX The MAX indicator and maximum value are shown. The upper
display shows the timestamp at which the maximum value occurred, relative to the start of the test.
MIN The MIN indicator and minimum value are shown. The upper
display shows the timestamp at which the minimum value occurred, relative to the start of the test.
MAX–MIN The MAX–MIN indicator and maximum value minus minimum
value are shown. The upper display shows the time difference between the MAX and MIN events.
AVG The AVG indicator is shown and the value shown is the
average value of all meter readings. The upper display shows the elapsed time since recording began.
31
Page 40
183 & 185
Users Manual
Once you set the meter to MIN MAX mode, the meter will uprange, or automatically increase range setting, but will not downrange. You must exit MIN MAX mode to restore downranging abilities to the meter.
While in MIN MAX mode, press most recent MIN MAX values. Press values. Press
HOLD a second time to reset and restart the MIN MAX
HOLD to stop the recording and freeze the
MIN MAX to cycle through the held
recording. While in MIN MAX mode, activate memory mode to hold the displayed MIN
MAX value for storage into memory without stopping or resetting the MIN MAX recording.
To exit MIN MAX mode and clear stored values, press and hold
MIN MAX for
two seconds.
Auto Fuse Detection
The meter automatically verifies the integrity of the internal fuse when you set the measurement function knob to A. If an open fuse is detected, the word
FUSE
See "Replacing the Fuse" for instructions on how to replace fuse F1.
shows on the main display.
32
Page 41
True RMS Digital Multimeters
Specifications
Specifications
All specifications are warranted, unless noted as typical, for the rated temperature range of 23 °C
Characteristics Description
LCD display digits 3 4/5 (default) or 4 4/5 Display counts 5,000 (default) or 50,000 Bargraph 20 segment, updated 20 times per
Memory locations 183: 10, 185: 30
± 5 °C at less than 80% relative humidity.
second
Out of range indicator
Low voltage indicator Battery symbol shows on LCD at 2.0 V.
Battery life 100 hours continuous use with
Auto-off Adjustable, 30 minute default Power source Two AA 1.5 V alkaline batteries
Maximum input voltage between terminals and between terminals and earth.
F1 fuse protection 11 A (1000 V) service-replaceable Backlight Green LEDs
1
If the meter is exposed to water have it inspected by qualified service
personnel.
OL
: overrange
Ur
: underrange
Meter powers down at 1.5 V.
backlight off (typical)
(NEDA 15 A) 1000 V RMS
1
33
Page 42
183 & 185
Users Manual
Table 5. DC Voltage Characteristics
Characteristic Description
Settling time 3 readings (typical) Reading rate 5,000 ct.: 4 readings per second
50,000 ct.: 1 reading per second
Rejection ratio
Common mode 120 dB at DC or 50 Hz or 60 Hz Normal mode 60 dB at 50 Hz or 60 Hz
Input impedance 10 M (typical)
Table 6. DC Voltage Range, Resolution, and Accuracy
Resolution Accuracy
Range
5,000
counts
50,000
counts 183 185
0.5 V 100 µV 10 µV
±(0.07% + 1
count)
1
± (0.05% + 1 count)
5 V 1 mV 100 µV 50 V 10 mV 1 mV 500 V 100 mV 10 mV 1000 V 1 V 100 mV Temperature coefficient Add (0.005% + 0.1 ct.)/°C to accuracy
beyond rated temperature range.
1
Accuracy in 50,000-count mode is % + 10 counts.
34
Page 43
True RMS Digital Multimeters
Specifications
Table 7. AC Voltage Characteristics
Characteristic Description
Input impedance 10 M in parallel with 100 pF (typical) Settling time 4 readings (typical) Reading rate 5,000 ct.: 4 readings per second
50,000 ct.: 1 reading per second Common mode rejection ratio 60 dB at DC to 60 Hz Crest fact or, maximum Full scale: 3
Half scale: 6 AC+DC1 total RMS volts accuracy AC (RMS) accuracy + 0.1% + 1 count AC DC1 dual display accuracy DC Accuracy + 0.05% + 1 count
AC RMS Accuracy + 0.1% + 1 count Upper display frequency (5,000 counts)
Accuracy ± (0.002% + 1 count) for 20 Hz to 20 kHz
Sensitivity 10% of selected voltage range dB reference dBm reference
1
5,000-count mode only.
