Endress+Hauser Nivector FTI26 Technical Information

Page 1
TI01384F/00/EN/01.18 71398859 2018-01-26
Products
Solutions Services
Technical Information
Nivector FTI26
Capacitive
Point level switch for powdered and fine-grained solids
Application
Reliable minimum or maximum detection of powders or fine-grained bulk solids in silos.
• Typical application examples: plastic granules, detergent, grain, sugar, spices, milk powder, animal feed
• Easy installation thanks to compact design - even in tight conditions or where access is restricted.
• Also suitable for use in – Food industry – Hazardous atmospheres formed by combustible dust, zone 20 – Process temperatures of –20 to +80 °C (–4 to +176 °F).
Your benefits
• Onsite function check via LED indication
• Robust stainless steel housing, optionally available with M12x1 connector with IP69 protection
• Easy and cost-effective commissioning: Precalibration in factory (plug and play)
• Hygienic design, 3-A and EHEDG certificates
• Meets the requirements of EU 1935/2004
• FDA-compliant
• DC-PNP Output and IO-Link communication
Page 2

Table of contents

Nivector FTI26
About this document ........................ 3
Document conventions .......................... 3
Function and system design ................... 4
Measuring principle ............................ 4
Measuring system ............................. 4
Input ..................................... 5
Measured variable ............................. 5
Measuring range .............................. 5
Output ................................... 5
Switch output ................................ 5
Power supply .............................. 6
Supply voltage ............................... 6
Power consumption ............................ 6
Current consumption ........................... 6
Electrical connection ........................... 6
Cable specification ............................. 8
Length of connecting cable ....................... 8
Overvoltage protection .......................... 8
Performance characteristics ................... 8
Reference operating conditions .................... 8
Switch-on behavior ............................ 8
Influence of ambient temperature .................. 8
Switch-on delay .............................. 8
Switching delay ............................... 8
Installation ................................ 9
Mounting location ............................. 9
Installation instructions ......................... 9
Materials .................................. 14
Surface roughness ............................ 15
Operability ............................... 15
Operating concept for devices with IO-Link ........... 15
IO-Link information ........................... 15
IO-Link download ............................ 15
Light signals (LEDs) ........................... 16
Device search ............................... 16
Sensor check ............................... 16
Medium calibration ........................... 16
Function test ............................... 16
Certificates and approvals ................... 17
CE mark ................................... 17
C-tick symbol ............................... 17
RoHS ..................................... 17
RCM-Tick marking ............................ 17
EAC conformity .............................. 17
Pressure equipment with allowable pressure
≤ 200 bar (2 900 psi) .......................... 17
Ex approval ................................ 18
Sanitary compatibility ......................... 18
Manufacturer's Declaration ...................... 18
Ordering information ....................... 18
Accessories ............................... 19
Adapter .................................. 19
Protector G 1½'', R 1½'' ......................... 19
Lock nut .................................. 19
Protection cover ............................. 20
Test magnet ............................... 20
Plug-in jack, connection adapter ................... 20
Environment .............................. 11
Ambient temperature range ..................... 11
Storage temperature .......................... 11
Relative humidity ............................ 11
Climate class ............................... 11
Altitude ................................... 11
Degree of protection .......................... 11
Shock resistance ............................. 11
Vibration resistance ........................... 11
Cleaning .................................. 11
Electromagnetic compatibility .................... 11
Reverse polarity protection ...................... 11
Short-circuit protection ......................... 12
Supplementary documentation ............... 21
Operating Instructions ......................... 21
Supplementary documentation ................... 21
Certificates ................................. 21
Registered trademarks ...................... 21
Process .................................. 12
Process temperature range ...................... 12
Process pressure range ......................... 12
Process fluid ................................ 12
Mechanical construction .................... 13
Connector ................................. 14
Weight ................................... 14
2 Endress+Hauser
Page 3
Nivector FTI26

About this document

Document conventions Symbols for certain types of information

Symbol Meaning
Permitted
Indicates procedures, processes or actions that are allowed.
Preferred
Indicates procedures, processes or actions that are preferred.
Tip
Indicates additional information.
Reference to page
Refers to the corresponding page number.
Symbols in graphics
Symbol Meaning
1, 2, 3 ... Item numbers
A, B, C, ... Views
Endress+Hauser 3
Page 4

