Essick Air MA0800, MAF2 User Manual

4.5 (2)
Essick Air MA0800, MAF2 User Manual

READ AND SAVE THESE INSTRUCTIONS

MINI-CONSOLE

EVAPORATIVE

HUMIDIFIER

MODEL MA0800

USE AND CARE GUIDE

Adjustable Humidistat

Three Speed Fan

Easy Bottle Fill

Français …......13

Español …….. 25

TO ORDER PARTS AND ACCESSORIES CALL 1.800.547.3888

COMFORT IS IN THE AIR

1B72771

4/2014

PRINTED IN CHINA

IMPORTANT SAFEGUARDS

General Safety Instructions

READ BEFORE USING YOUR HUMIDIFIER

DANGER: means if the safety information is not followed someone will be seriously injured or killed.

WARNING: means if the safety information is not followed someone could be seriously injured or killed.

CAUTION: means if the safety information is not followed someone may be injured.

1.To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other). Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit

into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

2.Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.

3.Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.

4.Keep the humidifier clean. To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier.

5.Do not put foreign objects inside the humidifier.

6.Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.

7.To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.

8.To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.

9.To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.

WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.

WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.

WARNING: To reduce the risk of fire or shock hazard, do not pour or spill water into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.

2

INTRODUCTION

Your new humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air.

As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.

Use only AIRCARE® or Essick Air® brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. The MA0800 humidifiers use wick # MAF 2. Only the AIRCARE® or Essick Air® /MoistAIR® evaporative wick guarantees the certified output of your humidifier. Use of other brands of wicks voids the certification of output and may void your warranty.

HOW YOUR HUMIDIFIER WORKS

Dry air is drawn into the sides of the humidifier, then air is moisturized as it passes through the saturated evaporative wicking filter in the reservoir.

The humidified air is then released through top of the unit.

Description

MA0800

*Output per 24 hrs

8 gallons/30.2 Litres

Capacity of Bottle

1.2 gallons/4.54 Litres

Capacity of Base

1.2 gallons/4.54 Litres

Sq. ft. coverage

2500 (Tight Const.)

1700 (Avg. Const.)

 

Fan Speeds

3

Replacement Wicking Filter

MAF2

Adjustable Humidistat

Yes

Refill Indication

Yes

Controls

Digital

Rubber feet

Yes (6)

ETL Listed

Yes

Volts

60

Hertz ( High Speed)

1.2

Amps (High Speed)

81

*Based on an area with average insulation and an 8’ ceiling height ANSI/AHAM HU-1-1997. SEC. 8.1. Results may vary.

3

NOTES ON LOCATION:

In order to get the most effective use from your humidifier, it is important to position the unit where the most humidity is needed or where the moist air will be circulated throughout the house such as near a cold air return. If the unit is positioned close to a window, condensation may form on the window pane. If this occurs the unit should be repositioned in another location.

Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet.

Due to the release of cool, moist air from the humidifier, it is best to direct air away from thermostat and hot air registers. Position humidifier next to an inside wall on a level place at least 4 inches away from the wall or curtains.

ASSEMBLY

1)Unpack humidifier from carton.

2)Remove all packaging materials. Check to see that you have all of the following items removed from the box, accessory kit and cabinet before discarding the

packaging:

 

Evaporative wicking filter

Manual

WATER FILL

CAUTION: Before filling, ensure unit is turned OFF. Keep grille dry at all times.

WARNING: To reduce the risk of fire or shock hazard, DO NOT pour or spill water into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.

After the humidifier is positioned where it will be

a.

operating you are ready to fill the humidifier. The

bottle lifts straight up and away from the base.

 

Take care not to bump or damage fill valve

 

assembly on the bottom of the bottle.

 

Invert the bottle. Press the valve stem button into the bottle and turn clockwise to lock in open position. Place bottle under the faucet. Fill the bottle, being careful not to allow any debris to get in the bottle. Debris may interfere with the valve seating. Once the bottle is full, press the valve stem button and turn counter clockwise to release and close.

b.

c.

4

CAUTION: Use only EPA Registered Bacteriostat. Under no circumstances should you use Water Treatment products intended for Rotobelt or Ultrasonic humidifiers.

NOTE: We recommend using AIRCARE® or Essick Air® Bacteriostat Treatment PN 1970 when you refill the water reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle.

Place the water bottle back into the humidifier base. When positioned properly, the plunger will open and the water will flow into the base. The base will hold the entire contents of the water bottle. Once the bottle is empty, remove it and repeat the filling process. The humidifier is now filled to capacity. To benefit from less frequent filling let the humidifier exhaust both the water from the bottle and the base before filling.

ABOUT HUMIDITY

Where you set your desired humidity levels depends on your personal comfort level, the outside temperature and the inside temperature.

NOTE: Recent CDC tests show that the chances of flu transmission are greatly reduced at levels of 43% humidity.

You may wish to purchase a hygrometer* to measure the humidity level in your home. The following is a chart of recommended humidity settings.

IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity SET point should be lowered until condensation no longer forms. We recommend room humidity levels do not exceed 50%.

When Outdoor

Recommended

Temperature is:

Indoor Relative

°F

° C

Humidity (RH) is

-20

-30°

15 - 20%

-10°

-24°

20 - 25%

-18°

25 - 30%

10°

-12°

30 - 35%

20°

-6°

35 - 40%

30°

-1°

40 - 45%

*Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888.

NOTE: External hygrometer readings and humidistat readings may differ. Humidity levels can vary significantly even in one room.

OPERATION

Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier should be placed at least FOUR inches away from any walls and away from heat registers. Unrestricted airflow into the unit will result in the best efficiency and performance.

This unit has an automatic humidistat located in the cord that senses the humidity level around the immediate area of the humidifier. It causes the humidifier to cycle on and off to maintain the selected humidity SET point. The fan will turn on when the humidity reading falls 3% below the SET point and will continue to run the humidifier until a reading of 1% above the SET point is achieved.

5

CONTROL PANEL

Digital Display

Press the power button once to turn the unit on*. Initially there is a slight delay while the electronics calibrate.

Two bars (- -) appear during this time. Once calibration is complete a ROOM

humidity reading between 20% - 95% will be displayed. A flashing 20 display indicates that the room humidity is less than 20%.

NOTE: The default settings at initial startup are (LOW) F1 fan speed and 65%

SET humidity. After desired settings are selected by the user, they remain as long as the unit remains plugged in and there is no power interruption. When the unit is unplugged, the original default settings are reinstated.

* Humidifier fan should operate at initial start up. If it does not, refer to “Fan not operating (digital display is illuminated n Trouble Shooting Table.”

HUMIDITY SETTING.

This button allows you to adjust the humidity to suit your needs. This humidifier will automatically cycle on and off as required to maintain the selected setting.

The readout displays both actual (ROOM) and desired (SET) humidity percentage (%) settings when humidity control button is pressed. The ROOM readout has a range of

20% to 95% Relative Humidity (RH). If the room humidity level is equal to or less than 20% RH the display will show a flashing 20. The SET readout has a range of 25% to 65% RH and is adjusted in increments of 5%. Initially depressing the humidity button will display the current humidity setting. Each additional press of the button increases the setting by 5%. A SET point of 65% RH operates the humidifier continuously regardless of the ROOM reading. The humidistat that senses the readings is located on the power cord. Insure that it is free from obstruction.

FAN SPEED

This humidifier is equipped with a 3-speed fan control. Initially depressing the speed button will display the current speed setting. Each push of the speed button advances the mode through the settings of

(HIGH) F3, (MEDIUM) F2 and (LOW) F1.

The selected setting is displayed on the digital readout. The higher the setting,

the faster water is evaporated and released into the air. F1 (LOW) is the quietest setting and is provided for conditions that do not require a rapid evaporation rate.

NOTE: When excessive condensation exists, a lower speed setting is recommended.

6

REFILL INDICATION

When both the bottle and the base are empty, the display alternates the room humidity reading and (FILL), indicating additional water is required.

At this time and refill unit according to the instructions in the WATER FILL section.

CHECK FILTER INDICATOR

The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the

filter. As the wicking filter loads with impurities it gradually loses its wicking capability. When this happens, moisture output is reduced and the humidifier has to work longer to satisfy the selected

setting.

This humidifier has a check filter reminder timed to

appear after 720 hours of operation. When the display shows an alternating “CF” and “room humidity” setting at 5 second intervals it is a reminder to check the filter condition.

NOTE: Some areas have high water mineral content causing the need for more Frequent wicking filter changes.

Reset the Check Filter “CF” function each time you replace a filter by unplugging the unit from the power source, then plug it in again.

Refer to REPLACEMENT OF WICKING FILTER if a build-up of deposits or severe discoloration is evident replace the to restore maximum efficiency.

REPLACEMENT OF WICKING FILTER

CAUTION: Before changing wicking filter, ensure unit is turned OFF. CAUTION: To help prevent bacteria growth

and keep maximum efficiency, the wicking filter should be replaced at least once per season, or more often under hard water conditions. Use AIRCARE®/Essick® /MoistAIR® MAF2 replacement wicking filter.

Replace the evaporative wicking filter at least once per humidification season or more depending on water conditions in your area.

Wicking Filter Replacement

1. Unplug humidifier. Before removing the filter, we recommend moving the humidifier to an area where floor coverings are not susceptible to water

damage (i.e. kitchen or bath areas.)

2. Remove the water bottle and set aside.

Be sure not to bump or damage the fill valve.

7

3. Grasp the housing assembly and lift straight up and away from the base and set aside. The wicking filter is now accessible.

4. Take note of the filter position. Remove the filter. You may want to clean the base at this time. See the "Care and Maintenance" section

of this manual.

5. Install a new wicking filter (MAF2) into the base. Coil the filter and position it between the uprights in the bottom of the

base. The start and finish of the coil should be captured at the center of the base (see diagram) and the filter should be resting on the floor of the base.

