IMPORTANT SAFEGUARDS

General Safety Instructions

READ BEFORE USING YOUR HUMIDIFIER

DANGER: means if the safety information is not followed someone will be seriously injured or killed.

WARNING: means if the safety information is not followed someone could be seriously injured or killed.

CAUTION: means if the safety information is not followed someone may be injured.

1.To reduce the risk of fire or shock hazard, this humidifier has a polarized plug (one blade is wider than the other). Plug humidifier directly into a 120V, A.C. electrical outlet. Do not use extension cords. If the plug does not fully fit

into the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

2.Keep the electric cord out of traffic areas. To reduce the risk of fire hazard, never put the electric cord under rugs, near heat registers, radiators, stoves or heaters.

3.Always unplug the unit before moving, cleaning or removing the fan assembly section from the humidifier, or whenever it is not in service.

4.Keep the humidifier clean. To reduce the risk of injury, fire or damage to humidifier, use only cleaners specifically recommended for humidifiers. Never use flammable, combustible or poisonous materials to clean your humidifier

5.Do not put foreign objects inside the humidifier.

6.Do not allow unit to be used as a toy. Close attention is necessary when used by or near children.

7.To reduce the risk of electrical hazard or damage to humidifier, do not tilt, jolt or tip humidifier while unit is running.

8.To reduce the risk of accidental electrical shock, do not touch the cord or controls with wet hands.

9.To reduce the risk of fire, do not use near an open flame such as a candle or other flame source.

WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.

WARNING: To reduce risk of fire, electric shock, or injury always unplug before servicing or cleaning.

WARNING: To reduce the risk of fire or shock hazard, do not pour or spill liquid into control or motor area. If controls get wet, let them dry completely and have unit checked by authorized service personnel before plugging in.

2

INTRODUCTION

Your new humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air.

As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency.

Use only AIRCARE® or Essick Air® brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. This humidifier uses two wicks # 1040. Only the AIRCARE® or Essick Air® evaporative wick guarantees the certified output of your humidifier. Use of other brands of wicks voids the certification of output and may void your warranty.

HOW YOUR HUMIDIFIER WORKS

Your new evaporative humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water in the air.

Once the wick becomes saturated, air is drawn in, passes through the wick and moisture is absorbed into the air. All evaporation occurs in the humidifier so any residue remains in the wick.

Air is drawn in by the centrally positioned fan

Humidified air is released into the air through

the two side vents

This natural process of evaporation creates no white dust like some other humidifiers

Description

5D6 700

*Output per 24 hrs

5 gallons

Water Capacity

3 Gallons

Sq. ft. coverage

1700 (Tight Constr.)

1100 ( Avg. Constr.)

 

Fan Speeds

4

Replacement Wicks (2 required)

1040

Air Purifying Filter (Optional)

1050

Adjustable Humidistat

Yes

Controls

Digital

ETL Listed

Yes

Volts

120

Hertz

60

Watts

40

* Based on an area with average insulation and an 8’ ceiling height.

NOTES ON LOCATION:

In order to get the most effective use from your humidifier, it is important to position the unit where the most humidity is needed or where the moist air will be circulated throughout the house such as near a cold air return. If the unit is positioned close to a window, condensation may form on the window pane. If this occurs the unit should be repositioned in another location.

Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet.

Due to release of cool, moist air from the humidifier, it is best to direct air away from

3

Essick Air 5D6700, HDC3T User Manual

thermostat and hot air registers. Position humidifier next to an inside wall on a level place at least 4 inches away from the wall or curtains.

ASSEMBLY

1)Unpack humidifier from carton.

2)Remove all packaging material, wicks, etc. from cabinet. REMOVE THE PLASTIC WRAP FROM AROUND EACH WICK.

3)Place the wicks in position by sliding them into the mounting ribs molded into the bottom of the cabinet.

4)Insert the plastic platform with the circular cutout (transitional molding) on top of the mounted wicks. Note that the transitional molding is notched and marked

“FRONT” to indicate proper placement.

Transitional

Molding

Cabinet/ Water reservoir

Air Intake Section of Grille

Digital Control Panel

Air Exit

Section

of Grille

1040 Wicks (2 required)

Optional 1050

Air Purifiing Filter

Chassis

BACK VIEW

Replacement Parts Available For Purchase

Description

Part Number

Chassis (Top portion of unit)

1B72700

Cabinet

1B71784

Transitional Molding

1B71786

Humidifier Wicks (2 Required)

1040

Air Purifying Filter (Optional)

1050

WATER FILL

CAUTION: Before filling, ensure unit is turned OFF and unplugged.

