Page 1 of 3, Document #2156
110 Series True-rms DMMs
Extended Specifications
©2000 Fluke Corporation
Rev. A-11/2000
True-rms Digital Multimeter
Model Differences
(all other specifications are the same for each model)
Feature Model
Current Measurement ••
Backlight •
Nominal Specifications
Function Absolute Range or Description
AC Voltage, True-rms 300 mV to 600.0V (50 Hz to 500 Hz)
DC Voltage 1 mV to 600.0V
Continuity Beeper guaranteed on < 20Ω, guaranteed off > 250Ω;
Resistance 0.1Ω to 40.00 MΩ
Diode Test 2.200V, 0.9% + 2 digits, audible feedback
Capacitance 1 nF to 9999 uF
AC Current, True-rms NA 0.01A to 10.00A
DC Current NA 0.001A to 10.00A
Frequency of Voltage 5 Hz to 50 kHz
Frequency of Current NA 50 Hz to 5 kHz
Basic DC Voltage Accuracy 0.7%
Basic AC Voltage Accuracy 1.0%
Fluke 110 Series
Extended Specifications
110 111 112
Model 110 Models 111 and 112
detects opens or shorts of 250 µs or longer.
(20.00A overrange for 30 seconds)
(20.00A overrange for 30 seconds)

Page 2 of 3, Document #2156
110 Series True-rms DMMs
Extended Specifications
©2000 Fluke Corporation
Rev. A-11/2000
Features
Feature Description
Backlight (Model 112 only) Automatically extinguishes after 2 minutes to save battery life
HOLD Display hold, freezes the display at the push of a button
MIN MAX AVG Minimum, maximum, and average reading memory
Manual or auto ranging In auto range, the meter selects the range with the best resolution for
Fast continuity/open detection The beeper sounds with a stretched pulse for opens or shorts as
Beeper Used in continuity and diode test functions, to signal new minimum and
Test lead alert The message “LEAD” appears briefly on the display when the rotary switch
Power-up options (1) Turn on all LCD segments, (2) Disable beeper, (3) Disable sleep mode,
Closed-case calibration No internal adjustments needed
Probe holders The standard-equipment protective holster has probe holders on the sides
Battery access door The battery is replaced easily by removing one Phillips head screw that
Replaceable fuse (111 and 112) A user-replaceable heavy-duty ceramic fuse protects the DMM from
The high-impact case The 110 Series DMMs are tested to withstand a drop of
and protective holster 1 meter to a hard surface
The timeout feature can be disabled with a power-up option
the present measurement value
brief as 250 µs
maximum in MIN MAX mode, and to signal valid and invalid button presses
is moved to or from any A (Amps) position
(4) Disable backlight timeout (Model 112 only)
for probe storage and for convenience when making measurements
fastens a battery door on the meter’s back cover
application of excessive current to the A (Amps) input jack. Use the exact
replacement fuse as stated on the meter back cover
Detailed Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity
at 0% to 75%.
The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )
Maximum voltage between any 600V
terminal and earth ground
Surge Protection 6 kV peak per IEC 61010-1-95
Fuse for A input (111 and 112) 11A, 1000V F AST Fuse, minimum interrupt rating 17000A
Display Digital: 6,000 counts, updates 4/sec
Temperature Operating: -1 0°C to +50°C
Temperature Coefficiant 0.1X (specified accuracy/°C) (<18°C or >28°C)
Electromagnetic Compatibility Performance ≥ 3 V/m is not specified
Relative Humidity Noncondensing < 10°C
Battery Life Alkaline: 300 hrs typical, without backlight
Size, with Holster (H x W x L) 4.6 cm x 9.6 cm x 16.0 cm
Weight 350g
Safety Compliances ANSI/ISA-S82.01-1988, CSA C22.2 No 231 and IEC 61010-1-95
Warranty Three years
Certifications UL (3111), , CSA, TÜV, (N10140)
Bar Graph: 33 segments, updates 40/sec
Frequency: 9,999 counts
Capacitance: 9,999 counts
Storage: -30°C to +60°C
0% to 95% @ 10°C to 30°C
0% to 75% @ 30°C to 40 °C
0% to 45% @ 40°C to 50°C
Overvoltage Category III (CAT III), 600V