TECHNICAL DATA
Fluke 107 Palm-sized,
CAT III Digital Multimeter
Professional measurements in the palm of your
hand
The Fluke 107 is a compact, easy-to-use multimeter made to fit
the way you work. It is the perfect first-pass troubleshooting tool:
small enough to fit in a shirt pocket or work bag, tough enough
to withstand daily use, and extremely simple to use. All without
compromising safety. For everyday applications, where true-rms
accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time.
Product highlights
• AC/DC voltage to 600 V
• AC/DC current to 10 A
• Resistance and Continuity to check for broken wires
• Data hold and backlit display to keep you working safe and fast
Electrical specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of
18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take
the form of: ±([% of Reading] + [Number of Least Significant Digits])
Function Range
AC volts
(40 Hz to 500 Hz)
SIZE (H X W X L)
142 mm x 69 mm x 28mm
WARRANTY
1-year
FLUKE 107 COMPLETE TEST FUNCTIONS
• Including AC and DC voltage measurement
• AC and DC current measurement
• Resistance measurement
• Capacitance measurement
• Diode measurement
• Frequency and duty cycle test and other
functions to meet basic electrical maintenance,
electrical measurement, and electronic
measurement applications
DC volts
AC millivolts 600.0 mV 0.1 mV 3.0 % + 3
Diode test 2.000 V 0.001 V 10 %
Resistance (ohms)
Capacitance
Frequency
(10 Hz to 100 kHz)
Duty cycle 0.1 % to 99.9 % 0.1 % 1 % typ ic al
AC current
(40 Hz to 200 Hz)
DC current
Backlight — — Yes
All AC, Hz, a nd duty c ycle are spec ified from 1 % to 100 % of range. Inputs below 1 % of range are not
specified.
Typical ly, open circuit test voltage is 2.0 V and shor t circuit c urrent is < 0.6 m A.
Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5
nF in the 50 nF range).
All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not
specified.
Typical means when the frequenc y is at 50 Hz or 60 Hz and the duty cycle is bet ween 10 % and 90 %.
6.000 V
60.00 V
600.0 V
6.000 V
60.00 V
600.0 V
400.0
4.000 k
40.00 k
400.0 k
4.000 M
40.00 M
50.00 nF
500.0 nF
5.000 F
50.00 F
500.0 F
1000 F
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 k Hz
4.000 A
10.00 A
4.000 A
10.00 A
Resolution Accuracy
0.001 V
0.01 V
0.1 V
0.001 V
0.01 V
0.1 V
0.1
0.001 k
0.01 k
0.1 k
0.001 M
0.01 M
0.01 n F
0.1 nF
0.001 F
0.01 F
0.1 F
1 F
0.01 H z
0.1 Hz
0.001 k H z
0.01 k H z
0.1 kHz
0.001 A
0.01 A
0.001 A
0.01 A
1.0 % + 3
0.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
0.1 % + 3
1.5 % + 3
1.5 % + 3
Specifications continued
Electrical specifications
Function
AC volts 600 V
AC millivolts 600 mV
DC volts 600 V
6 x 105 V H z Max
For mV (AC), input impedance is approximately 1 M.
Overload
protection
General specifications
Maximum voltage between any terminal and earth ground 600 V
Display (LCD) 6000 counts, updates 3/sec
Battery type 2 AAA, NEDA 24A, IEC LR03
Battery life 200 hours minimum
Temperature Operating: 0 °C to 40 °C
Relative humidity Operating Humidity: Non-condensing when < 10°C
Altitude Operating: 2000 m
Temperature
coefficient
Fuse protection for
current inputs
Size (HxWxL) 142 mm x 69 mm x 28mm
Input impedance
(nominal)
> 10 M
< 100 pF
>1M
<100 pF
> 10 M
< 100 pF
Common mode
rejection ratio
> 60 dB at dc, 50 Hz or
60 Hz
> 80 dB at
50 Hz or 60 Hz
> 100 dB at dc, 50 Hz or
60 Hz
Normal mode rejection
ratio
Storage: -30 °C to 60 °C
≤ 90 % at 10 °C to 30 °C;
≤ 75 % at 30 °C to 40 °C
Operating Humidity, 40 M Range:
≤ 80 % at 10 °C to 30 °C;
≤ 70 % at 30 °C to 40 °C
Storage: 12,000 m
0.1 X (specified accuracy)/°C
(< 18 °C or > 28 °C)
11 A, 1000 V Fast Fuse, Fluke
specified part only
> 45 dB at
50 Hz or 60 Hz
—
—
Weight 200 g
IP rating IEC 60529: IP 40
Safety IEC 61010-1: 600 V CAT III, Pollution Degree 2
Electromagnetic
IEC 61326-1: portable
environment
Electromagnetic
compatibility
Applies to use the Korea only.
Class A Equipment
(Industrial broadcasting and
communication equipment)
Warranty One year
This product meets requi rements for indu strial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intendedfor use in business
environments and is not to be used in home.
Ordering information
FLUKE-107 ESP Palm-sized, CAT III Digital
Multimeter
Included equipment
TL75 Hard Point™ Test Lead Set
Two AAA Batteries (installed)
SmartStrap™ Intelligent Magnetic
Multi-purpose Lanyard
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
Modification of this document is not
permitted without written permission
from Fluke Corporation.
For more information call:
In the U.S.A. (800) 443-5853 or
®
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0)40 267 5100 or
Fax +31 (0)40 267 5222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2013, 2019 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 9/2019 6000021c-en