Extron electronic HPA 1001-70V, HPA 502 User Manual

audio
HPA 502
HPA 1001-70V
Half Rack PoweR amPlifieRs
n 100 watts rms power output
n Professional grade amplifier design
less than 1 watt power consumption in standby
n Highly efficient Class D amplifier
design
n Patented CDRS
Suppression
n Convection cooled
n Plenum rated
n Compact 1U, half rack width
enclosure
n Auto-standby with fast power-up
n Remote volume and mute
control port
®
qualified amplifier –
- Class D Ripple
HPA 502
100 Watt 2 Channel Half Rack Power Amplifier
HPA 1001-70V
70 Volt 100 Watt Mono Half Rack Power Amplifier
The Extron HPA 502 and HPA 1001-70V are compact, highly efficient, ENERGY
STAR qualified audio power amplifiers that are professional grade and feature Class
D amplification with patented CDRS - Class D Ripple Suppression technology for
near-zero EMI emissions. These compact 1U, half rack width amplifiers are ideal for
installation in lecterns and equipment racks with limited space and ventilation.
n Hidden, detented rear panel
level controls
n Multiple protection circuits
n Remote standby port
www.extron.com
DESCRIPTION
FEATURES (Cont.)
The Extron HPA 502 and HPA 1001-70V are compact power amplifiers designed for installation in racks and lecterns. These ENERGY STAR qualified amplifiers feature a highly efficient Class D amplifier design with patented CDRS - Class D Ripple Suppression technology from Extron that nearly eliminates EMI emissions and interference with wireless A/V equipment. This high efficiency allows the amplifiers to be convection cooled without the need for fans and operate in environments with little or no ventilation. These professional grade amplifiers deliver more than 100 dB signal­to-noise ratio, unweighted and THD + Noise of less than 0.05%. With a compact, plenum-rated 1U, half rack width enclosure, the HPA 502 and HPA 1001-70V deliver ample power output for speaker systems in classrooms, meeting rooms, boardrooms, and commercial environments.
The HPA 502 and HPA 1001-70V are ENERGY STAR qualified amplifiers and energy efficient products to help meet green building requirements. They consume just 8 watts when idle and less than one watt in standby mode. The HPA 502 and
HPA 1001-70V enter into standby after one hour of inactivity, or when the standby port is triggered. Additionally, both amplifiers are plenum-rated, allowing for a concealed installation above a drop ceiling to prevent theft while providing convenient placement of A/V equipment.
HPA 502
The HPA 502 two channel amplifier delivers 50 watts rms per channel into 4 or 8 ohms for amplification of voice or program audio content to stereo program speakers, or two sets of distributed ceiling speakers in a dual zone application.
HPA 1001-70V
The HPA 1001-70V delivers 100 watts rms for 70 volt constant voltage speaker distribution systems for voice reinforcement and PA - public address applications.
The HPA 502 and HPA 1001-70V accept balanced and unbalanced input signals and include detented level controls located on the rear panel to prevent tampering. These controls allow for proper audio system gain structure, or setting individual levels for each zone. Remote control capability is available for volume adjustment and muting. Additionally, both amplifiers include multiple protection circuits that activate when an abnormal condition, such as excessive clipping or overheating, is detected.
FEATURES
n 50 watts rms per channel into 4 or 8 ohms - HPA 502 – The
HPA 502 provides greater power output for larger rooms than smaller amplifiers with lower power ratings.
n
100 watts rms output for 70 volt speaker systems - HPA 1001-70V –
The H
PA 1001-70V provides greater power output for larger rooms
than smaller amplifiers with lower power ratings.
n Professional grade amplifier design – The HPA 502 and
HPA 1001-70V deliver more than 100 dB signal-to-noise ratio, unweighted and THD + Noise of less than 0.05% for ultra-low noise performance.
n ENERGY STAR qualified amplifiers – The HPA 502 and
n Highly efficient Class D amplifier design – The HPA 502 and
n Patented CDRS - Class D Ripple Suppression – A patented,
n Convection cooled – The HPA 502 and HPA 1001-70V are
n Plenum rated when used with optional Flexible Conduit Adapter
n Compact 1U, half rack width metal enclosure – With the capability
n Auto-standby with fast power-up – The HPA 502 and
n Rear panel detented level controls – Provide attenuation of input
n Multiple protection circuits – Activate during excessive clipping,
n Remote standby port – Enables the HPA 502 and HPA 1001-70V
n Remote volume and mute control port – In basic installations
n Input summing - HPA 1001-70V – Actively sums incoming left and
n High pass filter - HPA 1001-70V – This switch selectable filter
n Screw-lock, 5 mm captive screw speaker connectors – Enables
n
n Internal international power supply
HPA 1001-70V are energy efficient products to help meet green building requirements for low power consumption and reduced operating costs.
