FEC
BRACKET
MODEL FEC-100WMK (BLACK) OR FEC-100WMW (WHITE) WALL MOUNT
BRACKET KIT FOR USE WITH PANASONIC AWUE-100 CAMERA
"INSTALLATION CAMERA WITHOUT REAR CAMERA COVER"
HEIGHT 6.41
WIDTH 7.46
DEPTH 8.07
PANASONIC
MOUNT CAMERA TWIST LOCK PLATE TO BRACKET WITH (4) 8-32 X 1/4" SCREWS
1
AS AN OPTION, THE WALL BRACKET MAY ALSO BE ATTACHED TO A 1 GANG, 2GANG OR 4" SQUARE EO BOX.
(DO NOT USE EO BOX AS SOLE SUPPORT. WALL MOUNT BRACKET MUST BE SECURED WITH SUFFICIENT SIZE SCREWS
2
THROUGH THE .25" DIAMETER. MOUNTING HOLES.)
MOUNT BRACKET TO WALL USING APPROPRIATE HARDWARE THROUGH THE .25" MOUNTING HOLES.
USE 1/4 x 2 1/2" LAG BOLTS FOR WOOD WALL STUDS. ROUTE CABLES THROUGH WIRE MANAGEMENT PORTS.
3
(MAKE CERTAIN THAT MOUNTING METHOD IS SECURE AND FOLLOWS ACCEPTED NORMS FOR THIS APPLICATION)
MOUNT CAMERA TO TWIST-LOCK CAMERA BRACKET PER CAMERA INSTRUCTIONS
4
FINISH SECURING CAMERA TO MOUNTING PLATE WITH (1) SCREW SHIPPED WITH CAMERA
5
ATTACH DROP PREVENTION WIRE PER CAMERA INSTRUCTIONS, CONNECT CABLES.
AW-UE100 INS
TRUCTIONS
1
STEP 1
ATTACH
BRACKET
WITH (4)
8-32 X 1/4"
SCREWS
NOTE: THIS 1/4-20 X 1/2"
SCREW ONLY USED TO
SECURE CAMERA WHEN
NO BRACKET IS USED
2
STEP 2
HOLE SET FOR
ATTACHING
TO 1 & 2
GANG EO BOXES
HOLE SET FOR
ATTACHMENT
TO 4" SQUARE
EO BOX
STEP 3
3
LAG BOLT
4
STEP 4
PLACE CAMERA ON
MTG BRACKET &
TWIST TO LOCK
IN POSITION
9.17
5
STEP 5
NOTE: REFER TO
CAMERA
INSTRUCTIONS
WHERE DROP
PREVENTION
WIRE ATTACHES
(SHIPS WITH
CAMERA)
INSTALL 3MM SCREW
FLAT & LOCK WASHER
TO SECURE CAMERA
TO MOUNTING
BRACKET
(THIS HARDWARE
SHIPS WITH CAMERA)
SAFETY NOTE:
- Before beginning the installation, it is very important to examine the unit for damage, defects and correct hardware.
- The Installation instructions must be read and entirely understood prior to install.
- It must be determined that the mounting surface is capable of supporting the mount and equipment.
- The Professional Installer must determine the proper way to attach the WALL BRACKET MODEL
- The installation of the mount and equipment is dependent on proper/secure attachment and is the responsibility of the installer.
- Make sure wall will support 4 times the combined weight of Equipment and Wall Mount.-
- This mount should be attached to wood studs only. Under no circumstances should this product be mounted to metal studs, unless an installation professional
deems they have been adequately reinforced and will support 4 times the combined weight of Equipment and the Wall Mount.
- Please use only the bolts supplied with the unit or bolts of the correct size, making sure the hardware used is tightened properly for a secure installation..
- The WALL BRACKET MODEL is only intended to be used with the equipment listed on the install sheet. It is not meant to be used with any other equipment.
- If at anytime, a question arises regarding this installation (or regarding the safety or integrity of the projected use) cease the installation
and either obtain the advice of another qualified installer or contact FEC.
FEC
GLEN COVE, NY 11542
5 BREWSTER ST.
PHONE: (516) 967-9565
fecrack@ix.netcom.com
XXXX
HARDWARE:
(4) 1/4" X 2 1/2" HEX HEAD LAG BOLT
(8) 8-32 X 1/4" PHILLIPS PAN HEAD SCREW
(2) 1/4-20 X 1/2" SCREWS
(2) 1/4" LOCK WASHER
P/N 23758
09-11-20
C10-5250
PAGE 1 OF 2
FEC
BRACKET
MODEL FEC-100WMK (BLACK) OR FEC-100WMW (WHITE) WALL MOUNT
BRACKET KIT FOR USE WITH PANASONIC AWUE-100 CAMERA
"INSTALLATION CAMERA WITH REAR CAMERA COVER"
HEIGHT 6.41
WIDTH 7.46
DEPTH 11.04 WITH EXTENSION
STEP 1
1
ATTACH
BRACKET
WITH (4)
8-32 X 1/4"
SCREWS
EXTENSION
PLATE
2
STEP 2
PANASONIC
1
MOUNT CAMERA TWIST LOCK PLATE TO EXTENSION PLATE THEN PLATE TO BRACKET WITH (8) 8-32 X 1/4" SCREWS
AS AN OPTION, THE WALL BRACKET MAY ALSO BE ATTACHED TO A 1 GANG, 2GANG OR 4" SQUARE EO BOX.
