When using an electrical appliance, basic precautions should always be followed, including the following.
READ ALL INSTRUCTIONS
BEFORE USING THIS VACUUM CLEANER
WARNING - To reduce the risk of fire, electric shock or injury:
1. Do not leave the vacuum cleaner when plugged in. Unplug it from the outlet when not in use and before servicing.
2. Do not use outdoors or on wet surfaces.
3. Do not allow vacuum cleaner to be used as a toy. Close attention is necessary when used by or near children or infirmed persons.
4. Use only as described in this manual. Use only the manufacturer's
recommended attachments.
5. Do not use with a damaged cord or plug. If the vacuum cleaner is not working
as it should, or if it has been dropped, damaged, left outdoors or dropped into water, return to FANTOM at 94 Main Mill Street, Door 16, Plattsburgh, NY 12901.
6. Do not pull or carry by the cord, use the cord as a handle, close a door on the
cord, or pull the cord around sharp edges or corners. Do not run the vacuum cleaner over the cord. Keep the cord away from heated surfaces.
7. Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
8. Do not handle the plug or the vacuum cleaner with wet hands.
9. Do not put any objects into the openings. Do not use with any opening
blocked: keep free of dust, lint, hair and anything that may reduce air flow.
10. Keep hair, loose clothing, fingers and all the parts of your body away from
openings and moving parts.
11. Do not pick up anything that is burning or smoking, such as cigarettes,
matches or hot ashes.
12. Do not use without dust compartment and filters in place.
13. Turn off all controls before unplugging.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up flammable or combustible liquids such as gasoline, or
use in areas where they may be present.
111
Rev. 06/05A
16. Do not touch the agitator while it is spinning.
17. Do not place any heavy items on top of the vacuum cleaner.
18. Do not step on the hose or pull it too strongly.
19. Do not pick up items such as pieces of waste paper or cloth which looks as
though they may cause the hose to become blocked.
20. Do not clean or store the vacuum cleaner in places where there are high
temperatures.
21. Store the vacuum cleaner away from excessive humidity.
22. When carrying the vacuum cleaner, hold it by the carrying handle.
23. Before servicing the vacuum cleaner, allow all internal metal parts to cool first.
24. Always place foot on handle release when adjusting the handle position
of the vacuum cleaner.
25. If the supply cord of this appliance is damaged, it must only be replaced by
FANTOM, because special purpose tools are required.
26. Connect to a properly grounded outlet only. See Grounding Instructions.
SAVE THESE INSTRUCTIONS
This vacuum is intended for household or commercial use.
Note to user concerning attachment plug:
Grounding Instructions
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING- Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit and has a grounding attachment plug that looks like the plug illustrated below. Make sure that the appliance is connected to an outlet having the same configuration as the plug.
Grounded
Outlet
Grounding
Pin
2
NAMES OF EACH PART
Handle
Release Button C
Carrying Handle
Duster Knob
Filter Cover
FRONT
Suction Hose A
Release Button A
Release Button B
ON/OFF Switch
Dust Compartment
Plug shown in figure may differ from actual plug attached to unit for your area.
Suction Hose B
Power Cord Plug
Cord Storage
Hooks
Hose Holder
REAR
Power Cord
Duster
Crevice Tool
Wand
Upholstery Tool & Dusting Brush
Height Adjustment Lever
Handle Release Lever
Headlight
Set the ON/OFF switch to " ON " to light the headlight.
Holder Mount
Cleaning Utensil
Rug/Floor (Tools) SELECTOR
WARNING:
Operate vacuum cleaner only at the voltage specified on name plate.
3
PREPARATIONS BEFORE USE
Caution: Do not connect the power cord plug to the wall outlet until assembly
is completed.
Attaching the handle
Set the vacuum cleaner
1
to the upright position.
lnsert the handle
2
as shown in the illustration.