Function and system design

1
2
Nivector FTI26

Measuring principle

Measuring system

The sensor surface of the Nivector evaluates the different dielectric values of air and bulk solids. If the bulk solids come into contact with the sensor surface, the electronics change the switch status. The Nivector can be switched to either minimum of maximum fail-safe mode, ensuring quiescent current operation in all applications. The switch status is indicated by an LED. A guard electrode eliminates interference factors due to the vessel wall or possible buildup, for example.
Depending on the fail-safe mode selected and the level, the Nivector switches and signals in the following cases:
• When point level is reached
• In the event of a problem
• In the event of a power failure (electrical switch is locked)
The measuring system comprises a Nivector point level switch, e. g. for connecting to PLCs or an IO­Link master as per DIN EN 61131-9. A suitable miniature contactor or a solenoid valve can be connected directly to the point level switch.
 1 Application examples
1 Overfill protection or upper level detection (MAX) 2 Dry-running protection or lower level detection (MIN)
System integration
For devices with IO-Link, an IO-DD is available in the Downloads area of the Endress+Hauser website →  15.
A0035880
4 Endress+Hauser
Page 5
Nivector FTI26

Input

Measured variable

Measuring range

Switch output

Level (point level switch)
The change in medium capacitance is detected by the electrode in contact with the process.
Bulk solids, e. g. foodstuffs in powder form
• Dielectric constant (Dk) > 1.3
• Grain size < 10 mm

Output

Designation
• 3-wire DC-PNP Positive voltage signal at the switch output of the electronics
• 2 DC-PNP outputs, switched using XOR operation
• 200 mA connectable load (short-circuit proof)
Devices with IO-Link
• 3- or 4-wire DC-PNP
• 2 DC-PNP outputs, freely configurable
• 1 switch output active: 200 mA
• Both switch outputs active: Connectable load of 105 mA each (short-circuit proof)
1) Product Configurator, order code for "Power supply; output"
2) Unlike the IO-Link standard, the SIO mode supports 200 mA.
2)
connectable load (short-circuit proof)
Option
4
7
1)
• Safety-related switching: MIN or MAX point level. The electrical switch opens if the point level is reached or if faults or a power outage occur. – Maximum point level detection (MAX): e. g. for overfill protection
The device keeps the electrical switch closed as long as the sensor is not yet covered by medium. This is also the case for devices with IO-Link if the measured value is inside the process window.
– Minimum point level detection (MIN): e. g. for dry-running protection
The device keeps the electrical switch closed as long as the sensor is covered by medium. This is also the case for devices with IO-Link if the measured value is outside the process window.
• Residual voltage: < 3 V
• Residual current: < 100 µA
Endress+Hauser 5
Page 6

Power supply

0.5A
L– L+
2
1
3
4
K
0.5A
L–
L+
2
1
3
4
K
1
21
2
1
41
4
L–
L+
C/Q1
2
1
3
4
SIO
IO-Link
0.5 A
K1
Q2
Nivector FTI26

Supply voltage

Power consumption

Current consumption

Electrical connection

12 to 30 V DC
IO-Link communication is guaranteed only if the supply voltage is at least 18 V.
< 1.2 W (at max. load:200 mA)
< 20 mA
Voltage source: Non-hazardous contact voltage or Class 2 circuit (North America). The device must be operated with a fine-wire fuse 500 mA (slow-blow).
Depending on the evaluation of the switch outputs, the device works in the MAX (maximum point level detection) or MIN (minimum point level detection) modes.
M12 plug
Electrical connection Mode of operation
M12 plug MAX MIN
SymbolsKDescription
Yellow LED (ye) lit Yellow LED (ye) not lit External load
Devices with IO-Link
• IO-Link: Communication on C/Q1; switch mode on Q2.
• SIO mode: If there is no communication, the device switches to the SIO mode = standard IO mode.
The factory-set functions for the MAX and MIN modes can be changed via IO-Link.
Electrical connection IO-Link with one switch output
M12 plug
1 Supply voltage + 2 DC-PNP (Q2) 3 Supply voltage ­4 C/Q1 (IO-Link communication or SIO mode)
1)
A0034411
1) Product Configurator, order code for "Power supply; output", option 7
6 Endress+Hauser
Page 7
Nivector FTI26
0.5A
L– L+
2
1
3
4
K2
Q1
K1
Q2
0.5A
L– L+
2
1
3
4
K1
K2
1
2
1
4
4
1
1 2
21
41
Electrical connection Both switch outputs active simultaneously
M12 plug
1 Supply voltage + 2 DC-PNP (Q2) 3 Supply voltage ­4 DC-PNP (Q1)
1) Depending on configuration
2) Current consumption with two outputs connected: < 25 mA
1) 2)
A0035998
Function monitoring
In the order configuration: With two-channel evaluation, functional monitoring of the sensor is also possible in addition to level monitoring, provided that no other monitoring option has been configured via IO-Link.
When both outputs are connected, the MIN and MAX outputs assume opposite states (XOR) when the device is operating fault-free. In the event of an alarm condition or a line break, both outputs are de-energized.
Connection for function monitoring using XOR operation
Sensor covered
Sensor uncovered
Fault
A0022917
Symbols
K1/K2
Description
LED lit LED not lit Fault or warning External load
Yellow LED
(ye)
Red LED
(rd)
Endress+Hauser 7
Page 8
Nivector FTI26
1
3
0.5A
L–
L+
2
K
+
L–
L+
3
0.5A
1
2
K
+
3
23
2
2323
Valve plug
Depending on the assignment of the connector, the device works in either the MAX or MIN mode.
Electrical connection Mode of operation
Valve plug MAX MIN
A0022900
SymbolsKDescription
Yellow LED (ye) not lit Yellow LED (ye) lit External load