2
See "dB and dBm Voltage Measurements" for dB and dBm calculations.
2
2
1 VRMS (adjustable) 775 mV across 600 Ω (1 mW)
35
Page 44
183 & 185
Users Manual
Table 8. AC Voltage Range, Resolution, and Accuracy
Resolution Accuracy
Range
5,000
Counts
50,000
Counts 183 185
0.5 V 100 µV 10 µV 5 V 1 mV 100 µV 50 V 10 mV 1 mV 500 V
1000 V
2
2
100 mV 10 mV
1 V 100 mV 40 Hz – 10 kHz:
AC: Add (0.03% + 0.1 ct.)/°C beyond rated
Temperature coefficient
temperature range. AC+DC: Add (0.06% + 0.1 ct.)/°C beyond rated
temperature range.
40 Hz – 20 kHz ± (0.6% + 2 counts):
± (0.6% + 2 counts)
1
40 Hz – 20 kHz: ± (0.4% + 2 counts)
40 Hz – 10 kHz: ± (0.4% + 2 counts)
1
Accuracy in 50,000-count mode is % + 20 counts.
2
For voltages > 100 V, the maximum volts–Hz product < 1 X 107 VHz.
Table 9. DC Current Characteristics
Characteristics Description
Burden voltage 5 mA to 5 A: 0.3 V max.
10 A: 0.5 V max.
Percent 4-20 mA (calculated in 50 mA range)
4 mA = 0%
20 mA = 100% Settling time 4 readings (typical) Reading rate 5,000 ct.: 4 readings per second
50,000 ct.: 1 reading per second
36
Page 45
True RMS Digital Multimeters
Table 10. DC Current Range, Resolution, and Accuracy
Resolution Accuracy
50,000
Range 5,000 Counts
Counts 183 185
Specifications
500 µA 100 nA 10 nA ± (0.2% + 4 counts) 5 mA 1 µA 100 nA
± (0.2% + 2 counts) 50 mA 10 µA1 µA 500 mA 100 µA 10 µA 5 A 1 mA 100 µA ± (0.4% + 2 counts)
10 A for 3 minutes
10 mA 1 mA ± (0.8% + 2 counts)
(15 A for 30 sec.) Allow 10 minutes of cooling between measurements
Temperature coefficient
1
Accuracy in 50,000-count mode is % + 40 counts.
2
Accuracy in 50,000-count mode is % + 20 counts.
Add (0.05% + 0.1 ct.)/°C beyond rated temperature range.
Table 11. AC Current Characteristics
1
2
2
2
Characteristics Description
Burden voltage 0.5 mA to 5 A: 0.9 V max.
10 A: 1.0 V max.
AC+DC1 Accuracy AC RMS amps accuracy + DC amps
accuracy Upper display frequency Accuracy ± (0.002% + 1 count) for 20 Hz to 5 kHz Sensitivity 10% of range Settling time 4 readings (typical) Reading rate 5,000 ct.: 4 readings per second
50,000 ct.: 1 reading per second
1
5,000-count mode only.
37
Page 46
183 & 185
Users Manual
Table 12. AC Current Range, Resolution, and Accuracy
Resolution Accuracy
Range
5,000
Counts
50,000
Counts 183 185
0.5 mA 100 nA 10 nA 5 mA 1 µA 100 nA 50 mA 10 µA1 µA 500 mA 100 µA 10 µA 5 A 1 mA 100 µA 10 A for 3 minutes
10 mA 1 mA (15 A for 30 sec.) Allow 10 minutes of cooling between measurements
1,2
40 Hz – 1 kHz:
± (0.6% + 2 counts)
1 kHz – 5 kHz:
± (7.5% + 2 counts)
Temperature coefficient Add (0.05% + 0.1 ct.)/°C beyond rated
temperature range.
1
Accuracy in 50,000-count mode is % + 20 counts.
2
> 5% of range.