Handle
Attaching the suction hose A & attachments
Wand
Crevice Tool
Suction Hose A
Suction Inlet
Hose Cuff
Upholstery Tool & Dusting Brush
Duster
4
PREPARATIONS BEFORE USE
WINDING THE POWER CORD
Wind the power cord around
1
the cord storage hooks.
Secure the power cord plug on the power cord.
Cord Storage Hooks
RELEASING THE POWER CORD
Rotate the upper cord
1
storage hook downward.
Upper Cord Storage Hook
Return the hook to the
2
upright position before attempting to rewind the power cord.
THERMAL SAFETY DEVICE IN MAIN BODY
To protect your vacuum cleaner motor from overheating, a thermal safety device has been built in. If your vacuum cleaner hose or air intake clogs up with dust or dirt, or if your dust bag becomes full and you continue to run the machine, the vacuum will shut off automatically to prevent the motor from overheating. If this happens, turn off slide switch and disconnect your vacuum from power outlet, remove the material clogging the machine and let your vacuum cool down for approximately 45 minutes. You can then restart your vacuum cleaner and use it again.
5
USING THE VACUUM CLEANER
ON/OFF SWITCH
Start or stop vacuum cleaner by pushing on the switch.
OFF ON
ADJUSTING THE HANDLE
The handle of this vacuum cleaner can be set to one of three positions -Upright, Normal, Parallel. Place your foot on handle release lever as shown and pull back on the handle until it releases from its upright position.
ON/OFF Switch
Upright position
The handle is normally locked in this position for storage or when using the attachments. Push the handle forward
until it locks.
Handle Release Lever
Normal position
This position is used for normal cleaning.
Handle Release Lever
Parallel position
This position is used for cleaning under furniture.
6
USING THE VACUUM CLEANER
HEIGHT ADJUSTMENT LEVER
Caution:
Before using the height adj­ustment lever,please make sure the nozzle head is tilted
Height Adjustment Lever
The nozzle head can be adjusted to four different height settings.
backward from the floor.
Nozzle Head
LOW
Carpet
HIGH
Bare Floor/Tools
Set the height adjustment to the appropriate carpet length.
TURN OFF BRUSH ROLL WHEN USING TOOLS.
RUG/FLOOR (TOOLS)SELECTOR
The RUG/FLOOR(TOOLS)selector should only be
adjusted while the vacuum cleaner is turned on
and in the upright position.
When cleaning a rug or carpet,first turn the
1
ON/OFF switch to the ON position,and then
set the RUG/FLOOR(TOOLS)selector to the
RUG position.
Rug/Floor (Tools) SELECTOR
When cleaning a bare floor or when using
2
one of the attachments,set the RUG/FLOOR
(TOOLS)selector to the FLOOR position.
Caution: Do not change the setting of the RUG/FLOOR(TOOLS)selector while the vacuum
cleaner is turned off.
EDGE CLEANING
This vacuum cleaner is equipped with an "edge cleaning" function for cleaning carpet edges near baseboards and stationary furniture.
7
USING THE ATTACHMENTS
Caution: When using one of the attachments during cleaning,set the vacuum
cleaner to the upright position.
Remove the attachments from the
1
vacuum cleaner.
Wand
Crevice Tool
Press the release button C to
2
disconnect the handle from the vacuum cleaner.
Caution:
When removing the attachments, pull them in the directions shown in the illustration.Pulling them in the wrong direction or pulling them forcefully may cause damage to the attachment clamp.
Attach the attachments on the handle or the suction hose B.
3
Attach the attachments as shown below.
Handle
Suction Hose A
Attachment Clamp
Wand
Crevice Tool
Duster
Upholstery Tool
Duster
Release Button C
Dusting Brush
Suction Hose B
Caution:
Hook the hose holder onto the holder mount.
Caution:
Before using the attachments, please make sure the hose is hooked on the holder mount.
Before using the suction hose B, please make sure the handle is reattached on the body.
Upholstery tool & Dusting brush
To detach the dusting brush from the upholstery tool: Press the tabs on the brush downward to remove it.