HPA 1001-70V generate substantially less heat than conventional amplifier designs, making them ideal for installation in equipment racks and lecterns with very limited ventilation. They consume 8 watts when idle and less than 1 watt in standby mode.
exclusive technology from Extron that nearly eliminates the high frequency switching ripple and EMI emissions found in typical
Class D amplifiers. CDRS enables Extron power amplifiers to be situated near wireless A/V devices without RF interference.
convection cooled without the need for fans, ensuring quiet, reliable operation.
Kit, part # 70-228-02 – The HPA 502 and HPA 1001-70V meet UL 2043 for smoke and heat release for installation within a plenum airspace above a drop ceiling. Above-the-ceiling placement conceals the amplifier to prevent theft, and is convenient for installing equipment when space inside the room is limited.
to deliver full-sized amplifier power in half the size of many conventional amplifiers, the HPA 502 and HPA 1001-70V reduce rack space requirements for many installations.
HPA 1001-70V automatically enter into a standby mode after one hour of inactivity, dramatically reducing power consumption. They quickly return to full power status upon signal detection.
signals for setting proper audio system gain staging as well as two­zone applications. Their location on the rear panel prevents users from tampering with level adjustments.
thermal overload, or DC faults to prevent damage to the amplifier and speakers.
to be remotely powered down when not in use, reducing operating cost.
without third-party control systems, this port allows the HPA 502 and HPA 1001-70V to be remotely controlled using the optional Extron VCM 100 Series volume and mute or VC 50 volume controllers.
right channel signals for mono amplification.
rolls off frequencies below 80 Hz to prevent saturation of speaker transformers.
simple, secure connections with 22 to 14 AWG speaker cables.
Front and rear-mounted signal and protection indication LEDs – Provide convenient indication of amplifier operation from both sides of an equipment rack.
100-240V 1.3A, 50-60Hz
VOL/MUTE 10V
STANDBY
4/8 OHM 50W x 2
1
2
LISTED 17TT
AUDIO/VIDEO
APPARATUS
CLASS 2 WIRING
HPA 502
C US
LEVEL
1
1 2
1 2
LIMITER/
PROTECT
SIGNAL
2
INPUTS
OUTPUT
REMOTE
0 0
100-240V 1.3A, 50-60Hz
VOL/MUTE 10V
STANDBY
4/8 OHM 50W x 2
1
2
LISTED 17TT
AUDIO/VIDEO
APPARATUS
CLASS 2 WIRING
HPA 502
C US
LEVEL
1
1 2
1 2
LIMITER/
PROTECT
SIGNAL
2
INPUTS
OUTPUT
REMOTE
0 0
Extron HPA 502
Audio Power Amplier
Extron
Flexible Conduit Adapter Kit
The con duit ad apter plate re places the IEC pl ate
DESCRIPTION
SPECIFICATIONS
Plenum Rated
In many rooms, the space above the ceiling is often used as a return air plenum. To ensure safety from potentially harmful heat and smoke release in the event of a fire, A/V products installed in ceilings with a plenum airspace must comply with safety codes and be specifically rated for use in plenum environments. The HPA 502 and HPA 1001-70V power amplifiers are both UL 2043 rated to conform to heat and smoke release codes for plenum environments. Installing an amplifier above a drop ceiling offers flexibility for integrators wanting to conserve rack space and achieve a clean, streamlined installation free of visible cable runs. An amplifier situated above the ceiling is also concealed from view, which prevents the possibility of theft.
Flexible Conduit Adapter Kit
The HPA 502 and HPA 1001-70V feature a built-in power supply with a modular power connection. In a rack installation, these amplifiers would be powered from an AC receptacle. However, when the amplifier is to be permanently situated above a drop ceiling, the HPA 502 and HPA 1001-70V can be directly hard-wired for AC power when the optional Flexible Conduit Adapter Kit, part # 70-228-02, is used in place of a conventional power cord. With this kit, the wiring is encased in flexible conduit, which connects directly to the amplifier and a local junction box. This can simplify installation without the necessity to provide an AC receptacle above the drop ceiling. As with the HPA 502 and HPA 1001-70V, the Flexible Conduit Adapter Kit is plenum-rated and meets UL 2043 for smoke and heat release.