Table 13. Resistance (Ω) Characteristics
Characteristics Description
Update rate 5,000 ct.: 2 readings per second
50,000 ct.: 1 reading per second 50 M: 1 reading per second
Settling time 50 to 5 Mrange: 3 readings (typical)
50 Mrange: 4 readings (typical) Compliance voltages (typical) 0.6 V (50 and 500 range is 1.3 V) Common mode rejection ratio 60 dB at DC, 50 Hz, or 60 Hz Normal mode rejection ratio 20 dB at 50 Hz
38
Page 47
True RMS Digital Multimeters
Specifications
Table 14. Resistance Range, Resolution, and Accuracy
Resolution Accuracy
Range 5,000 Counts 50,000 Counts 183 185
50 0.01
1
–– ± (0.1% + 10
counts)
500 0.1 0.01 Ω± (0.1% + 4
counts)
2
5 k 1 0.1 Ω± (0.1% + 2
counts)
3
50 k 10 1 500 k 100 10 5 M 1 k 100 Ω± (0.4% + 4
counts)
2
50 M 10 k –– ± (1.0% + 4
counts)
2
Temperature coefficient 50 to 500 k: Add (0.03% + 0.1 ct.)/°C
beyond rated temperature range. 5 MΩ to 50 MΩ: Add (0.2% + 0.1 ct.)/°C
beyond rated temperature range.
1
5,000 count mode only.
2
Accuracy in 50,000-count mode is % + 40 counts.
3
Accuracy in 50,000-count mode is % + 20 counts.
Table 15. Continuity Characteristics
Characteristics Description
Beeper sounds when resistance is 100 Ω or
Continuity threshold
less (typical)
Response time < 1 ms
39
Page 48
183 & 185
Users Manual
Table 16. Diode Test Characteristics
Characteristics Description
Test current (typical) 0.35 mA Test voltage 3.3 V maximum, open circuit Accuracy ± 1.0%
Table 17. Capacitance Range, Resolution, and Accuracy
(5,000 counts only)
2
Range Resolution
3
5 nF
1 pF ± (1.0% + 5 counts) (using REL t mode)
Accuracy
1
183 185
50 nF 10 pF ± (1.0% + 3 counts) (using REL t mode) 500 nF 100 pF
± (1.0% + 3 counts) 5 µF1 nF 50 µF 10 nF
± (3.0% + 3 counts) 500 µF 100 nF 5 mF 1 µF 50 mF 10 µF Temperature
Add (0.05% + 0.1 ct.)/°C beyond rated temperature range.
coefficient
1
5,000 count mode only.
2
> 1% of range.
3
± (1% + 10) below 0.500 nF
40
Page 49
True RMS Digital Multimeters
Specifications
Table 18. Frequency Characteristics, Resolution, and Accuracy
Characteristics Description
Signal coupling AC Minimum frequency 0.5 Hz Maximum frequency 1 MHz Accuracy ± (0.002%) + 1 count Best resolution 10,000 count: 0.01 Hz
100,000 count: 0.001 Hz
Temperature coefficient Add 0.00004%/°C beyond rated temperature
range.
Table 19. Frequency Voltage Range
Range Sensitivity, 10 Hz - 100 kHz Sensitivity, 1 MHz
1
500 mV 100 mV ––
5 V 500 mV 2 V 50 V 5 V 20 V 500 V 50 V ––
1
For voltages > 100 V, the maximum volts–Hz the meter is < 107 VHz.
Table 20. Duty Factor Characteristics
Characteristics Description
Range 1 Hz to 100 kHz Accuracy ± (0.1% + 0.05% per kHz) for 5 V input (logic
signals only) Signal coupling DC Resolution 0.1% Sensitivity 30% of range
41
Page 50
183 & 185
Users Manual
Table 21. Temperature Characteristics
Characteristics Description
Main di splay Range –50 °C to +980 °C
Accuracy ± 3 °C1 (typical) Thermocouple type K Upper display
Accuracy ± 3 °C of ambient temperature (typical)
1
Use the water and ice offset calibration method in the "Temperature
Measurements (185 only)" section for accuracy to ±1.0 °C.
Table 22. FAST MIN MAX (1 ms)Characteristics
Characteristics Description
Accuracy
1
Specified voltage or current measurement ± 30 counts of the peak value of a single 1ms pulse.
1
5,000-count mode only.
Table 23. Physical Characteristics
Characteristic Description
Dimensions (H × W × D) 38 mm × 88 mm × 183 mm (without holster) Weight (with batteries) 383 g (13.5 oz) With holster 539 g (1 lb 3 oz)
42
Page 51
True RMS Digital Multimeters
Table 24. Environmental Characteristics
Characteristic Description
Temperature
Operating –10 to +50 °C
Non-operating (storage) –40 to +60 °C
Humidity –40 to +35 °C: < 80%
+35 to +40 °C: < 70% +40 to +60 °C: < 55%
Altitude
Operating 2,000m (6,562 ft)
For altitudes from 2,000 m up to 3,000 m (9,843 ft) derate voltage input to 600 VAC CAT III.
