All rights reserved. Translation of the original version in German.
3
Version 1.1 (12/2016)
Information about this manual
1 InformatIonaboutthIsmanual
Read this manual carefully before starting to use the device.
Keep the manual so you can refer to it at a later date if you
need to. If you hand over the device to other persons for use,
please hand over the operating manual as well.
Symbols used:
Attention!
This indicates a hazard.
Note.
This section contains important additional information.
2 safetyInstructIons
The device is not a toy; do not allow children to play
with it. Do not leave packaging material lying around,
as it can be dangerous in the hands of a child.
Do not open the device: it does not contain any components that need to be serviced by the user. In the
event of an error, please return the device to the service department.
The device may only be operated indoors and must
be protected from the effects of damp and dust, as
well as solar or heat radiation.
4
Function
Using the device for any purpose other than that described in this operating manual does not fall within
the scope of intended use and shall invalidate any
warranty or liability. This also applies to any conversion or modification work. The device is intended for
private use only.
3 functIon
The MAX! Radiator Thermostat is responsible for regulating the radiators within the MAX! system. During ventilation, the MAX! Radiator Thermostat automatically reduces
the temperature in a room in order to save on energy costs.
Communication between the MAX! components is bidirectional. This ensures that the information sent reaches the
recipient.
The configuration of the MAX! Radiator Thermostat depends
on the system variant used. You have the possibility to choose
between the following two variants:
MAX! House Solution
This is the solution for the entire house. With a MAX!
Cube, all settings of connected devices in your house
can comfortably be made via the MAX! software.
By using the MAX! Cube, several MAX! Radiator solutions and MAX! Room solutions can be connected to
5
Function
a new MAX! House solution in a new installation. In
this installation, the MAX! Eco Switch can optionally
be integrated.
MAX! Room solution
In the room solution, the settings of all connected
devices in your room can comfortably be made via
the MAX! Wall Thermostat+. Up to 8 MAX! Radiator
Thermostats and 8 MAX! Window Sensors can be connected and controlled via the MAX! Wall Thermostat+.
The MAX! Wall Thermostat+ has an internal sensor
that measures the temperature in the room and cyclically transmits it to the radiator thermostats.
With a MAX! Cube, the solution can be extended to a
House solution.
6
Device overview
4 DevIceovervIew
A
B
G
C
F
D E
A Automatic mode (Auto), manual mode (Manu), holiday
mode ( ), boost function ()
open-window-function ( )
B Display of setpoint temperature
C Auto/Manu button: Switch between automatic and man-
ual mode, exit the holiday mode
D Handwheel for temperature settings
E Boost button: Activate the boost function, confirm, start
teach-in procedure
F Switch between reduction and comfort temperature
G Reduction/comfort temperature (
symbol (), antenna symbol (radio synchronicity),
( ), activity symbol ( )
7
), empty battery
Display content in normal mode
5 DIsplaycontentInnormalmoDe
The setpoint temperature is displayed during normal operation, along with the mode. In the example, the MAX! Radiator Thermostat is in automatic mode (Auto) and the
temperature () of 21.0°C is set.
indicates that the connection to the taught-in component
has been established.
The antenna symbol ( )
comfort
6 start-up
6.1 InsertIng (replacIng) batterIes
To insert the batteries into the MAX! Radiator Thermostat,
please proceed as follows:
• Remove the battery compartment cover by pushing it
forwards.
• Insert 2 LR06/mignon/AA batteries in the battery compartment, making sure they are the right way round.
• Reattach the battery compartment cover and latch it into
place.
After inserting batteries, the radiator thermostat has to be
mounted on the radiator (see sec. „6.2 Installation on the
radiator“ on page 9). The radiator thermostat starts an
8
Start-up
adapting run afterwards (see sec. „6.3 Adapting run“ on
page 17).
A battery symbol (
) indicates that the batteries need to
be replaced. After removing the batteries, you should wait
approx. 1 minute before inserting the new ones.
The service life of new alkaline batteries is approximately two years.
This device does not support operation with rechargeable batteries.
Never recharge standard batteries. Doing so will present a risk of explosion. Do not throw the batteries
into a fire! Do not short-circuit batteries.
Used batteries should not be disposed of with
regular domestic waste! Instead, take them to
your local battery disposal point.
6.2 InstallatIonontheraDIator
The MAX! Radiator Thermostat is easy to install and can be
done without draining heating water or intervening in the
heating system. No special tools are required, nor does the
heating have to be switched off.
The union nut attached to the radiator thermostat can be
used universally and without accessories for all valves with
a thread size of M30 x 1.5 from the most popular manufacturers such as
9
Start-up
• Heimeier
• MNG
• Junkers
• Landis+Gyr (Duodyr)
• Honeywell-Braukmann
• Oventrop
• Schlösser
• Comap
• Valf Sanayii
• Mertik Maxitrol
• Watts
• Wingenroth (Wiroflex)
• R.B.M
• Tiemme
• Jaga
• Siemens
• Idmar
By means of the adapters in the delivery, the device can be
installed on radiator valves of type Danfoss RA, Danfoss RAV
and Danfoss RAVL.
6.2.1 Removing the old dial
Rotate the thermostat dial to the maximum value (1) (anti-clockwise). The thermostat dial then no longer presses
against the valve spindle, making it easier to remove.
There are different ways of fixing the position of the thermostat dial: