ETC Unison Heritage Fader Station User Manual

ETC Installation Guide
LinkPower
pigtail
Ground
pigtail
WAGO
Spacers
Unison Heritage Fader Station

Overview

The Unison® Heritage Fader Station connects to the LinkConnect station communication bus. LinkConnect is based on Echelon bidirectional protocol, and uses one pair of wires (data+, data–).
LinkPower is topology free and polarity independent; you can install your LinkPower data runs in any desired combination of bus, star, loop, and home-run. ETC recommends using Belden 8471 (or approved equal) wire. The total combined length of a LinkPower wire run may not exceed 1,640 feet (500m), with a maximum distance of 1,312 feet (400m) between any two devices. The Heritage Fader Station may be installed into an industry standard single gang backbox (provided by others) or a surface mounted backbox (sold separately and available from ETC).
All control wiring should be installed and terminated by a qualified installer and should follow standard wiring installation practices. Leave approximately 10 inches (254mm) of wiring in the backbox for connection and to allow slack for future service needs.
®
LonWorks™ with LinkPower
Note:
ETC requires that all stations be grounded by using grounded metal conduit or a 14 AWG (2.5mm2) ESD drain wire.

Installation

Installation should follow local codes and standard practices. The backbox should be installed square for best results. Ensure that the backbox is clean and free of obstructions and that all wiring is installed correctly.
Heritage stations ship with a termination kit containing a LinkPower pigtail, a ground wire pigtail, spacers, and all required connectors for installation.
Corporate Headquarters London, UK Rome, IT  Holzkirchen, DE Hong Kong  Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong  Tel +852 2799 1220 Service: Web:
www.etcconnect.com
7181M2150
Unison Heritage Fader Station Page 1 of 4 Electronic Theatre Controls, Inc.
 Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK  Tel +44 (0)20 8896 1000  Fax +44 (0)20 8896 2000
Via Pieve Torina, 48, 00156 Rome, Italy  Tel +39 (06) 32 111 683  Fax +44 (0)20 8752 8486
(Americas) service@etcconnect.com
 Rev B  Released 2012-02  ETC intends this document to be provided in its entirety.
 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736
 Ohmstrasse 3, 83607 Holzkirchen, Germany  Tel +49 (80 24) 47 00-0  Fax +49 (80 24) 47 00-3 00
Copyright © 2012 ETC. All Rights Reser ved.  Product informati on and specifications subject to change.
(UK) service@etceurope.com  (DE) techserv-hoki@etcconnect.com
(Asia) service@etcasia.com
ETC Installation Guide
Topology of a single
station installation
Topology of multiple
stations installed in
series
Installed control wire
Pigtail wire
Installed control wire Installed wire to next station Pigtail wire
ground
connection
LinkPower connection
Unison Heritage Series

Connect the Wiring

Step 1: Pull all required wiring to the backbox. Step 2: Terminate and connect LinkPower. LinkPower is topology free and
polarity independent. You may install LinkPower in any combination of bus, loop, star, or home-run.
a: Locate the LinkPower pigtail and two WAGO CAGE CLAMP
connectors from the termination kit.
b: Strip 3/8” (9-10mm) from the ends of each LinkPower wire
(both pigtail and installed LinkPower wire).
c: Use the WAGO connector to connect the installed control wire
to the connectorized pigtail wires provided. Open the terminal levers on the WAGO connector and insert the installed (typically black) Belden 8471 LinkPower wire and the black
lead from the LinkPower pigtail into the terminals. d: Close the levers onto the wires. e: Repeat for the installed (typically
white) Belden 8471 LinkPower wire
and remaining pigtail wire using a
new WAGO connector. f: Install the LinkPower connector
onto the control board.
Step 3: Terminate the ESD drain (ground) wire.
This connection is required only when the control cable is not installed in grounded metal conduit. a: Locate the ground wire pigtail and
one WAGO connector from the
termination kit. b: Strip 3/8” (9-10mm) from the end of each ground wire (both the
provided pigtail and the installed wire).
®
Unison Heritage Fader Station Page 2 of 4 Electronic Theatre Controls, Inc.
Loading...
+ 2 hidden pages