Specifications
Non-operating (storage) 12,300 m (40,354 ft) Vibration
Operating 2.66 gRMS, 5 to 500 Hz, 3 axes
(10 minutes each)
Non-operating 3.48 gRMS, 5 to 500 Hz, 3 axes
(10 minutes each)
W Warning
This meter is sensitive to strong external magnetic fields. Do not use the meter within 1-inch (2.54 cm) of strong
external magnetic fields such as that produced by the Fluke ToolPak hanging magnet accessory. Incorrect readings may result. If erratic behavior is noted, turn meter off to reset.
43
Page 52
183 & 185
Users Manual
Category Standards or description
Table 25. Certifications and Compliances
EC Declaration of Conformity
– EMC
Australia/New Zealand Declaration of Conformity – EMC
EC Declaration of Conformity – Low Voltage
Meets intent of Directive 89/336/EEC for Electromagnetic Compatibility. Compliance was demonstrated to the following specifications as listed in the Official Journal of the European Communities:
EN 61326 Class A
1,2
Complies with EMC provision of Radio communications Act per the following standard(s):
AS/NZS 2064.1/2 Class A Radiated Emissions
Compliance was demonstrated to the following specification as listed in the Official Journal of the European Communities:
Low Voltage Directive 73/23/EEC as amended by 93/69/EEC. EN 61010-1/A2:1995
Safety requirements for electrical equipment for measuring control, and laboratory use.
U.S. Nationally Recognized Testing Laboratory Listing
ANSI/ISA S82.01-1994 CAN/CSA C22.2 No. 1010.1
Safety requirements for electrical equipment for measurement, control, and laboratory use
Additional Compliance IEC61010-1/A2:1995
Safety requirements for electrical equipment for measurement, control, and laboratory use.
44
Page 53
True RMS Digital Multimeters
Table 25. Certifications and Compliances (cont.)
Category Standards or description
Specifications
Installation Category DUAL RATINGS
Complies with IEC 1010-1 to 1000 V Overvoltage Category III, Pollution Degree 2; and IEC 664-1 to 600 V Overvoltage Category IV, Pollution Degree 2
OVERVOLTAGE (Installation) Categories refer to the level of Impulse Withstand Voltage protection provided at the specified Pollution Degree.
Overvoltage Category III equipment is equipment in fixed installations. Examples include switch gear and polyphase motors.
Overvoltage Category IV equipment is equipment for use at the origin of the installation. Examples include electricity meter and primary over-c urrent protection equipment.
Pollution Degree A measure of the contaminates that could occur in the
environment around and within a meter. Typically the internal environment inside a meter is considered to be the same as the external. Meters should be used only in the environment for which they are tested.
Pollution Degree 2 Normally only dry, nonconductive pollution occurs.
Occasionally a temporary conductivity that is caused by condensation must be expected. This location is a typical office/home environment. Temporary condensation occurs only when the meter is out of service.
Pollution Degree 3 Conductive pollution, or dry, nonconductive pollution
that becomes conductive due to condensation. These are sheltered locations where neither temperature nor humidity is controlled. The area is protected from direct sunshine, rain, or direct wind.
1
Add 25 counts (250 counts in 50,000 count mode) to the accuracy
specifications when in the presence of an RF field as defined in IEC801–3.
2
Amps DC: Add 60 counts (600 counts in 50,000 count mode) to the amps accuracy specifications when in the presence of an RF field as defined in IEC801–3.
45
Page 54
183 & 185
Users Manual
Accessories
This section lists all standard accessories for the 183 and 185 true RMS digital multimeters.