To reattach the dusting brush to the upholstery tool: Insert the front of the upholstery tool under the hook on the front of the dusting brush. Press down on the back of the upholstery tool to snap it into place under the dusting brush tabs.
When you have finished using the attachments,replace them in their original positions as shown on page 4.
Groove
Hose Holder
Holder Mount
Tabs
8
USING THE ATTACHMENTS
Hose Attachment
Line up notches push hose in till it clicks.
Suction Hose A
Suction Inlet
Hose Cuff
Handle
9
EMPTYING THE DUST COMPARTMENT
Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect the
power cord from the wall outlet before cleaning.
Empty the dust compartment when contents reach the MAX mark.
1
MAX mark
Press the release lever to open the
3
trapdoor.
Trapdoor
Release Lever
Press the release button A meanwhile
2
press the release button B to remove the dust compartment.
Release Button A
Release Button B
3
Turn the duster handle several times in the
4
direction shown to empty the dust compartment.
Duster Handle
Reattaching the Dust Compartment
Close the trapdoor and insert the projection on the
1
1
dust compartment into the groove on the main body.
Projection
Groove
10
Push the dust compartment into
2
2
the main body as shown to reattach.
CLEANING THE FILTERS
Remove the dust compartment.(refer to page 11)
1
Set the dust compartment to the parallel
2
position.Open the trapdoor,then push the release button E and pull out the main filter.
The main filter and prefilter will be removed at the same time.
Caution: Do not push the release button E at the upright position. As this may drop or damage the main filter and prefilter.
Clean the main filter and prefilter with a soft-bristled brush (not included) and
3
rinse with cold water. Allow both items to dry completely for 24 hours.
Caution:
Do not use a hard-bristled brush to clean filters. This may result in damage to the filters. Do not attempt to dry with a hair dryer or by placing in a clothes dryer.Hot air may cause the filters to warp.
Release Button E
3
Cleaning Utensil
To maintain optimum suction power, the dust filter fins should be kept clean of dirt.
Clean the filter fins free of dirt with the forked end of cleaning utensil as shown.
Cleaning Utensil
Reattaching the filters
Insert the main filter into the
1
prefilter as shown.
Main Filter
Prefilter
Hold onto the main filter and insert into
2
the dust compartment.
Align the ribs of the main filter to match the shape of the opening in the dust compartment and press firmly to insert.
Dust Compartment
Ribs
Hole
Close the trapdoor.
3
NOTE: We recommend replacing the main filter every three (3) to six (6) months, depending
on the amount of use
11
CLEARING BLOCKAGES AND CLEANING THE AGITATOR ASSEMBLY
Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect
the power cord from the wall outlet before clearing any blockages in the suction hose and cleaning the agitator assembly.
Cleaning blockages
Cleaning blockages in the suction hose A, B
Set the vacuum cleaner to the upright position.
1
Suction Hose A
Remove the hose cuff from the suction inlet and
2
then remove any blockages from the hose.
Reattach the hose cuff to the suction inlet,and
3
then operate the vacuum cleaner to check that the blockage has been properly cleared.If the hose is still blocked,the suction force will be weak.
Suction Inlet
Hose Cuff
Cleaning blockages in the nozzle head
Remove the bottom plate(refer to page 15)
1
Remove any blockages from the nozzle head.
Nozzle Head
Nozzle Pipe
2
Reattach the bottom plate to the nozzle head, and then operate the vacuum cleaner
3
to check that the blockage has been properly cleared. If the nozzle head is still blocked, the suction force will be weak.
Caution:
When the suction hose A, B or Nozzle head is blocked, the bypass valve will be opened automatically to protect the motor, resulting in the suction force being reduced. The bypass valve will be at its original position automatically after the blockage is removed.
Bypass Valve (Inside)
Cleaning the agitator assembly
When threads get caught in the agitator assembly, clean the assembly.
Remove the bottom plate(refer to page 15)
Remove threads caught in the assembly by cutting them with scissors.
Scissors Threads
12
REPLACEMENT INSTRUCTIONS
Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the
power cord from the wall outlet before replacing any of the parts below.
