ETC® Install Guide
ES1 Dimmer Bracket and Connector Installation CE
Connector Options
The ES1 is a bare end dimmer for use with non-ETC, or preexisting fixtures. ETC recommends the
following for field installation.
Recommended CE 230V Input Connectors:
• 16A CEE 1PNE
• Schuko plug with earth connection
• UK13A mains connector
• UK15A round-pin connector
WARNING:
Risk of electric Shock! this equipment must be
earthed.
Recommended CE 230V Output Connector:
• White CEE 2P+E 16A connector
WARNING:
Reference the blue label attached to the dimmer’s output lead for important
output information.
This equipment outputs DC power and should be wired to a connector suitable
for DC power only. Do NOT use a standard mains connector.
Connector Installation
Reference the input label of the dimmer for instructions on proper connector installation.
WARNING:
The ES1 Dimmer can ONLY be wired to luminaires with tungsten lamps. Wiring
to any other lamp type will cause dimmer failure.
ES1 Dimmer Bracket and Connector Install Guide Page 1 of 2 Electronic Theatre Controls, Inc.
Corporate Headquarters
London, UK
Rome, IT
Holzkirchen, DE
Hong Kong Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong Tel +852 2799 1220 Fax +852 2799 9325
Service:
Web:
7145M2121
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK Tel +44 (0)20 8896 1000 Fax +44 (0)20 8896 2000
Via Pieve Torina, 48, 00156 Rome, Italy Tel +39 (06) 32 111 683 Fax +44 (0) 20 8752 8486
(Americas) service@etcconnect.com
www.etcconnect.com
Rev C Released 2013-02
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736
Ohmstrasse 3, 83607 Holzkirchen, Germany Tel +49 (80 24) 47 00-0 Fax +49 (80 24) 47 00-3 00
Copyright © 2013 ETC. All Rights Reserved. Product information and specifications subject to change.
(UK) service@etceurope.com (DE) techserv-hoki@etcconnect.com
ETC intends this document to be provided in its entirety.
(Asia) service@etcasia.com

ETC Install Guide
Fixture yoke
Sandwich bracket
Safety cable
mounting holes
Pipe mount bracket
Safety cable
mounting holes
Bracket Options
There are two additional brackets that ship with the ES1 Dimmer. The sandwich bracket should be used
when mounting the dimmer to the yoke of a fixture. The pipe mount bracket should be used when
mounting the dimmer to a lighting truss or pipe.
• A safety cable can be attached through either of the existing holes to the left and right of the
mounting pad.
Sandwich Bracket
The Sandwich bracket includes a metal plate and needed hardware.
Step 1: Secure the fixture yoke between the two bracket plates with the four provided bolts.
Bracket and Connector Installation
Pipe Mount Bracket
The pipe mount bracket includes an L-shaped bracket and hardware.
Step 1: Using two of the bolts provided, attach the bracket to the dimmer as in the graphic below.
Step 2: Attach a hook clamp, half coupler, or other mounting to the bracket.
Note:
Hook clamp, half coupler or other mounting is NOT supplied as part of the pipe mount
bracket.
.,
ES1 Dimmer Bracket and Connector Install Guide Page 2 of 2 Electronic Theatre Controls, Inc.