Cable specification

Length of connecting cable

Overvoltage protection

Reference operating conditions

Switch-on behavior

• M12 plug: IEC 60947-5-2
• Valve plug – Cable cross-section: Max.1.5 mm2 (16 AWG) – Ø3.5 to 6.5 mm (0.14 to 0.26 in)
• Max. 25 Ω/core, total capacity < 100 nF
• IO-Link communication: < 10 nF
Overvoltage category II

Performance characteristics

Accuracy in accordance with DIN EN 61298-1 based on 100% (factory adjustment)
• Non-repeatability: ± 1 %
• Uncertainty, absolute: ±  2.5 %
• Hysteresis: + 0.5 % ±  0.5 %
Horizontal orientation:
• Ambient temperature: 20 °C (68 °F) ±5 °C
• Medium temperature: 20 °C (68 °F) ±5 °C
• Process pressure: 1 bar abs. (14.5 psi)
• Medium: Sliding earthed metal plate in front of sensor.
< 2 s
Influence of ambient
Maximum 0.1 %/K
temperature

Switch-on delay

Switching delay

< 2 s until correct switch status is set. Prior to that, the switch outputs are in a blocked state.
• 0.5 s when sensor is covered
• 1.0 s when sensor is uncovered
• IO-Link communication: 0.3 to 60 s configurable
• Can be ordered as option: 0.3 s; 1.5 s or 5 s (when sensor is covered or uncovered)
1) See Product Configurator, order code 570, option HS
8 Endress+Hauser
1)
Page 9
Nivector FTI26
≥20 (0.8)
G 1"
≥20 (0.8)
G 1"
≥20 (0.8)
G 1"
14 (0.55)
G 1"

Installation

Mounting location

Installation instructions

Lateral mounting in bulk solids silos, indoors or outdoors, e. g. in silo
For installation in metallic or non-metallic bulk solids silos, follow the EMC guidelines→  11.
• Engineering unit mm (in)
• Sensor surface ≥ 20 mm (0.79 in) projecting into silo (when installing with weld-in adapter 20 mm (0.79 in)
• Silo wall thickness < 35 mm (1.38 in) or welding socket G 1" < 50 mm (1.97)
Examples
A0035881
 2 Standard installation with external G 1" threaded adapter
 3 Where buildup occurs on the silo wall with internal G 1" threaded adapter
 4 Bore hole in silo wall with lock nuts, can be ordered as an accessory →  19
 5 Installation with weld-in adapter, can be ordered as an accessory →  19
A0036360
A0036359
A0036362
Endress+Hauser 9
Page 10
Nivector FTI26
≥20 (0.8)
G 1½"
≥20 (0.8)
G 1"
 6 Installation with Tri-Clamp and NA Connect provided by customer, can be ordered as an accessory
→  19
Installation with protector
• Protection of point level switch against damage by particularly abrasive or coarse product
• Outflow protection in silo for functional testing when silo is full
 7 Installation with protector, can be ordered as an accessory →  19
A0036363
A0036361
Installation with protection cover
• Installation with protection cover against impact effects or
• in hazardous area Please also ensure compliance with the corresponding national standards and regulations and the Safety Instructions or Installation or Control Drawings →  21
• Fit the protection cover before the device is put into operation.
A0036433
 8 Installation with protection cover, included in scope of delivery for hazardous areas or can be ordered as
an accessory →  19
10 Endress+Hauser
Page 11
Nivector FTI26
90 (194)
80 (176)
70 (158)
60 (140)
50 (122)
40 (104)
30 (86)
20 (68)
10 (50)
0 (32)
1
T
T
40 (104)
0 (32)
10 (50)
20 (68)
30 (86) 50 (122) 90 (194)
80 (176)
70 (158)
60 (140)
p
a

