EVCO EK356AJ7 User Manual

EK 356A
ovens
Version 1.00 of 16th March 2004
File ek356a_eng_v1.00.pdf
PT
EVERY CONTROL S.r.l.
Via Mezzaterra 6, 32036 Sedico Belluno ITALY
Phone 0039-0437-852468 • Fax 0039-0437-83648
info@evco.it • www.evco.it
1 PREPARATIONS
1.1 How to install the instrument
Panel mounting, panel cut out 67 x 138 mm (2.63 x 5.43 in),
with screw brackets (supplied by the builder).
Every Control S.r.l. • EK 356A • Sheet 1/2
ENGLISH
installation with screw brackets; moderate the clamping torque, in order not to damage
box and screw brackets.
2 OPERATION
2.1 How to turn the instrument ON/OFF
(2) (3)
for 2 s
(1)
for 2 s
.
• press
During the normal operation the instrument shows the top tem-
perature (in the display at the top), the floor temperature
(in the display in the middle) and the cooking timer length
(in the display at the bottom).
2.2 How to silence the buzzer
• press
2.3 How to turn the steam generator ON/OFF
• press
smart guide
2.4 Steam injection
To inject steam:
• press
The steam will be injected if the steam generator is turned ON,
for the time you have set with parameter tb1 or as long as you
release button
2.5 How to turn the extractor ON/OFF
• press
2.6 How to activate/deactivate function Economy
• press
During this function top and floor outputs will alternatively be
activated for 50 % of the time you have set with parameter c1.
2.7 How to turn the chamber light ON/OFF
• press
3 TIMER FOR DELAYED STARTING
3.1 How to set the timer for delayed starting
To modify the timer for delayed starting:
• be sure the instrument is turned OFF
• press
• press or within 4 s
• press
To activate the timer:
• be sure the instrument is turned OFF
• press
As soon as the time you have set with the procedure passes, the
device will automatically turn ON
(1) you can set the timer for delayed starting between 1 and 99 h
(2) the instrument stores the course of the time every 30 min
(3) the first time the instrument stores the course of the value (after a lack of power
supply) will take place after 15 min the power supply has recovered, in order to
ensure the course storing even if the lacks take place over and over again.
4 COOKING TIMER
4.1 How to set the cooking timer
To modify the cooking timer:
• be sure the instrument is turned ON
• press
• press or within 4 s
(4)
• press
To activate/deactivate the timer:
• be sure the instrument is turned ON
• press
for 2 s
As soon as the time you have set with the procedure passes, the
buzzer will be activated for the time you have set with param-
eter c4.
(4) you can set the cooking timer between 1 and 99 min.
5 WORKING SETPOINT
5.1 How to set the top setpoint
• press
• press or within 4 s
(5)
• press
(5) you can set the top setpoint between the limits you have set with parameters rA1
and rA2.
5.2 How to set the floor setpoint
• press
• press or within 4 s
(6)
• press
(6) you can set the top setpoint between the limits you have set with parameters rA1
and rA2.
6 CONFIGURATION PARAMETERS
6.1 How to set configuration parameters
Configuration parameters are arranged on two levels.
To gain access the first level:
• press
and for 4 s : the instrument
will show
To select a parameter:
• press
or
To modify the value of the parameter:
• press
and or
To gain access the second level:
• gain access the first level
• press
or to select
• press and or to select “ -19
• press
and for 4 s : the instrument
will show
To quit the procedure:
• press
and for 4 s or do not op-
erate for about 60 s.
7 SIGNALS
7.1 Signals
LED
LED top
if it is lit, the top output will be turned ON
LED floor
if it is lit, the floor output will be turned ON
LED steam generator
if it is lit, the steam generator will be turned ON
LED steam injector
if it is lit, the steam injection will be running
LED extractor
if it is lit, the extractor will be turned ON
LED economy
if it is lit, function Economy will be activated
LED chamber light
if it is lit, the chamber light will be lit
°C
LED Celsius degree
if it is lit, the unit of measure of the temperature showed by the instru-
ment will be Celsius degree
°F
LED Fahrenheit degree
if it is lit, the unit of measure of the temperature showed by the instru-
ment will be Fahrenheit degree
h
LED hour
if it is lit, the unit of measure of the time showed by the instrument will
be hour
MEANING
11 ELECTRICAL CONNECTION
11.1 Electrical connection
(10) provide the probe with a protection able to protect it against contacts with metal parts or use insulated probes.