Table 26. Standard Accessories
Standard accessory Product or part number
Test lead set TL75, or equivalent Test leads
(1 red, 1 black) Alligator clips (185 only)
(1 red, 1 black) Protective Holster PN 1556861
Installed dry cell batteries - Two AA 1.5 V alkaline batteries (IEC
W Fuse (installed) 11 A, 1000 VRMS
Users Manual
Language Part Number
English English, French, Spanish,
Portuguese English, French, German, Italian,
Dutch
Certified to 1000 V CAT III
AC70 (red) PN 738120 AC70 (black) PN 738047
LRG or ANSI/NEDA 15A) PN 803293
FUSE, 11A, 1000V
1574586 1574599
1574607
English, Simplified Chinese, Traditional Chinese, Korean, Japanese
English, Danish, Finnish, Norwegian, Swedish
46
1574629
1587740
Page 55
True RMS Digital Multimeters
Setup for Optional Computer Interface Accessory (FlukeView Forms)
Setup for Optional Computer Interface Accessory (FlukeView Forms)
Follow the steps below to set up the computer interface accessory (see Figure 8):
1. Press the plastic receptacle into place in the top of the DMM protective
holster. Connect the FlukeView cable to the plastic receptacle.
2. Connect the other end of the FlukeView cable to your computer using the
9-pin connector. If you require a 25-pin connection to your PC, you will need to use a 9-pin-to-25-pin adapter.
3. Insert FlukeView Forms CD-ROM into your computer drive and proceed
with software installation. Refer to the FlukeView Forms documentation for further instructions on using Fl ukeView Forms.
You can find further information about FlukeView Forms features on the FlukeView Forms CD-ROM.
Plastic receptacle
Figure 8. Setup for the Optional Computer Interface Accessory
Cable
9–pin connector
ahr18f.eps
47
Page 56
183 & 185
Users Manual
Using Protective Holster and Tilt-Stand
ahr19f.eps
Figure 9. Holster and Tilt Stand
Battery Replacement
When you replace a battery, the meter calibration is not affected and the stored data is not lost.
Refer to Figure 10 to replace the battery. Remove the battery cover only in a clean, dry environment. See Table 26 for the descriptions and part numbers of the replaceable batteries.
48
Page 57
TRUE RMS MULTIMETER
185
True RMS Digital Multimeters
Servicing the Meters
4
F
3
F
2
F
1
F
Hz
V
RANGE
MIN MAX
FAST MN MX
HOLD
REL
A
MEMORY
V
COM
OFF
A
10A MAX
FUSED
1
Hz
CAT
1000V
2
ahr20f.eps
A Batteries (2 AA alkaline or rechargable) B Battery Cover
Figure 10. Replacing the Batteries
Servicing the Meters
Only qualified personnel should perform service procedures. Read the Safety Information section before performing any service procedures.
WWarning
Do not service alone. Do not perform internal service or
adjustments of this meter unless another person capable of rendering first aid and resuscitation is present.
Use care when servicing with power on. Dangerous
voltages or currents may exist in this meter. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed
connections.
Service only in a clean, dry environment.
Annual calibra tion verification is recommended.
Installing improper fuses can cause injury and meter
damage.
49
Page 58
183 & 185
Users Manual
Replacing the Fuse
Follow the steps below to access and replace the service-replaceable fuse:
1. Remove the battery cover. Remove the batteries and two screws on both
sides of the batteries (see Figure 11).
Remove 2 screws
(1566978)
Remove gasket
(1567042)
Figure 11. Opening the Case
2. Carefully insert a screwdriver between the gasket and meter case and
gently li ft and remove the gasket. You must re move the gasket before opening the meter case.
3. Carefully lift the rear panel of the meter up to access the fuse F1 (see
Figure 12). Remove and replace the fuse. Refer to Table 26 for more information on which fuse to use.
WWarning
Installing improper fuses can cause injury and meter damage.
4. Verify meter calibration after replacing F1.
ahr21f.eps
50
Page 59
True RMS Digital Multimeters
General Care and Cleaning
Fuse F1
ahr22f.eps
Figure 12. Fuse Access
General Care and Cleani ng
Caution
Protect the meter from adverse weather conditions.
Do not expose the LCD display to direct sunlight for long
periods of time. To avoid damage to the meter, do not expose the interior
of the meter to sprays, liquids, or solvents.
Clean the exterior of the meter by removing dust with a lint-free cloth. Use care to avoid scratching the clear plastic display filter.
For further cleaning, use a soft cloth or paper towel dampened with water. You can use an alcohol-free glass cleaner for more efficient cleaning.
Caution
To avoid damage to the surface of the meter, do not use abrasive or chemical cleaning agents.
51
Page 60
183 & 185
Users Manual
WWarning
The meter is not protected from exposure to water. Exposing the meter to water can create a shock hazard.
If the meter is exposed to water, open the case and allow the meter to fully dry. To open the meter, use the procedure in the "Servicing the Meters" section.
52
Loading...