Ambient temperature range

Environment

Storage temperature

Relative humidity

Climate class

Altitude

Degree of protection

Shock resistance

Vibration resistance

Cleaning

Electromagnetic compatibility

A0036858
1) Ex devices Tp) Process temperature = °C (°F) Ta) Ambient temperature = °C (°F)
–25 to +85 °C (–13 to +185 °F)
Pressure: 1 bar abs. (14.5 psi)
0 to 100 %
DIN EN 60068-2-38/IEC 68-2-38: Test Z/AD
Up to 2 000 m (6 600 ft) above sea level
• IP65/67 NEMA Type 4X Enclosure (M12 plug for plastic housing cover)
• IP66/68/69 NEMA Type 4X/6P Enclosure (M12 plug for metal housing cover)
• IP65 NEMA Type 4x Enclosure (ISO4400 M16/NPT ½" valve plug for plastic housing cover)
In accordance with EA inspection, prEN 60068-2-27:2007: a = 300 m/s 2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms
In accordance with Fh inspection, EN 60068-2-64:2008: a(RMS) = 50 m/s2, f = 5 to 2 000 Hz, t = 3 planes x 8 h
Resistant to typical cleaning agents from the outside. Passed Ecolab test.
The electromagnetic compatibility requirements outlined in the IEC/EN 61326 series for "industrial environments" are fulfilled when the device is installed in metallic vessel or metallic pipes. Emission requirements for class B equipment are met. For details, refer to the Declaration of Conformity.
If the device is installed in plastic structures, its function may be influenced by strong electromagnetic fields. Emission requirements for class A equipment are met (only for use in "industrial environments").

Reverse polarity protection

Endress+Hauser 11
Integrated; no damage in the event of reverse polarity or short-circuit
Page 12
Nivector FTI26

Short-circuit protection

Process temperature range

Process pressure range

Process fluid

• Overload protection/short-circuit protection at I > 200 mA
• IO-Link communication: 105 mA each if both switch outputs are active
Intelligent monitoring: Testing for overload at intervals of approx. 1.5 s; normal operation resumes once the overload/short-circuit has been rectified.

Process

–20 to +80 °C (–4 to +176 °F)
For Ex devices: –20 to +75 °C (–4 to +167 °F)
–1 to +6 bar (–14.5 to +87 psi)
Powdery and fine-grained bulk solids
• Grain size < 10 mm
• Dielectric constant  1.3
• Default values: εr > 1.6 with protector, εr > 2.0 without protector
12 Endress+Hauser
Page 13
Nivector FTI26
A
B C
H1
H2
H3
H4
H5
!35
(1.38)
G1"G1"
H5
H1
H2
H3
H4
H1
H2
H3
H4
G1"
H5
!31.5
(1.24)
!31.5
(1.24)
42.5 (1.7)

Mechanical construction

Exact dimensions are available in the Product Configurator on the Endress+Hauser website:
www.endress.com → Product finder → On the product page, click the "Configure" button to the
right of the product photo.
Engineering unit mm (in)
A0036387
A Nivector FTI26 plastic with M12 plug B Nivector FTI26 stainless steel with M12 plug, with optional ground terminal C Nivector FTI26 stainless steel with valve plug
Height measurement
H1 Housing cover 20.5 (0.81) 16 (0.36)
H2 Housing 43.6 (1.72)
H3 Process connection 52 (2.05)
H4 Sensor 20 (0.79)
H5 Nivector FTI26 overall
Designation A B C
136 (5.35) 131.2 (5.17)
dimensions
Additional accessories for hygiene sector and hazardous areas: weld-in adapter G 1", Tri-Clamp 2", protection cover→  19
Endress+Hauser 13
Page 14
Nivector FTI26
40 (1.6)
51.5 (2.0)