AA4 1 7 --- 1 kind of temperature alarm (1 = it will never be activated, 2 = absolute lower temperature
alarm, 3 = absolute upper temperature alarm, 4 = lower temperature alarm relative to the
top setpoint, 5 = upper temperature alarm relative to the top setpoint,
6 = lower temperature alarm relative to the top setpoint with automatic calculation and
enabling, 7 = upper temperature alarm relative to the top setpoint with automatic calcula-
tion and enabling)
LABEL MIN. MAX. U.M. DEF. SECOND ALARM (it is related to the floor temperature)
Ab0 1 99 °C/°F
Ab1 -99 999 °C/°F
(7)
2 hysteresis (differential, it is relative to Ab1, it is important if Ab4 1)
(7)
0 second temperature alarm threshold (it is important if Ab4 1); look at Ab4 as well
Ab3 0 999 min 0 second temperature alarm exclusion time since you turn the instrument ON (it is important
if Ab4 1)
Ab4 1 7 --- 1 kind of temperature alarm (1 = it will never be activated, 2 = absolute lower temperature
alarm, 3 = absolute upper temperature alarm, 4 = lower temperature alarm relative to the
floor setpoint, 5 = upper temperature alarm relative to the floor setpoint,
6 = lower temperature alarm relative to the floor setpoint with automatic calculation and
enabling, 7 = upper temperature alarm relative to the floor setpoint with automatic calcula-
tion and enabling)
LABEL MIN. MAX. U.M. DEF. ECONOMY/COOKING TIMER
c1 1 999 s 80 cycle time to turn ON the top output and the floor output during function Economy
(9)
c4 -1 120 s 5 time the buzzer is activated at the end of the cooking timer (-1 = the buzzer has to be silenced
by hand)
LABEL MIN. MAX. U.M. DEF. RESERVED
L1 --- --- --- --- reserved
L2 --- --- --- --- reserved
L3 --- --- --- --- reserved
L4 --- --- --- --- reserved
(7) the unit of measure depends on parameter /8
(8) ds = 0.1 seconds
(9) during function Economy top and floor output will alternatively be activated for 50 % of the time you have set with parameter.
LED minute
min
if it is lit, the unit of measure of the time showed by the instrument will
be minute
LED timer
start
if it flashes, the count of the timer for delayed starting (or the count of
the cooking timer) will be running
LED ON STAND-BY
if it is lit, the instrument will be in the STAND-BY mode (turned OFF)
INDICAT.
the instrument has finished counting the cooking timer
8 ALARMS
8.1 Alarms
CODE
corrupted
memory
data
alarm
top probe
alarm
Every Control S.r.l. • EK 356A • Sheet 2/2
REASONS
there is a corruption of
the configuration data
in the memory of the
instrument
• the kind of top probe
you have connected
is not right
• the top probe plays
up
• the connection in-
strument-top probe
is wrong
• the top temperature
is outside the limits
allowed by the work-
ing range of the in-
strument
MEANING
REMEDIES
turn OFF the power
supply of the instru-
ment: unless the alarm
disappears, you will
have to change the in-
strument
• look at parameter /0
• test the integrity of
the probe
• test connection in-
strument-probe
• test the temperature
close to the probe
EFFECTS
• the access to the set-
ting procedures will
not be allowed
• all outputs will be
turned OFF
the top output will be
turned OFF
• the kind of floor
probe you have con-
floor
nected is not right
probe
• the floor probe plays
alarm
up
• the connection in-
strument-floor probe
is wrong
• the floor tempera-
ture is outside the
limits allowed by the
working range of
the instrument
there is a defect in the
cold joint of the instru-
cold joint
ment
alarm
the top temperature is
outside the limit you
first
have set with param-
tempera-
eter AA1
ture alarm
the floor temperature
is outside the limit you
second
have set with param-
tempera-
eter Ab1
ture alarm
The indications showed by the instrument flashes, except the indications “AL1“ and
AL2“ (they are alternated with the top or the floor temperature) and the buzzer utters
an intermittent beep.
• look at parameter
/0
• test the integrity of
the probe
• test connection in-
strument-probe
• test the temperature
close to the probe
turn OFF the power
supply of the instru-
ment: unless the alarm
disappears, you will
have to change the
instrument
test the temperature
close to the probe
(look at parameters
AA0, AA1 and AA4)
test the temperature
close to the probe
(look at parameters
Ab0, Ab1 and Ab4)
the floor output will
be turned OFF
• the top output will
be turned OFF
• the floor output will
be turned OFF
no effect
no effect
9 TECHNICAL DATA
9.1 Technical data
Box: self-extinguishing grey.