Audio
Voltage gain
HPA 502 / HPA 1001-70V ........................ 16x (24 dB) / 57x (35 dB)
Audio input
Number/signal type ............................... 2 stereo/mono, balanced/unbalanced
Connectors ............................................ (1) 3.5 mm captive screw connector, 5 pole
Impedance ............................................ >10k ohms unbalanced/balanced, DC coupled
Nominal level ......................................... +4 dBu (1.23 Vrms), balanced
Maximum level ...................................... +20 dBu (7.75 Vrms), balanced
Input sensitivity
HPA 502 ................................................. +4 dBu (1.23 Vrms)
HPA 1001-70V ........................................ +4 dBu (1.23 Vrms) if driven by one input
-2 dBu (0.615 Vrms) if both inputs are summed
Stereo channel separation (HPA 502) ...... >75 dB @ 1 kHz
CMRR .................................................... >75 dB @ 1 kHz
NOTE: 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu
Audio output
Number/signal type
HPA 502 ..............................................
HPA 1001-70V .....................................
Connectors
HPA 502 .............................................. (1) 5 mm screw lock captive screw connector,
HPA 1001-70V ..................................... (1) 5 mm screw lock captive screw connector,
Minimum load impedance
HPA 502 ..............................................
HPA 1001-70V .....................................
Amplifier type ......................................... Class D
Continuous power output with a full load and 1% THD at 1 kHz
HPA 502 .............................................. 50 watts (rms) per channel at 4 or 8 ohms
HPA 1001-70V .....................................
Frequency response ................................ 20 Hz to 20 kHz, ±1 dB
THD + Noise .......................................... <0.05% @ 1 kHz at full rated power, 8 ohms
S/N ......................................................
Damping factor (HPA 502 only) .............. >100 @ 8 ohms
High pass filter (HPA 1001-70V only) ...... 80 Hz, 12 dB per octave (switch selectable)
1 stereo, 4- or 8-ohm 1 mono 70 V
4 pole
2 pole
4 ohms 100 watts into a 70 V line
100 watts (rms)
(HPA 502) or 70 V (HPA 1001-70V)
>100 dB (unweighted)
Control/remote – Amplifier
Control port............................................ (1) 3.5 mm captive screw connector, 5 pole
Pin configurations
DC volume control (analog) ................ Pin 1 = 10 VDC, pin 2 = volume/mute (10k ohm
Standby power control (contact closure)
pot.), pin 3 = GND
.. Pin 4 = GND, pin 5 = standby
GenerAl
Power .................................................... 100 VAC to 240 VAC, 50/60 Hz, internal
Typical .................................................... 20 watts
Quiescent ............................................... 8 watts
Standby .................................................. <1 watt (triggered by contact closure or after
Cooling................................................... Convection, unvented, with internal heat sinks
Protection ............................................... Clip limiting, thermal, short circuit, DC output
Indication ............................................... Limiter/Protect LED indicates the onset of clip
Rack mount ............................................ Yes, with optional 1U rack shelf, part #60-190-01
Enclosure type ....................................... Metal
Enclosure dimensions ............................. 1.7" H x 8.7" W x 9.5" D (1U high, half rack wide)
Product weight ....................................... 2.5 lbs (1.1 kg)
Shipping weight .................................... 7 lbs (4 kg)
Listings ................................................... UL, CUL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release; meets UL 60950 and UL 6500 for safety.
Compliances ........................................... CE, FCC Class A, VCCI, AS/NZS, ICES,
MTBF ...................................................... 30,000 hours
Warranty ................................................ 3 years parts and labor
NOTE: All nominal levels are at ±10%.
Model Version Description Part Number
HPA 502 100 Watt Two Channel Power Amplifier ..................
HPA 1001-70V 70 Volt 100 Watt Mono Power Amplifier ................. 60-850-01
Optional Accessories
Flexible Conduit Adapter Kit For PS 123 .................................................... 70-228-02
RSB 129 1U 9.5" Deep Basic Rack Shelf ..................................................... 60-604-01
Specifications are subject to change without notice.
1 hour with no signal)
limiting, thermal cycling, short circuit, or DC output protection
(RSU 129) or #60-604-01 (RSB 129)
4.3 cm H x 22.1 cm W x 24.1 cm D
®
ENERGY STAR
qualified amplifier
60-849-01
APPLICATION DIAGRAMS
Extron Electronics, Europe
Beeldschermweg 6C, 3821 AH Amersfoort The Netherlands +800.3987.6673 +31.33.453.4040 FAX +31.33.453.4050
Extron Electronics, Asia
135 Joo Seng Rd. #04-01 PM Industrial Bldg. Singapore 368363 +65.6383.4400 FAX +65.6383.4664
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan +81.3.3511.7655 FAX +81.3.3511.7656
Extron Electronics, USA
1230 South Lewis Street Anaheim, CA 92805
800.633.9876 714.491.1500 FAX 714.491.1517
1
0
0
-
2
4
0
V
5
0
-
6
0
H
z
I
N
P
U
T
V
ID
V
ID
Y
C
Y
B
-
Y
R
-
Y
R
G
B
D
V
I
1
2
4
5
3
L
2
3
4
5
6
7
R
A
U
D
IO
IN
P
U
T
L
A
B
R
O
U
T
P
U
T
L
R
O
U
T
P
U
T
R
G
B
Y
,
B
-
Y
,
R
-
Y
8
7
R
G
B
6
LISTE
D
1T23 I.