Connector

Weight

Materials

Dimensions mm (in)
Connection plug with PPSU plastic housing cover
 9 Valve plug M16, NPT ½"
• Plastic with M12 plug: 118 g (4.162 oz)
• Plastic with valve plug120 g (4.232 oz):
• Stainless steel with M12 plug240 g (8.465 oz):
• Stainless steel with valve plug: 243 g (8.465 oz)
• Stainless steel with M12 plug and protection cover: 288 g (10.158 oz)
Wetted materials
Component part Material Product Configurator
Sensor 316L (1.4404), ECTFE
Polycarbonate Order code 110, option WDG
Protector G  1½" Material PBT-GF
Protector R 1½" Order code 620, option PB
O-ring EPDM
1)
2)
Order code 110, option WDJ
Order code 620, option PA
A0021859
1) The material ECTFE meets the requirements of EU 1935/2004, 10/2011, 2023/2006 and
FDA 21 CFR 177.1380
2) The material meets the requirements of EU 1935/2004, 10/2011, 2023/2006 and FDA 21 CFR 177.1660
Materials not in contact with process
Component part Material Product Configurator
Process connection 316L (1.4404/1.4435) Order code 110, option WDJ
Polycarbonate Order code 110, option WDG
Lock nut PA (black) Order code 620, option R7
Housing cover, valve plug PPSU
Design ring: PBT/PC
M12 housing covers 316L (1.4404/1.4435) Order code 40, option N
PPSU Design ring: PBT/PC
Housing 316L (1.4404/1.4435) Order code 110, option WDJ
Polycarbonate Order code 110, option WDG
Nameplate lasered onto housing -
Ground terminal (optional) 304 (1.4301) See Ex approval, order code 10 →  21
Protection cover (optional) Polycarbonate See Ex approval, order code 10 →  21
Order code 40, option U, V
Order code 40, option M
Endress+Hauser supplies DIN/EN process connections with threaded connection in stainless steel in accordance with AISI 316L (DIN/EN material number 1.4404 or 14435). In terms of their stability-temperature property, the materials 1.4404 and 1.4435 are grouped in EN 1092-1 table 18 under 13E0. The chemical composition of the two materials can be identical.
14 Endress+Hauser
Page 15
Nivector FTI26

Surface roughness

Operating concept for devices with IO-Link

IO-Link information

Sensor surface in contact with process: Ra ≤ 0.76 µm (30 µin), ordering information: Product Configurator order code for "Process connection" option "WDJ"

Operability

Operator-oriented menu structure for user-specific tasks
Quick and safe commissioning
Guided menus for applications
Reliable operation
Operation in the following languages: Via IO-Link: English
Efficient diagnostic behavior increases measurement availability
• Remedial measures
• Simulation options
IO-Link is a point-to-point connection for communication between the measuring device and an IO­Link master. The measuring device features an IO-Link communication interface type 2 with a second IO function on pin 4. This requires an IO-Link-compatible assembly (IO-Link master) for operation. The IO-Link communication interface enables direct access to the process and diagnostic data. It also provides the option of configuring the measuring device while in operation.
Physical layer, the measuring devices supports the following features:
• IO-Link specification: version 1.1
• IO-Link Smart Sensor Profile 2nd Edition
• SIO mode: yes
• Speed: COM2; 38.4 kBaud
• Minimum cycle time: 6 msec.
• Process data width: 16 bit
• IO-Link data storage: yes
• Block configuration: no

IO-Link download

http://www.endress.com/download
• Select "Software" as the media type.
• Select "Device Driver" as the software type. Select IO-Link (IODD).
• In the "Text Search" field enter the device name.
https://ioddfinder.io-link.com/
Search by – Manufacturer – Article number – Product type
Endress+Hauser 15
Page 16

Light signals (LEDs)

