Fagor AD-15, AD- 21D, AD- 15D, AD-21, AD- 21B Technical Manual

...
Page 1 of 22
10/11/2009
TECHNICAL MANUAL
DISH WASHER
“ADVANCE”
Page 2 of 22
10/11/2009
PLATFORM
The platform used for controlling the low range, ADVANCE dishwasher (front loading, top loading
and glasswasher) is shown below.
ADVANCE
Serigraphy
Main control card
Temperature Card
Card Assembly
Page 3 of 22
10/11/2009
As can be seen from the picture, the platform has 2 cards, the main controller card and the auxiliary
temperature card, in addition to a membrane keyboard with 4 buttons and 5 LEDs permitting
interaction with the appliance.
TEMPERATURE CARD
The temperature card is powered through the control card but does not have any communication
with this card. This card only displays the tank and boiler temperatures, making use of 2 external
thermostats linked to the card.
MAIN CONTROL CARD
The control card has 4 inputs and 5 outputs, in addition to 4 dip-switches for configuring the
appliance:
Inputs:
TT / PC: Thermostat indicating whether the established tank temperature has been reached.
On the other hand, for a Clinic appliance, that is an appliance with break tank, this input
indicates the status of the boiler pressure switch
PT Input displaying the status of the tank pressure switch
TC: Displays the status of the boiler thermostat (CAUTION! The status of this input
signifies the opposite to that of the TT input)
IP: Input indicating the status of the door
Outputs:
V: Water inlet solenoid valve
MBL: Wash pump
Vreg: Regeneration solenoid valve. In a Clinic appliance, this valve is used to fill the boiler
BD: Drainage pump
RG: Main relay which disables the remaining outputs if not active
Page 4 of 22
10/11/2009
The configuration of the DIP-Switches is as follows:
o DIP1: Door
o If DIP1=0
Glass washer and front loading. To begin a new wash cycle, select the
required programme, the appliance is on stand-by meanwhile
o If DIP1=1
Top loading: To start a new wash cycle, just open and close the door, and
the last used programme is run
o DIP2: Regeneration
o If DIP2=0
The appliance does not have descaler
o If DIP2=1
The appliance has descaler Therefore, if B2 is pressed for 3 seconds, the
descaler cycle is activated
o DIP3: Time
o If DIP1=0& DIP3=0
P1=90 / P2=120 / P3=180
o If DIP1=0& DIP3=1
P1=60 / P2=90 / P3=180
o If DIP1=1& DIP3=0
P1=90 / P2=120 / P3=180
o If DIP1=1& DIP3=1
P1=55 / P2=80 / P3=120-∞
o DIP4: Clinic Line with break tank
o If DIP4=0: This is not a clinic line appliance o If DIP4=1
Vreg (The output Vreg is used as a boiler filler valve) For the thermostop, in addition to TC, TT should also be considered (PC in
this case). Do not end wash until TC=0 and TT=0
Page 5 of 22
10/11/2009
FAGOR ELECTRONIC ADVANCE MODEL DIP1 DIP2 DIP3 DIP4 CYCLE TIMES (s)
OTHER GLASSWASHER MODELS OFF OFF OFF OFF AD-15 D , AD-21 D OFF ON OFF OFF
P1=90 / P2= 120 / P3=180
OTHER GLASSWASHER MODELS A.F. OFF OFF ON OFF AD-48 D, AD-64 D OFF ON ON OFF AD-48 HY, AD-64 HY OFF OFF ON ON
P1=60 / P2= 90 / P3=180
OTHER GLASSWASHER MODELS TOP LOADING AD-90…. ON OFF OFF OFF
P1=75 / P2= 120 / P3=180
OTHER GLASSWASHER MODELS TOP LOADING AD-120... ON OFF ON OFF
AD-120 HY ON OFF ON ON
P1=55 / P2= 80 / P3=120 -
DIP1 = ON, when the door is closed or the cover lowered, the dishwasher st arts. DIP1= OFF, when the door is closed or the cover lowered, the dishwasher conti nues washi ng ONLY IF THE CYCLES HAS NOT FINISHED.
DIP2 = ON, For models fitted with WATER SOFTENER, version “D”. DIP2 = OFF, For models with DRAINAGE PUMP, versions “B”.
DIP1 + DIP3 , with the different posible combinations, we programme the cycle times DIP4 = ON, For models “HY”
DIP4 = OFF, For models wich do NOT have Break Tank “HY”
CSI INSTALACIONES
Page 6 of 22
10/11/2009
DIPS
ON
OFF
CSI INSTALACIONES
Page 7 of 22
10/11/2009
INTERFACE
One of the possible serigraphic combinations (membrane keyboard) is shown below. This has been
designed to interact with the 5 RELAY card.
These are the components of the above combination:
B1 (ON/OFF button)
o Button for switching appliance on/off. The button should be pressed for 2 seconds
L1 (ON/OFF LED)
o LED indicating whether the appliance is ON or OFF. If the appliance is running, the LED is lit,
otherwise it is off
Note: Depending on the model, this button may have the auxiliary function of descaler or drainage
pump
B2 (Button P1)
o If this button is pressed once, the dishwasher will start to wash with programme 1, provided
the door is closed
o If the button is pressed for 3 seconds, this activates the function corresponding to the right
icon (Descaler or drainage pump, depending upon the DIP2 configuration)
o If DIP2=0: Drainage pump If the door is open (relief valve removed) the drainage
pump is activated for 2 minutes (As with the EDESA software)
o If DIP2=1: Descaler: The regeneration cycle is run, as shown in the above graph.
Loading...