T.
E.
C
U
S
1
VCR
Document
Camera
RS-232 Control
LCD Projector
Laptop
DVD Player
PC
Extron IN1508
Scaling Presentation Switcher
PC DVI Input
Extron HPA 502
Audio Power Amplier
1
0
0
-
2
4
0
V
1
.
3
A
,
5
0
-
6
0
H
z
V
O
L
/
M
U
T
E
1
0
V
S
T
A
N
D
B
Y
4
/8
O
H
M
5
0
W
x
2
1
2
L
I
S
TE
D
1
7
TT
A
U
D
I
O
/
V
I
D
EO
A
PP
A
R
AT
U
S
C
L
A
SS
2
WI
R
I
N
G
H
P
A
5
0
2
C
U
S
L
E
V
EL
1
1
2
1
2
L
I
M
IT
ER
/
PR
O
TE
C
T
SI
GN
A
L
2
IN
P
U
TS
O
U
TP
U
T
R
E
M
O
T
E
0
0
Extron SI 28
Surface-mount Speakers
100-240V 1.3A, 50-60Hz
VOL/MUTE 10V
STANDBY
4/8 OHM 50W x 2
1
2
LISTED 17TT
AUDIO/VIDEO
APPARATUS
CLASS 2 WIRING
HPA 502
C US
LEVEL
1
1 2
1 2
LIMITER/
PROTECT
SIGNAL
2
INPUTS
OUTPUT
REMOTE
0 0
HPA Series
AUDIO POWER AMPLIFIER
1 2
LIMITER/PROTECT
SIGNAL
HPA Series
AUDIO POWER AMPLIFIER
LIMITER/PROTECT
SIGNAL
100W
VOL/MUTE 10V
STANDBY
80 Hz
L(MONO)
R
LISTED 17TT
AUDIO/VIDEO
APPARATUS
C US
CLASS 2 WIRING
HPA 1001-70V
OUTPUT
70V
LEVEL HPF INPUTS
REMOTE
0
LIMITER/
PROTECT
SIGNAL
100-240V 1.3A, 50-60Hz
5
0
/
6
0
H
z
1
0
0
-
2
4
0
V
0
.
3
A
L
1
R
L
2
R
L
3
R
L
4
R
L
1
R
L
2
R
L
3
R
L
4
R
L
1
R
L
2
R
L
3
R
L
4
R
L
3
R
L
4
R
I N P U T S
O U T P U T S
C O N T R O L
I N P U T S
O U T P U T S
R
E
S
E
T
A
C
T
L
I
N
K
R
S
-
2
3
2
1
2
3
4
1
5
6
7
8
1
9
1
0
1
1
1
2
1
2
2
2
COMPUTER IN
COMPUTE
R OUT
VIDEO IN
S-VIDEO IN
OUT
OUT
COMPU
T
ER
VIDE
O
S-VIDE
O
VA
R
I
BLE
Projector
Plasma Monitor
VCR (4)
DVD (4)
PC (2)
Laptop (2)
Extron MPX 423
Media Presentation Matrix
Ex
tron
HPA 1001-70V
Audio
Power
Amplier
Extron SI 3CT LP
Full-Range Ceiling Speakers
TCP/IP
Network
VGA
S-video
Remote Monitoring and Control
Video
Video
VGA
S-video
1
00
W
VO
L
/M
U
T
E
10
V
ST
A
ND
B
Y
80 Hz
L
(M
O
N
O
)
R
L
IS
T
E
D
1
7
T
T
A
U
D
IO
/
V
I
D
E
O
A
P
P
A
R
A
T
U
S
C
U
S
C
L
A
S
S
2
W
IR
IN
G
HP
A
1001-70V
O
U
T
P
U
T
7
0
V
L
E
V
E
L
H
F
P
I
N
P
U
T
S
R
E
M
O
T
E
0
L
IM
IT
E
R
/
P
R
O
T
E
C
T
S
I
G
N
A
L
10
0
-
2
4
0
V
1
.
3
A
,
5
0
-
6
0
H
z
PANEL DRAWINGS
HPA 502 - Front
HPA 502 - Back
© 2007 Extron Electronics. All rights reserved. All trademarks mentioned are the property of their respective owners.
HPA 1001-70V - Front
HPA 1001-70V - Back
07-07 68-1423-01 REV. B
Loading...