1)Before replacing the chassis, fill the cabinet with unsoftened water. DO NOT POUR WATER OVER THE ELECTRICAL CHASSIS. Fill the cabinet only through the opening between the wick and the cabinet sidewall. Note the MAX. notation on the side wall of the cabinet. DO NOT OVERFILL. Cabinet capacity is 3.0 gallons.

NOTE: We recommend using AIRCARE® or Essick Air® Bacteriostat Treatment when you refill the water reservoir to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle.

Under no circumstances should you use Water Treatment products intended for Rotobelt or Ultrasonic humidifiers.

4

ABOUT HUMIDITY

Where you set your desired humidity levels depends on your personal comfort level, the outside temperature and the inside temperature.

NOTE: Recent CDC tests show that the chances of flu transmission are greatly reduced at levels of 43% humidity.

You may wish to purchase a hygrometer* to measure the humidity level in your home. The following is a chart of recommended humidity settings.

IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity SET point should be lowered until condensation no longer forms. We recommend room humidity levels do not exceed 50%.

When Outdoor

Recommended

Temperature is:

Indoor Relative

°F

° C

Humidity (RH) is

-20

-30°

15 - 20%

-10°

-24°

20 - 25%

-18°

25 - 30%

10°

-12°

30 - 35%

20°

-6°

35 - 40%

30°

-1°

40 - 45%

*Model 1990 digital hygrometer is available for purchase by calling 1-800-547-3888.

NOTE: External hygrometer readings and humidistat readings may differ. Humidity levels can vary significantly even in one room.

OPERATION

Plug cord into wall receptacle. Your humidifier is now ready for use. The humidifier should be placed at least FOUR inches away from any walls and away from heat registers. Unrestricted airflow into the unit will result in the best efficiency and performance.

NOTE: This unit has an automatic humidistat located on the cord that senses the humidity level around the immediate area of the humidifier. It turns the humidifier on when the relative humidity in your home is below the humidistat setting and will turn the humidifier off when the relative humidity reaches the humidistat setting.

DIGITAL DISPLAY

PRESS TO

INCREASE

HUMIDITY

HUMIDITY CONTROL

PRESS AND HOLD TO TURN UNIT ON PUSH TO ADJUST FAN SPEED

CONTROL PANEL

TO TURN ON/OFF

For initial operation, plug the unit in (the display will show - -). Press the speed button and hold for 5 seconds to turn the unit on or off.

FAN SPEED

The 5D6700 has a four speed digital control panel.

1)Press the SPEED button to adjust the fan speeds.

2)The speeds: High (F4) - Low (F1) display on the digital panel

3)The hygrometer on the cord reads the current room humidity and displays the percentage on LCD panel.

4)To set the desired humidity, press the HUMIDITY button. Each successive push increases the humidity in 5% increments. The range is 25% to 65%.

5)At 65% the humidifier will run constantly with or without water.

NOTE: If excessive condensation occurs, reduce fan to a lower speed setting

CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille dry at all times.

5

Control Lock Display

CHECK FILTER

The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the filter. As the filter loads with impurities it gradually loses its wicking capability. When this happens, moisture output is reduced and the humidifier has to work longer to satisfy the selected setting

1)This humidifier has a check filter reminder timed to appear after 720 hours of operation. When the Check Filter (CF) message is displayed, disconnect the power cord and check the condition of the filter. If a build-up of deposits or severe discoloration is evident replace the filter to restore maximum efficiency.

2)The CF function is reset after plugging the unit back in.

CONTROL LOCK FEATURE

Check Filter

Function Display

To avoid unwanted tampering with the humidifier settings the controls can be locked.

ACTIVATION PROCEDURE

After the humidifier functions have been set up, hold the Speed and Humidity buttons down for 5 seconds. The display will show “CL” for 2 seconds.

Release the buttons and the control will resume the display of the room humidity. The humidifier will continue to function with the locked in settings. If buttons are operated while “CL” is active, the “CL” is displayed and settings are unaffected.

DEACTIVATION PROCEDURE

To deactivate the “CL” function simply press and hold both buttons for 5 seconds. “CL” will flash at the rate of 1 second on and 1 second off for a period of 2 seconds and then resume the display of room humidity.

REPLACEMENT OF WICK

CAUTION: Before changing wick, ensure unit is turned OFF and unplugged.

NOTE: This unit uses 2 model 1040 wicks. Replace the wick at the beginning of each season, and more often in areas with hard water.

1)Lift off chassis and set aside.

2)Lift off transition molding tray, then remove and discard used wicks.

3)Install new wicks according to instructions listed in ASSEMBLY section.