REPLACING THE HEADLIGHT LAMP
Set the vacuum cleaner to the parallel position.
1
Loosen the screws to remove the lens.
2
When removing the headlight lamp, be careful
3
not to pull on the headlight lamp wiring.
Screw
Lens
Remove the lamp by pushing it gently in
4
the direction of the arrow and then turning it counterclockwise.
Push a new lamp gently into the socket and
5
turn it clockwise to tighten it . Use a standard bayonet base appliance lamp rated at 120V and 15W (LAMP MAX.15W).
Caution: Be careful not to clamp the
headlight lamp wiring.
Reattach the lensand fasten the screws.
6
2
1
Headlight Lamp
2
1
Socket
Socket
13
REPLACEMENT INSTRUCTIONS
Caution: Be sure to turn the ON/OFF switch to the"OFF" position and disconnect the
power cord from the wall outlet before replacing any of the parts below.
REPLACING THE FLAT BELT
Remove the bottom plate.
1
(refer to page 15)
Lift out the agitator assembly, and then remove the flat belt from the motor shaft and
2
3
the agitator pulley.
Motor Shaft
Flat Belt
Place a new flat belt onto the motor shaft and pulley.
Motor Shaft
Flat Belt
Flat Belt
Pulley
Place the agitator assembly into the grooves in the nozzle head, making sure that the new
4
flat belt slides securely into the guide.
Bearing Holder
Groove
Nozzle Head
Reattach the bottom plate
5
(refer to page 15)
Caution:
Install the flat belt so that it has no twists in it, and so that all components turn smoothly.
14
REPLACEMENT INSTRUCTIONS
REMOVING THE BOTTOM PLATE
Set the vacuum cleaner to the
1
parallel position and turn it over.
Loosen
Using a Philips screwdriver, loosen
2
the screw on the bottom plate and
slide the latch in the direction of the arrow.
Lift the bottom plate off.
3
Latch
Mounting screw
REATTACHING THE BOTTOM PLATE
Screw
Insert the projection on the bottom plate
1
into the groove on the nozzle housing
and set the bottom plate in place.
Bottom Plate
Groove
Turn the vacuum over
3
and place in the upright position.
Projection
Re-tighten the screw using a Philips
2
screwdriver and slide the latch in the
direction indicated by the arrow.
Tighten
Screw
Latch
15
REPLACEMENT INSTRUCTIONS
REPLACING THE FILTER
Under normal usage, the HEPA Filter will require replacement once every three (3) months, however, vacuuming large amounts of extremely fine dust, powder or similar material over a long period of time may decrease airflow performance through the filter. If this occurs, it may become necessary to replace the HEPA Filter more often. Only use genuine FANTOM replacement filters.
Press in the locking tabs at points and pull the filter cover away fromthe
1
vacuum cleaner.
Remove the HEPAfilter.
2
Caution:
Do not attempt to wash the HEPA filter.
Always replace the old filter with a new one.
1
HEPA Filter
Filter Cover
11
11
22
Insert a new HEPA filter with the seal
3
to the inside of the vacuum cleaner. Reattach the filter cover.
Caution:
Be sure that seal on the HEPA filter is inserted towards the inside of the vacuum cleaner.
The filter cover should be correctly oriented when it is reattached. Do not reattach it upside down.
Seal
CLEANING THE SUB-FILTER
Clean the sub-filter when it becomes dirty.
Remove the dust compartment (refer to page 10).
1
Remove the air inlet cover.
Remove the sub-filter from the vacuum cleaner.
2
Gently clean the sub-filter with water.
3
Make sure that it is completely dry and then re-install it into the vacuum cleaner.
4
Replace the air inlet cover and the dust compartment.
Caution: Do not wash the sub-filter in a washing machine, and do not use any other equipment such as a hair dryer to dry it. Always allow 24 hours for drying. Do not operate the vacuum without the sub-filter. Be sure the sub-filter is dry and properly installed. Failure to do so could result in electrical shock, personal injury, or motor failure. Note: We recommend replacing the sub-filter every three (3) to six (6) months, depending on usage.
