Fluke 112, 111, 110 Datasheet

Want to compare sizes? These little meters pack more features than some DMMs twice their size. True-rms ac voltage and current readings, for example. 6000 count resolution. Min/Max/Average. And frequency and capaci­tance capabilities. Plus they give you an easy-open battery access door. They’re all CAT III rated for 600V and are protected by a three-year warranty. The 112 model has a backlight and delivers
0.7% basic dc accuracy. The price? They’re less than you think. Yes, smaller is better. Definitely. Pick one up at your nearest distributor or click into www.fluke.com/110.
Fluke. Keeping your world
up and running.
Sometimes
smaller is better
.
Work faster with hang-ups.
Get our ToolPak strap and magnet for hanging your meter from almost anything while you work.
Designed and Conforms to
IEC 1010-1
600V
CAT III
N10140
©2000 Fluke Corporation. U.S. (800) 44-FLU KE. Fax back (800) FLUKE FAX. Canada (800) 36-FLU KE. Europe (31 40) 2 675 200. Other countries (425) 446-5500. All rights reserved. www.fluke.com
Pending
R
Features 110 111 112
Basic dc accuracy of 0.7%
6000 count display
Manual reading hold for user convenience
IEC 1010 Rating: CAT III 600V
Compatible with Fluke ToolPak™ meter hanging kit
Backlight for measurements in low visibility environments
Battery door provides battery access without breaking the calibration seal
•••
•••
•••
•••
•••
•••
Fluke 110 Fluke 111 Fluke 112
Range N/A 0.01 mA to 10.00A 0.01 mA to 10.00A
Continuity
Hz
Accuracy N/A ± (1.5% of reading ± (1.5% of reading
Crest Factor N/A ≤ 3 ≤ 3
AC Response N/A 50 Hz to 500 Hz 50 Hz to 500 Hz
Range N/A 0.001A to 10.00A 0.001A to 10.00A
Accuracy N/A ± (1.0% of reading ± (1.0% of reading
Range 300 mV to 600V rms 1 mV to 600 mV rms 1 mV to 600 mV rms Accuracy ± (1.0% of reading ± (1.0% of reading plus
AC Response 50 Hz to 500 Hz 50 Hz to 500 Hz 50 Hz to 500 Hz
Range 1 mV to 600V 1 mV to 600V 1 mV to 600V Accuracy ± (0.7% of reading ± (0.7% of reading ± (0.7% of reading
Range 0.1 to 40.00 M 0.1Ω to 40.00 M 0.1Ω to 40.00 M Best Accuracy ± (0.9% of reading ± (0.9% of reading ± (0.9% of reading
Range 1 nF to 9999 µF 1 nF to 9999 µF 1 nF to 9999 µF Best Accuracy ± (1.9% of reading ± (1.9% of reading ± (1.9% of reading
Range Voltage Input: Voltage Input: Voltage Input:
Accuracy ± (0.1% of reading ± (0.1% of reading ± (0.1% of reading
plus 3 counts) 3 counts) Not specified 3 counts) Not specified
plus 2 counts) plus 2 counts) plus 2 counts)
plus 1 count) plus 1 count) plus 1 count)
plus 2 counts) plus 2 counts) plus 2 counts)
Beeper guaranteed on <20, guaranteed off >250Ω;
detects opens or shorts of 250 µs or longer
5 Hz to 50 kHz 5 Hz to 50 kHz 5 Hz to 50 kHz
plus 2 counts) plus 2 counts) plus 2 counts)
plus 3 counts) plus 3 counts)
Not specified below 3A Not specified below 3A
(20A overload for (20A overload for
30 seconds) 30 seconds)
plus 3 counts) plus 3 counts)
± (1.0% of reading plus
below 300 mV below 300 mV
Current Input: Current Input:
50 Hz to 5 kHz 50 Hz to 5 kHz
Dealer Stamp
Available Fluke Accessories 110, 111, 112
Meter Hanging ToolPak magnet and strap kit
Cases C510 leather meter case
Test Leads All Fluke Accessory Test Leads
Temperature 80TK Thermocouple Module
Specialty 80K-6, 80K-40 High Voltage Probes
C12A padded meter case C20 hard meter case
80-150U Univ. Temp Probe
PV 350 Pressure Module FOM Fiber Optic Meter
For detailed specifications contact your local Fluke representative, or visit www.fluke.com. Specifications are subject to change without notice.
Fluke. Keeping your world
up and running.
©2000 Fluke Corporation. All rights reserved. 11/2000 1605199 D-ENG-N Rev A
Loading...