OPTIONAL AIRCARE ® FILTER

This humidifier is built to accommodate the two-stage 1050 optional air purifying filter. The first stage is a high-efficiency, electrostatically-charged filter media which traps dust, pollen and airborne pollutants. The second stage is an activated carbon media which absorbs odors from cooking, pets or tobacco smoke.

We recommend replacing the AIRCARE® filter at least once a year, more often if necessary. When the white filter media is coated with a layer of dust and dirt, it is time to replace the filter.

NOTE: The certified water output of your humidifier will be reduced when using the AIRCARE® filter. The AIRCARE® filters are optional and are not required for

normal operation of the humidifier. necessary. When the white filter media is coated with a layer of dust and dirt, it is time to replace the filter.

6

INSTALLATION

1)To install the optional air filter, remove the chassis (top portion of the unit).

2)From the rear, locate the air filter compartment and unlatch the door.

3)Place the 1050 AirCare® air filter into the compartment and close the door.

4)Replace the chassis onto the cabinet.

Unlatch and Open

Filter Compartment

Door

Lift Top of Unit Away from Base

Slide 1050 Air Filter into Compartment

CARE AND MAINTENANCE

Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal growth. Ordinary household bleach is a good disinfectant and can be used to wipe out the humidifier base and bottle/reservoir after cleaning .We recommend cleaning your humidifier at least once every two weeks to maintain optimum environmental conditions for your home. We also recommend using AIRCARE® or

Essick Air® Bacteriostat Treatment each time you refill your humidifier to eliminate bacterial growth. Add bacteriostat according to the instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat Treatment, part number 1970.

1)Turn off unit and unplug from outlet.

2)Lift off chassis and transitional molding from cabinet and set aside.

3)Lift wicks from cabinet, allow water to drain from wicks into cabinet and then set aside.

4)Empty cabinet into sink. Remove any remaining water from cabinet with a sponge.

REMOVING SCALE

5)Fill cabinet with water and then add 8oz. (1cup) of white vinegar. Let solution stay 20 minutes, then empty.

6)Clean all interior surfaces of cabinet with a soft brush. Dampen soft cloth with white vinegar and wipe out cabinet to remove scale.

7)Rinse cabinet thoroughly with fresh water to remove scale and cleaning solution.

DISINFECTING UNIT

8)Fill cabinet with water and add 3 teaspoons of chlorine bleach. Let solution stand for 20 minutes.

9)Empty and rinse thoroughly.

10)Refill cabinet with water and re-assemble per WATER FILL instructions.

SUMMER STORAGE

1)Clean unit as outlined in Care & Maintenance section.

2)Discard used wicks and any water in the cabinet and allow unit to dry thoroughly before storage. Do not store with water inside unit.

3)Do not store unit in an attic or other high-temperature area, as damage will occur.

4)Install new wick at beginning of season.

7

HUMIDIFIER TWO YEAR LIMITED WARRANTY POLICY

SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS.

This warranty is extended only to the original purchaser of this humidifier when the unit is installed and used under normal conditions against defects in workmanship and materials as follows:

Two (2) years from date of sale on the unit, and

Thirty (30) days on wicks and filters, which are considered disposable components and should be replaced periodically.

The manufacturer will replace the defective part/product, at its discretion, with return freight paid by the manufacturer. It is agreed that such replacement is the exclusive remedy available from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

Exclusions from this warranty

We are not responsible for replacement of wicks and filters.

We are not responsible for any incidental or consequential damage from any malfunction, accident, misuse, alterations, unauthorized repairs, abuse, including failure to perform reasonable maintenance, normal wear and tear, nor where the connected voltage is more than 5% above the nameplate voltage.

Alterations include the substitution of name brand components including, but not limited to wicks and bacteria treatment.

We are not responsible for any damage from the use of water softeners or treatments, chemicals or descaling materials.

We are not responsible for the cost of service calls to diagnose the cause of trouble, or labor charge to repair and/or replace parts.

No employee, agent, dealer or other person is authorized to give any warranties or conditions on behalf of the manufacturer. The customer shall be responsible for all labor costs incurred.

This warranty will be null & void if purchaser attempts to repair or replace any parts which are mechanical or electrical.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.

How to obtain service under this warranty

Within the limitations of this warranty, purchaser with inoperative units should contact customer service at 800-547-3888 for instructions on how to obtain service within warranty as listed above.

This warranty gives the customer specific legal rights, and you may also have other rights which vary from province to province, or state to state.

Register your product at www.essickair.com or www.AIRCAREproducts.com.

8

Loading...
+ 16 hidden pages