A
B
1
2
3
4
12
3
2b
3
1
2 3
1
2a
Nivector FTI26
 10 Position of LEDs on housing cover
A Housing cover with M12 plug, plastic B Housing cover with valve plug
There is no external signaling via LEDs on the metal housing cover (IP69). A connecting cable with an M12 plug and LED display can be ordered as an accessory if necessary. This cable has no red LED. See "Accessories".
Position LEDs Description of function
Green LED (gn)
1
Yellow LED
2
(ye)
Red LED (rd) Warning/Maintenance required
3
Lit: Measuring device is operational
In conjunction with IO-Link communication:
• lit: SIO mode
• flashing: Active communication, flash frequency
• flashes with increased luminosity: Device search (device identification), flash frequency
M12 plug LED 2a
Active only in conjunction with IO-Link communication.
LED 2b display of sensor status
Sensor is covered by medium.
M12 plug in conjunction with IO-Link communication: LED 2a switch status/switch output 2
Following customer adjustment: Sensor is covered by medium 1.
LED 2b switch status/switch output 1
Following customer adjustment: Sensor is covered by medium 2.
Valve plug: Indicates switch status
MAX mode (overfill protection): Sensor is not covered by medium MIN mode (dry-running protection): Sensor is covered by medium
flashing: Error remediable, e. g. invalid calibration
Fault/device failure
lit: Error not remediable, e. g. Electronics error Diagnostics and troubleshooting
A0036482

Device search

IO-Link communication: The Device search parameter is used to uniquely identify the device during installation.

Sensor check

IO-Link communication: The Sensor check parameter checks if the sensor system is functioning correctly. The sensor must not be covered and must be free of residue.

Medium calibration

Empty/full calibration are carried out with the test magnet or by means of IO-Link communication.
The threshold is defined automatically following calibration. The thresholds can also be adjusted manually in the case of IO-Link.

Function test

The test magnet is used to invert the current switch status.
The test magnet is included in the scope of delivery. It is also possible to cancel it →  20.
16 Endress+Hauser
Page 17
Nivector FTI26
N
Ser. no.:
Order code:
Ext. ord. cd.:
A0035882
 11 Position for test magnet on housing nameplate

Certificates and approvals

Currently available certificates and approvals can be called up via the product configurator.

CE mark

C-tick symbol

RoHS

RCM-Tick marking

EAC conformity

The measuring system is in conformity with the statutory requirements of the applicable EC Directives. These are listed in the corresponding EC Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.
The measuring system complies with EMC requirements of the "Australian Communications and Media Authority (ACMA)".
The measuring system complies with the substance restrictions of the Restriction on Hazardous Substances Directive 2011/65/EU (RoHS 2).
The supplied product or measuring system meets the ACMA (Australian Communications and Media Authority) requirements for network integrity, interoperability, performance characteristics as well as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.
A0029561
The measuring system meets the legal requirements of the applicable EAC guidelines. These are listed in the corresponding EAC Declaration of Conformity together with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the EAC mark.
Pressure equipment with allowable pressure ≤ 200 bar (2 900 psi)
Pressure instruments with a flange and threaded boss that do not have a pressurized housing do not fall within the scope of the Pressure Equipment Directive, irrespective of the maximum allowable pressure.
Reasons:
According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as "devices with an operational function and having pressure-bearing housings".
If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber of its own), there is no pressure accessory present within the meaning of the Directive.
Endress+Hauser 17
Page 18
Nivector FTI26
TYPE EL - CLASS I
xxx

Ex approval

Sanitary compatibility

The devices are certified for use in hazardous areas and the relevant safety instructions are provided in the separate "Safety Instructions" (XA01734F) document. Reference is made to this document on the nameplate.
You will find information on the available certificates in the supplementary documentation section →  21
The device has been developed for use in hygienic processes. The process-wetted materials meet the requirements stipulated in EU 1935/2004, 10/2011, 2023/2006 and FDA 21 CFR 177.2415 (only for order code for "Process connection", option "WDJ").
By affixing the 3-A symbol to the device, Endress+Hauser confirms compliance with the 3-A Sanitary Standard No. 74-xx and No. 50-xx.
The following certificate copies can be ordered with the device (optional):→  18
3-A
A0037165
EHEDG
• To avoid the risk of contamination, install the device in accordance with the design principles of EHEDG, Document 37 "Hygienic Design and Application for Sensors" and Document 16 "Hygienic Pipe Connections".
• Suitable connections and seals must be used in order to guarantee a hygienic design in accordance with the specifications of 3-A and EHEDG.
• Information on 3-A and EHEDG-approved weld-in adapters can be found in the "Weld-in adapter, process adapter and flanges" documentation, TI00426F/00/EN.

