FEC FEC-100WMK, FEC-100WMW Installation Manual

FEC
BRACKET
MODEL FEC-100WMK (BLACK) OR FEC-100WMW (WHITE) WALL MOUNT BRACKET KIT FOR USE WITH PANASONIC AWUE-100 CAMERA
"INSTALLATION CAMERA WITHOUT REAR CAMERA COVER"
HEIGHT 6.41 WIDTH 7.46 DEPTH 8.07
PANASONIC
MOUNT CAMERA TWIST LOCK PLATE TO BRACKET WITH (4) 8-32 X 1/4" SCREWS
1
AS AN OPTION, THE WALL BRACKET MAY ALSO BE ATTACHED TO A 1 GANG, 2GANG OR 4" SQUARE EO BOX.
(DO NOT USE EO BOX AS SOLE SUPPORT. WALL MOUNT BRACKET MUST BE SECURED WITH SUFFICIENT SIZE SCREWS
2
THROUGH THE .25" DIAMETER. MOUNTING HOLES.)
MOUNT BRACKET TO WALL USING APPROPRIATE HARDWARE THROUGH THE .25" MOUNTING HOLES. USE 1/4 x 2 1/2" LAG BOLTS FOR WOOD WALL STUDS. ROUTE CABLES THROUGH WIRE MANAGEMENT PORTS.
3
(MAKE CERTAIN THAT MOUNTING METHOD IS SECURE AND FOLLOWS ACCEPTED NORMS FOR THIS APPLICATION)
MOUNT CAMERA TO TWIST-LOCK CAMERA BRACKET PER CAMERA INSTRUCTIONS
4
FINISH SECURING CAMERA TO MOUNTING PLATE WITH (1) SCREW SHIPPED WITH CAMERA
5
ATTACH DROP PREVENTION WIRE PER CAMERA INSTRUCTIONS, CONNECT CABLES.
AW-UE100 INS
TRUCTIONS
1
STEP 1
ATTACH BRACKET WITH (4) 8-32 X 1/4" SCREWS
NOTE: THIS 1/4-20 X 1/2" SCREW ONLY USED TO SECURE CAMERA WHEN NO BRACKET IS USED
2
STEP 2
HOLE SET FOR ATTACHING TO 1 & 2 GANG EO BOXES
HOLE SET FOR ATTACHMENT TO 4" SQUARE EO BOX
STEP 3
3
LAG BOLT
4
STEP 4
PLACE CAMERA ON MTG BRACKET & TWIST TO LOCK IN POSITION
9.17
5
STEP 5
NOTE: REFER TO CAMERA INSTRUCTIONS WHERE DROP PREVENTION WIRE ATTACHES (SHIPS WITH CAMERA)
INSTALL 3MM SCREW FLAT & LOCK WASHER TO SECURE CAMERA TO MOUNTING BRACKET (THIS HARDWARE SHIPS WITH CAMERA)
SAFETY NOTE:
- Before beginning the installation, it is very important to examine the unit for damage, defects and correct hardware.
- The Installation instructions must be read and entirely understood prior to install.
- It must be determined that the mounting surface is capable of supporting the mount and equipment.
- The Professional Installer must determine the proper way to attach the WALL BRACKET MODEL
- The installation of the mount and equipment is dependent on proper/secure attachment and is the responsibility of the installer.
- Make sure wall will support 4 times the combined weight of Equipment and Wall Mount.-
- This mount should be attached to wood studs only. Under no circumstances should this product be mounted to metal studs, unless an installation professional deems they have been adequately reinforced and will support 4 times the combined weight of Equipment and the Wall Mount.
- Please use only the bolts supplied with the unit or bolts of the correct size, making sure the hardware used is tightened properly for a secure installation..
- The WALL BRACKET MODEL is only intended to be used with the equipment listed on the install sheet. It is not meant to be used with any other equipment.
- If at anytime, a question arises regarding this installation (or regarding the safety or integrity of the projected use) cease the installation and either obtain the advice of another qualified installer or contact FEC.
FEC
GLEN COVE, NY 11542
5 BREWSTER ST.
PHONE: (516) 967-9565 fecrack@ix.netcom.com
XXXX
HARDWARE: (4) 1/4" X 2 1/2" HEX HEAD LAG BOLT (8) 8-32 X 1/4" PHILLIPS PAN HEAD SCREW (2) 1/4-20 X 1/2" SCREWS (2) 1/4" LOCK WASHER
P/N 23758 09-11-20
C10-5250
PAGE 1 OF 2
FEC
BRACKET
MODEL FEC-100WMK (BLACK) OR FEC-100WMW (WHITE) WALL MOUNT BRACKET KIT FOR USE WITH PANASONIC AWUE-100 CAMERA
"INSTALLATION CAMERA WITH REAR CAMERA COVER"
HEIGHT 6.41 WIDTH 7.46 DEPTH 11.04 WITH EXTENSION
STEP 1
1
ATTACH BRACKET WITH (4) 8-32 X 1/4" SCREWS
EXTENSION PLATE
2
STEP 2
PANASONIC
1
MOUNT CAMERA TWIST LOCK PLATE TO EXTENSION PLATE THEN PLATE TO BRACKET WITH (8) 8-32 X 1/4" SCREWS
AS AN OPTION, THE WALL BRACKET MAY ALSO BE ATTACHED TO A 1 GANG, 2GANG OR 4" SQUARE EO BOX.
2
(DO NOT USE EO BOX AS SOLE SUPPORT. WALL MOUNT BRACKET SUFFICIENT SIZE SCREWS THROUGH THE .25" DIAMETER. MOUNTING HOLES.)
MOUNT BRACKET TO WALL USING APPROPRIATE HARDWARE THROUGH THE .25" MOUNTING HOLES. USE 1/4 x 2 1/2" LAG BOLTS FOR WOOD WALL STUDS. ROUTE CABLES THROUGH WIRE MANAGEMENT PORTS.
3
(MAKE CERTAIN THAT MOUNTING METHOD IS SECURE AND FOLLOWS ACCEPTED NORMS FOR THIS APPLICATION)
(IF BRACKET IS INVERTED MAKE SURE EXTENSION PLATE IS INSTALLED PRIOR TO ANCHORING TO WALL - SEE STEP 1)
MOUNT CAMERA TO TWIST-LOCK CAMERA BRACKET PER CAMERA INSTRUCTIONS
4
FINISH SECURING CAMERA TO MOUNTING PLATE WITH (1) SCREW SHIPPED WITH CAMERA
5
ATTACH DROP PREVENTION WIRE PER CAMERA INSTRUCTIONS, CONNECT CABLES.
6
INSTALL CABLE COVER TO CAMERA
HOLES FOR ATTACHING TO 1 & 2 GANG EO BOXES
AW-UE100 INS
TRUCTIONS
3
STEP 3 LAG BOLT
LOWER LAG BOLTS SECURE THRU EXTENSION PLATE & BRACKET
& EXTENSION PLATE
MUST BE SECURED WITH
PLACE CAMERA ON
STEP 4
4
MTG BRACKET & TWIST TO LOCK IN POSITION
SECUREPLATE
NOTE: THIS 1/4-20 X 1/2" SCREW ONLY USED TO SECURE CAMERA WHEN NO BRACKET IS USED
TO MOUNT WITH (4) 8-32 X 1/4" SCREWS
NOTE: REFER TO CAMERA INSTRUCTIONS WHERE DROP PREVENTION WIRE ATTACHES (SHIPS WITH CAMERA)
HOLES FOR ATTACHMENT TO 4" SQUARE EO BOX
5
STEP 5
INSTALL 3MM SCREW FLAT & LOCK WASHER TO SECURE CAMERA TO MOUNTING BRACKET (THIS HARDWARE SHIPS WITH CAMERA)
SAFETY NOTE:
- Before beginning the installation, it is very important to examine the unit for damage, defects and correct hardware.
- The Installation instructions must be read and entirely understood prior to install.
- It must be determined that the mounting surface is capable of supporting the mount and equipment.
- The Professional Installer must determine the proper way to attach the WALL BRACKET MODEL
- The installation of the mount and equipment is dependent on proper/secure attachment and is the responsibility of the installer.
- Make sure wall will support 4 times the combined weight of Equipment and Wall Mount.-
- This mount should be attached to wood studs only. Under no circumstances should this product be mounted to metal studs, unless an installation professional deems they have been adequately reinforced and will support 4 times the combined weight of Equipment and the Wall Mount.
- Please use only the bolts supplied with the unit or bolts of the correct size, making sure the hardware used is tightened properly for a secure installation..
- The WALL BRACKET MODEL is only intended to be used with the equipment listed on the install sheet. It is not meant to be used with any other equipment.
- If at anytime, a question arises regarding this installation (or regarding the safety or integrity of the projected use) cease the installation and either obtain the advice of another qualified installer or contact FEC.
XXXX
11.04
6
STEP 6
7.46
INSTALL COVER
HARDWARE: (4) 1/4" X 2 1/2" HEX HEAD LAG BOLT (
8) 8-32 X 1/4" PHILLIPS PAN HEAD SCREW (2) 1/4-20 X 1/2" SCREWS (2) 1/4" LOCK WASHER
FEC
5 Brewster St.-Unit 2
Glen Cove, NY 11542
PHONE: (516) 967-9565 fecrack@ix.netcom.com
C10-5250
P/N 23758 09-11-20
PAGE 2 OF 2
Loading...