2
(DO NOT USE EO BOX AS SOLE SUPPORT. WALL MOUNT BRACKET
SUFFICIENT SIZE SCREWS THROUGH THE .25" DIAMETER. MOUNTING HOLES.)
MOUNT BRACKET TO WALL USING APPROPRIATE HARDWARE THROUGH THE .25" MOUNTING HOLES.
USE 1/4 x 2 1/2" LAG BOLTS FOR WOOD WALL STUDS. ROUTE CABLES THROUGH WIRE MANAGEMENT PORTS.
3
(MAKE CERTAIN THAT MOUNTING METHOD IS SECURE AND FOLLOWS ACCEPTED NORMS FOR THIS APPLICATION)
(IF BRACKET IS INVERTED MAKE SURE EXTENSION PLATE IS INSTALLED PRIOR TO ANCHORING TO WALL - SEE STEP 1)
MOUNT CAMERA TO TWIST-LOCK CAMERA BRACKET PER CAMERA INSTRUCTIONS
4
FINISH SECURING CAMERA TO MOUNTING PLATE WITH (1) SCREW SHIPPED WITH CAMERA
5
ATTACH DROP PREVENTION WIRE PER CAMERA INSTRUCTIONS, CONNECT CABLES.
6
INSTALL CABLE COVER TO CAMERA
HOLES FOR ATTACHING
TO 1 & 2 GANG EO BOXES
AW-UE100 INS
TRUCTIONS
3
STEP 3
LAG BOLT
LOWER LAG BOLTS
SECURE THRU
EXTENSION PLATE
& BRACKET
& EXTENSION PLATE
MUST BE SECURED WITH
PLACE CAMERA ON
STEP 4
4
MTG BRACKET &
TWIST TO LOCK
IN POSITION
SECUREPLATE
NOTE: THIS 1/4-20 X 1/2"
SCREW ONLY USED TO
SECURE CAMERA WHEN
NO BRACKET IS USED
TO MOUNT
WITH (4)
8-32 X 1/4"
SCREWS
NOTE: REFER TO
CAMERA
INSTRUCTIONS
WHERE DROP
PREVENTION
WIRE ATTACHES
(SHIPS WITH
CAMERA)
HOLES FOR
ATTACHMENT
TO 4" SQUARE
EO BOX
5
STEP 5
INSTALL 3MM SCREW
FLAT & LOCK WASHER
TO SECURE CAMERA
TO MOUNTING
BRACKET
(THIS HARDWARE
SHIPS WITH CAMERA)
SAFETY NOTE:
- Before beginning the installation, it is very important to examine the unit for damage, defects and correct hardware.
- The Installation instructions must be read and entirely understood prior to install.
- It must be determined that the mounting surface is capable of supporting the mount and equipment.
- The Professional Installer must determine the proper way to attach the WALL BRACKET MODEL
- The installation of the mount and equipment is dependent on proper/secure attachment and is the responsibility of the installer.
- Make sure wall will support 4 times the combined weight of Equipment and Wall Mount.-
- This mount should be attached to wood studs only. Under no circumstances should this product be mounted to metal studs, unless an installation professional
deems they have been adequately reinforced and will support 4 times the combined weight of Equipment and the Wall Mount.
- Please use only the bolts supplied with the unit or bolts of the correct size, making sure the hardware used is tightened properly for a secure installation..
- The WALL BRACKET MODEL is only intended to be used with the equipment listed on the install sheet. It is not meant to be used with any other equipment.
- If at anytime, a question arises regarding this installation (or regarding the safety or integrity of the projected use) cease the installation
and either obtain the advice of another qualified installer or contact FEC.
XXXX
11.04
6
STEP 6
7.46
INSTALL
COVER
HARDWARE:
(4) 1/4" X 2 1/2" HEX HEAD LAG BOLT
(
8) 8-32 X 1/4" PHILLIPS PAN HEAD SCREW
(2) 1/4-20 X 1/2" SCREWS
(2) 1/4" LOCK WASHER
FEC
5 Brewster St.-Unit 2
Glen Cove, NY 11542
PHONE: (516) 967-9565
fecrack@ix.netcom.com
C10-5250
P/N 23758
09-11-20