22
Air Inlet Cover
11
Sub-Filter
16
TROUBLESHOOTING
If there is a problem with the vacuum cleaner, carry out the following checks to find the cause. If the problem still persists after the checks have been made, do not use the vacuum cleaner to prevent the possibility of an accident occurring. Turn the ON/OFF switch to the "OFF" position, disconnect the power cord from the wall outlet, and contact FANTOM Customer Service at 1-800-275-9251.
Or visit our website at www.fantom.com
Problem Cause R emedy
The motor does not operate when the ON/OFF switch is set to the "ON" position.
The power cord plug is not securely inserted into the wall outlet.
Insert the power cord plug securely into the wall outlet.
Suction force is weak.
The agitator does not operate.
TO ORDER REPLACEMENT FILTERS CALL 1-800-275-9251
The dust compartment is full.
The suction hose is blocked.
The nozzle head is blocked.
The filters are dirty.
The nozzle air inlet pipe is blocked.
The bypass vavle is opened.
The flat belt is worn or broken.
Empty the dust compartment. (refer to page )
10
Remove the blockage. (refer to page 12)
Remove the blockage. (refer to page 12)
Clean the filters. (refer to page 11)
(refer to page 16) Remove the blockage.
(refer to page 12)
Remove the blockage. (refer to page 12)
Replace the flat belt. (refer to page 14)
9BF-D-P111-01600 0506-
E
17
THREE (3) YEAR LIMITED WARRANTY
FANTOM
warrants this product to be free from defects in material and workmanship for a period of three (3) years from the date of the original purchase, when utilized for normal commercial or household use, subject to the following conditions, exclusions and exceptions.
If your appliance fails to operate properly while in use under norma l household or commercial conditions within the warranty period, return the complete appliance and accessories, freight prepaid to
In US:
If the appliance is found by charge. Proof of purchase date and $21.95 to cover the cost of return shipping and handling must be included. *
Non-durable parts including, without limitation, dust cup filters, filters, belts, brushes and electrical parts which normally require replacement are specifically excluded from warranty.
The liability of warranty does not cover normal wear of parts and does not apply to any unit that has been tampered with or used for commercial purposes. This limited warranty does not cover damage caused by misuse, abuse, negligent handling or damage due to faulty packaging or mishandling in transit. This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs, service or alterations to the product or any of its parts, which have been performed by a repair person not authorized by
This warranty is extended to the original purchaser of the unit and excludes all other legal and/or conventional warranties. The responsibility of the limited whatsoever. Some states do not permit the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
*Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of purchase date and to attach tag to item before packing with your name, c omplete address and phone number with a note giving purchase information, model number and what you believe is the problem with item. We recommend you insure the package (as damage in shipping is not covered by your warranty). Mark the outside of your package ATTENTION CUSTOMER SERVICE .
FANTOM, 94 Main Mill Street, Door 16, Plattsburgh, N.Y. 12901
FANTOM
FANTOM
warranty.
FANTOM
is limited solely to the cost of the repair or replacement of the unit at our option. This
if any, is limited to the specific obligations expressly assumed by it under the terms of
In no event is
,,
to be defective in material or workmanship,
FANTOM.
FANTOM
liable for incidental or consequential damages of any nature
FANTOM
will repair or replace it free of
,,
OWNERSHIP REGISTRATION CARD
Please fill out and mail the product registration card within ten (10) days of purchase. The registration will enable us
to contact you in the unlikely event of a product safety notification. By returning this card you acknowledge to have read
and understood the instructions for use, and warnings set forth in the accompanying instructions.
RETURN TO FANTOM , 94 Main Mill Street, Door 16 , Plattsburgh , N.Y . 12901
Model: FM766HO - FM766HG - FM766HP
Appliance model
Date purchased
,
Owner s name
Address
Name of store
City State
Zip Code
Printed in China
Loading...