80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
4 Amps
47-63 Hz
500 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 12.94%, 50% Load)
0.40 0.68 55.86% 10% 62.83 11.77/0.02 3.36/1.07 5.05/1.07 5.13/0.2 51.07 81.29%
0.57 0.91 24.47% 20% 118.61 11.76/0.05 3.35/2.14 5.03/2.13 5.12/0.4 102.43 86.36%
1.31 0.97 12.94% 50% 292.90 11.82/0.12 3.32/5.36 5/5.31 5.08/1.01 256.25 87.49%
2.70 0.98 14.08% 100% 609.60 11.91/0.24 3.29/10.73 4.94/10.62 5.02/2.02 513.13 84.18%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Enermax Technology Corporation
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current