6. Return the housing assembly to the top

of the base. Reposition the humidifier to its operating position.

CARE AND MAINTENANCE

Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to wipe out the humidifier base and bottle/reservoir after cleaning. We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home. We also recommend using AIRCARE® or

Essick Air® Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment, PN 1970 or wicks.

1)Turn off unit completely and unplug from outlet.

2)Lift off the chassis.

3)Carry the base to cleaning basin. Lift wick from the base allowing the water to drain. Rinse wick under freshwater only. Do not use soap, detergent, or any other cleaners on the wick. Leave in sink to drain.

REMOVING SCALE

4)Pour out any remaining water from the unit. Fill base and bottle ½ full with water and add 8 oz. (1 cup) of undiluted white vinegar. Let stand 20 minutes.

5)Dampen a soft cloth with white vinegar and wipe out reservoir to remove scale. Rinse the water bottle and base thoroughly with fresh water to remove scale and cleaning solution before disinfecting.

DISINFECTING UNIT

6)Fill the bottle and base ½ full with water and add 1 teaspoon of bleach. Let solution stay for 20 minutes, then rinse with water until bleach smell is gone. Dry interior surfaces with clean cloth. Wipe down the outside of the unit with a soft cloth dampened with fresh water.

7)Refill unit and reassemble per ASSEMBLY instructions.

SUMMER STORAGE

1)Clean unit as outlined in Care & Maintenance section.

2)Discard used wick and any water in the bottle or base. Allow to dry thoroughly before storage. Do not store with water inside unit.

3)Do not store unit in an attic or other high-temperature area, as damage is probable.

4)Install new filter at beginning of season.

8

REPAIR PARTS LIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM NO.

DESCRIPTION

MA0800 PART NO.

1

 

1B72774

Top Assembly

2

 

MAF2

† Filter

3

 

831188-1

Support, Float

4

 

831189

Float, Reservoir

5

 

831187-1

Base

6

 

831190

Foot, Rubber

7

 

831199

Bottle Assembly

8

 

831207

Cap, Screw

9

 

1B72771

Owner’s Manual (not shown)

Order by part number, not by item number. To order, call: 1-800-547-3888

† Stock item - Purchase locally or call 1-800-547- 3888 from the USA or 1-888-744-4689 from Canada to order.

Any attempt to repair the control assembly or motor voids the warranty and may create a hazard unless repair is done by a

qualified service technician.

To order parts, call: USA 1-800-547 3888 or in Canada: 1-888-744-4687

9

TROUBLESHOOTING GUIDE

Trouble

Probable Cause

Remedy

Digital display not

• No Power.

• Check 120 volt power source.

illuminated.

• Power button has not been

• Press power button once to turn on.

 

depressed.

 

Fan not operating

ROOM humidity level is not

• Raise SET humidity level if desired.

(digital display is

3% or more below SET

• Increase fan speed.

illuminated).

humidity level.

• Fill humidifier with water.

 

• Reservoir is empty.

 

Fan running

SET humidity level is 65%.

• A SET humidity percentage of 65%

continuously.

ROOM humidity level has

operates fan continuously. Adjust

 

not reached 1% or more

SET level between 25% - 60%.

 

• Continue to run until desired

 

above SET humidity level.

 

 

humidity level is achieved. This

 

 

may take up to 48 hours initially.

Poor evaporation of

• CHECK FILTER (CF)

• Change to a fresh new wicking

water.

message flashing.

filter.

 

• Mineral buildup on wicking

• NOTE: Local water varies from area

 

filter.

to area and under certain

 

 

conditions minerals will build up

 

 

more rapidly in the wicking filter.

Bottle empties

• This is normal for initial

• Refill bottle for maximum run time.

completely

filling

 

Bottle continues to

• Air is entering water bottle.

• Check for leak in water bottle.

empty after complete

 

• Ensure fill valve position is turned to

filling.

 

closed and valve has no interfering

 

 

debris.

Bottle not emptying.

• Spring Valve Assembly

• Check position of bottle.

 

damaged or missing post in

Reposition so that fill valve on

 

bottom of base.

bottom of bottle is depressed

 

• Base full of water.

by post in bottom of base.

 

• The base will hold the contents of

 

 

 

 

water bottle (1.2gallons). Continue

 

 

to run humidifier to deplete water

 

 

from base.

“CF” message does

• Loss of power or a power

• Replace wicking filter.

not appear even when

failure has caused the CF

 

filter is dirty or

message to prematurely

 

humidifier performance

reset.

 

is clearly reduced.

 

 

Display blinks or fan

• Normal

• No action required.

moves slightly when

 

 

humidifier is plugged in.

 

 

Alternating “F” and

• Reservoir is empty.

• Fill humidifier with water.

room humidity

 

 

displayed.

 

 

 

 

 

Alternating “CF” and

• Wicking filter may be dirty.

• Replace wicking filter.

room humidity

 

• Unplug unit for 30 seconds

displayed.

 

and replug in to clear display.

 

 

 

10

Loading...
+ 23 hidden pages