Fluke 113 Data Sheet

Fluke 113
N10140
R
Utility Multimeter
Technical Data
True RMS Utility Multimeter designed for basic electrical tests
The new 113 Utility Multimeter has the features needed to repair most electrical problems. This meter is simple to use and has significant improvements over Fluke’s original 7-600, and other utility multimeters. With features such as Fluke’s VCHEK™, added measurement functions, backlight, conformance to the latest safety standards, and a much larger display that’s easier to view, this new meter is a must have for the utility users toolbox.
Features include:
VCHEK™ LoZ low impedance measurement function to
simultaneously test for voltage and continuity
True-rms for accurate ac measurements on non-linear loads
Record signal fluctuations using the Min/Max function
Diode test for testing general-purpose germanium, silicon,
and power diodes
Integral holster with probe holders for easy storage
Auto and Manual ranging for added user functionality
Meets Measurement Category CAT III 600 V and
Category IV 300 V standards for a higher level of safety
The optional TPAK magnetic hanger allows the user hands-free
flexibility
Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %. Accuracy specifications are given as follows:
Note:
Specifications are subject to change without notice. ± ( [ % of reading ] + [ number of least significant digits ] )
Function Range Resolution Accuracy
DC, 45 to 500 Hz 500 Hz to 1 kHz
1,2
Chek
Function
3
3
3
3
Notes:
1
All Chek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2
Crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3
After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test,
and continuity.
Maximum voltage between any terminal and earth ground
Display 3 3/4-digits, 6000 counts, updates 4/sec Operating temperature -10 °C to 50 °C (14 °F to 122 °F) Storage temperature -40 °C to 60 °C (-22 °F to 140 °F) Temperature coefficient 0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C) Operating altitude 2,000 m Storage altitude 10,000 m Relative humidity 95 % to 30 °C
Battery type 9 Volt Alkaline, ANSI 1604A / IEC 6F22 Battery life Alkaline: 300 hours typical, without backlight Shock 1 Meter drop per IEC 61010-1-2001 Vibration Per MIL-PRF-28800 for Class 2 instrument Size (HxWxL) 167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in) Weight 13.0 oz (404 g) Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No
EMI regulations Complies with FCC Part 15, Class B
Function Input Impedance (Nominal)
Chek
> 60 dB at dc, 50 or 60 Hz
6.000 V
60.00 V
600.0 V
Range Resolution Accuracy
2.000 V 0.001 V 2.0 % + 3
600.0
6.000 k
60.00 k 1000 nF
10.00 µF
100.0 µF 9999 µF
Common Mode Rejection Ratio (1 k Unbalanced)
Open Circuit Test Voltage Full Scale Voltage
< 2.7 V dc < 0.7 V dc < 2.7 V dc 2.000 V dc
2 Fluke Corporation 113 Utility Meter
0.001 V
0.01 V
0.1 V
0.1
0.001 k
0.01 k 1 nF
0.01 µF
0.1 µF 1 µF
600 V
75 % to 40 °C 45 % to 50 °C
61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
~3 k < 300 pF
Short Circuit Current
< 350 µA < 1.0 mA
2.0 % + 3 4.0 % + 3
Beeper on < 20 , off > 250 ; detects
opens or shorts of 500 µs or longer
0.9 % + 2
0.9 % + 1
0.9 % + 1
1.9 % + 2
1.9 % + 2
1.9 % + 2 100 µF - 1000 µF: 1.9 % + 2 > 1000 µF: 5 % + 20
Ordering information
Fluke 113 Utility Meter
Included
Fluke 113 Utility Multimeter TL75 Test Leads One 9V Battery Printed Users Manual
Fluke. Keeping your world up and running.
Fluke Corporation PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2008 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 3/2008 3292015 D-EN-N Rev A
®