Manufacturer's Declaration

Hygiene approval
WDJ + PI
WDJ + RI
1)
EHEDG 3-A
Process connections Option
ISO228 G1" thread, 316L in conjunction with Tri­Clamp 2" process adapter
ISO228 G1" thread, 316L in conjunction with G1" weld-in adapter
1) See order code in Product Configurator
The following documents can be ordered with the device (optional):
• FDA conformity
• Regulation (EC) No. 1935/2004 on materials and articles intended to come into contact with food

Ordering information

Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
-> Select your country -> Click "Products" -> Select the product using the filters and search field -> Open product page -> The "Configure" button to the right of the product image opens the Product Configurator.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop
18 Endress+Hauser
Page 19
Nivector FTI26
58.6 (2.31) 64 (2.52)
41 (1.61)
60 (2.36)
58.6 (2.31)
A
B
41 (1.61)
77.4 (3.05)
22.8 (0.9)
36.8
(1.45)
!37.4 (1.47)
36.8
(1.45)
!37.4 (1.47)
22.8 (0.98)
77.4 (3.05)
46
A
B
46

Accessories

• Accessories can be ordered with the device (optional) or separately.
• The adapters are also available with inspection certificate 3.1 EN10204. For more information on process adapters and weld-in adapters, please refer to the supplementary documentation →  21 .

Adapter

Protector G 1½'', R 1½''

• For hygiene sector and hazardous areas
• Material: 316L (1.4404), seal: EPDM 70
• Weight: 265 g (9.347 oz.)
• Order number Tri-Clamp 2": 71395793
• Order number weld-in adapter G 1": 71395797
A0036229
A Tri-Clamp 2", order code 620, option RI B Weld-in adapter G 1", order code 620, option PI
G 1½'' R 1½''
Material PBT-GF PBT-GF
Weight 74 g (2.610 oz) 71 g (2.504 oz)
Order number 71395785 71395862
Order code 620, option: PA PB
A G 1½'' B R 1½''

Lock nut

• Material: PA
• Order number: 71395801
Endress+Hauser 19
A0035938
Page 20
Nivector FTI26
8 (0.31)
G 1"
1
2 (0.08)
41 mm
2 (0.08)
0.6 Nm
ye 1
ye 2
gn
27.5 (1.08)
40
(1.57)
³
~52.5 (2.07)
ø20
(0.8)
A0036041

Protection cover

Test magnet

Plug-in jack, connection adapter

• Material: PC
• Order number: 71395803
Order number: 71267011
Designation Order number Option
Cable, plug-in jack Engineering unit mm (in)
Example: M12 with LED
M12 IP69 with LED
• Elbowed 90°, terminated at one end
• 5 m (16 ft) PVC cable (orange)
• Body: PVC (transparent)
• Slotted nut 316L
M12 IP69 without LED
• Elbowed 90°, terminated at one end
• 5 m (16 ft) PVC cable (orange)
• Body: PVC (orange)
• Slotted nut 316L (1.4435)
M12 IP67 without LED
• Elbowed 90°
• 5 m (16 ft)PVC cable (gray)
• Slotted nut Cu Sn/Ni
• Body: PUR (blue)
M12 IP67 without LED
• Straight, self-terminated connection to M12 plug
• Slotted nut Cu Sn/Ni
• Body: PBT
52018763 RX
52024216 RW
52010285 RZ
52006263 R1
A0036434
1)
Wire colors for M12 plug: 1 = BN (brown), 2 = WT (white), 3 = BU (blue), 4 = BK (black)
1) See order code in Product Configurator
20 Endress+Hauser
Page 21
Nivector FTI26

Supplementary documentation

For an overview of the scope of the associated Technical Documentation, refer to the following:
W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate
Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate

Operating Instructions

Supplementary documentation

Certificates

• BA01830F → Nivector FTI26
• BA01832F → Nivector FTI26, IO-Link
• TI00426F/00/DE → Weld-in adapters, process adapters and flanges (overview)
• SD01622Z/00/YY → Weld-in adapter (assembly manual)
• SD00356F/00/EN→ Valve plug (assembly manual)
• SD02242F/00/A2 → Protector (Installation Instructions)
Approval Documentation code Order code 10, option:
ATEX II 1/3D Ex ta/tc IIIC T100°C Da/Dc CSA AEx/Ex ta/tc IIIC T100°C Da/Dc EAC Ex ta/tc IIIC T100°C Da/Dc X IECEx Ex ta/tc IIIC T100°C Da/Dc
XA01734F BO, CO, GO, IO

Registered trademarks

is a registered trademark of the IO-Link company group.
Endress+Hauser 21
Page 22
Page 23
Page 24
*71398859*
71398859
www.addresses.endress.com
Loading...