Size: 72 x 144 x 79 mm (2.83 x 5.66 x 3.11 in).
Installation: panel mounting, panel cut out 67 x 138 mm (2.63 x 5.43 in), with screw
brackets (supplied by the builder).
Frontal protection: IP 54.
Connections: extractable terminal blocks with pitch 7.5 mm (0.29 in) for cables up to
2.5 mm² (0.38 sq in, power supply and outputs) and with pitch 5 mm (0.19 in) for
cables up to 2.5 mm² (0.38 sq in, inputs).
Ambient temperature: from 0 to 55 °C (32 to 131 °F, 10 ... 90% of relative humidity
without condensate).
Power supply: 230 Vac, 50/60 Hz, 4 VA (standard) or 115 Vac, 50/60 Hz, 4 VA
(by request).
Alarm buzzer: included.
Measure inputs: 2 (top and floor probe) for “J” or “K” thermocouples.
Working range: from 0 to 700 °C (32 to 999 °F) for “J” thermocouple,
from 0 to 999 °C (32 to 999 °F) for “K” thermocouple.
Setpoint range: from 0 to 999 °C (0 to 999 °F).
Range of the timer for delayed starting: from 1 to 99 h.
Range of the cooking timer: from 1 to 99 min.
Resolution: 1 °F with unit of measure in Fahrenheit, 1 °C with unit of measure in
Celsius.
Display: two red LED 3-digit displays 13.2 mm (0.51 in) high, one red LED 2-digit
display 13.2 mm (0.51 in) high, output status indicators, indicators of the unit of meas-
ure of the temperature showed by the instrument.
Outputs: 6 relays: one 8 A @ 250 Vac relay for top heating group control (NO),
one 8 A @ 250 Vac relay for floor heating group control (NO), one 10 A @ 250 Vac relay
for steam generator control (NO), one 8 A @ 250 Vac relay for steam injection control
(NO), one 8 A @ 250 Vac relay for extractor control (NO), one 8 A @ 250 Vac relay for
chamber light control (NO); the maximum current allowed on terminal 21 and 26 is
10 A.
10 WORKING SETPOINT AND CONFIGURATION PARAMETERS
10.1 Working setpoint
LABEL MIN. MAX. U.M. DEF. WORKING SETPOINT
rA1 rA2 °C/°F
rA1 rA2 °C/°F
(7)
0 top setpoint
(7)
0 floor setpoint
10.2 First level parameters
LABEL MIN. MAX. U.M. DEF. PASSWORD
PA -90 100 --- 0 password
LABEL MIN. MAX. U.M. DEF. MEASURE INPUTS
/1 -10 10 °C/°F
(7)
0 top and floor probe calibration
LABEL MIN. MAX. U.M. DEF. REGULATOR
rA0 -15 -1 °C/°F
(7)
-2 hysteresis (differential, it is relative to the top and the floor setpoint)
10.3 Second level parameters
LABEL MIN. MAX. U.M. DEF. MEASURE INPUTS
/0 10 11 --- 10 kind of probe (10 = “J” Tc, 11 = “K” Tc)
/1 -10 10 °C/°F
(7)
0 top and floor probe calibration
/2 0 6 --- 3 probes reading speed (0 = fast, ... , 6 = slow)
/4 0 1 --- 0 display of non meaningful zeros (1 = YES)
/8 0 1 --- 1 unit of measure temperature (0 = Fahrenheit degree, 1 = Celsius degree)
LABEL MIN. MAX. U.M. DEF. REGULATOR
rA0 -15 -1 °C/°F
rA1 0 rA2 °C/°F
rA2 rA1 999 °C/°F
(7)
-2 hysteresis (differential, it is relative to the top and the floor setpoint)
(7)
0 minimum value you can assign to the top and the floor setpoint
(7)
300 maximum value you can assign to the top and the floor setpoint
LABEL MIN. MAX. U.M. DEF. STEAM INJECTION
tb0 1 255 s 1 minimum time between two steam injections in succession
tb1 1 255 ds
(8)
10 minimum length of the steam injection
LABEL MIN. MAX. U.M. DEF. FIRST ALARM (it is related to the top temperature)
AA0 1 99 °C/°F
AA1 -99 999 °C/°F
(7)
2 hysteresis (differential, it is relative to AA1, it is important if AA4 1)
(7)
0 first temperature alarm threshold (it is important if AA4 1); look at AA4 as well
AA3 0 999 min 0 first temperature alarm exclusion time since you turn the instrument ON (it is important if
AA4 1)