• Easy installation thanks to compact design - even in tight conditions or where
access is restricted.
• Also suitable for use in
– Food industry
– Hazardous atmospheres formed by combustible dust, zone 20
– Process temperatures of –20 to +80 °C (–4 to +176 °F).
Your benefits
• Onsite function check via LED indication
• Robust stainless steel housing, optionally available with M12x1 connector with
IP69 protection
• Easy and cost-effective commissioning: Precalibration in factory (plug and play)
Process temperature range ...................... 12
Process pressure range ......................... 12
Process fluid ................................ 12
Mechanical construction .................... 13
Connector ................................. 14
Weight ................................... 14
2Endress+Hauser
Page 3
Nivector FTI26
About this document
Document conventionsSymbols for certain types of information
SymbolMeaning
Permitted
Indicates procedures, processes or actions that are allowed.
Preferred
Indicates procedures, processes or actions that are preferred.
Tip
Indicates additional information.
Reference to page
Refers to the corresponding page number.
Symbols in graphics
SymbolMeaning
1, 2, 3 ...Item numbers
A, B, C, ...Views
Endress+Hauser3
Page 4
Function and system design
1
2
Nivector FTI26
Measuring principle
Measuring system
The sensor surface of the Nivector evaluates the different dielectric values of air and bulk solids. If
the bulk solids come into contact with the sensor surface, the electronics change the switch status.
The Nivector can be switched to either minimum of maximum fail-safe mode, ensuring quiescent
current operation in all applications. The switch status is indicated by an LED. A guard electrode
eliminates interference factors due to the vessel wall or possible buildup, for example.
Depending on the fail-safe mode selected and the level, the Nivector switches and signals in the
following cases:
• When point level is reached
• In the event of a problem
• In the event of a power failure (electrical switch is locked)
The measuring system comprises a Nivector point level switch, e. g. for connecting to PLCs or an IOLink master as per DIN EN 61131-9. A suitable miniature contactor or a solenoid valve can be
connected directly to the point level switch.
1Application examples
1Overfill protection or upper level detection (MAX)
2Dry-running protection or lower level detection (MIN)
System integration
For devices with IO-Link, an IO-DD is available in the Downloads area of the Endress+Hauser website
→ 15.
A0035880
4Endress+Hauser
Page 5
Nivector FTI26
Input
Measured variable
Measuring range
Switch output
Level (point level switch)
The change in medium capacitance is detected by the electrode in contact with the process.
Bulk solids, e. g. foodstuffs in powder form
• Dielectric constant (Dk) > 1.3
• Grain size < 10 mm
Output
Designation
• 3-wire DC-PNP
Positive voltage signal at the switch output of the electronics
• 2 DC-PNP outputs, switched using XOR operation
• 200 mA connectable load (short-circuit proof)
Devices with IO-Link
• 3- or 4-wire DC-PNP
• 2 DC-PNP outputs, freely configurable
• 1 switch output active: 200 mA
• Both switch outputs active: Connectable load of 105 mA each (short-circuit proof)
1)Product Configurator, order code for "Power supply; output"
2)Unlike the IO-Link standard, the SIO mode supports 200 mA.
2)
connectable load (short-circuit proof)
Option
4
7
1)
• Safety-related switching: MIN or MAX point level. The electrical switch opens if the point level is
reached or if faults or a power outage occur.
– Maximum point level detection (MAX): e. g. for overfill protection
The device keeps the electrical switch closed as long as the sensor is not yet covered by medium.
This is also the case for devices with IO-Link if the measured value is inside the process window.
– Minimum point level detection (MIN): e. g. for dry-running protection
The device keeps the electrical switch closed as long as the sensor is covered by medium. This is
also the case for devices with IO-Link if the measured value is outside the process window.
• Residual voltage: < 3 V
• Residual current: < 100 µA
Endress+Hauser5
Page 6
Power supply
0.5A
L– L+
2
1
3
4
K
0.5A
L–
L+
2
1
3
4
K
1
21
2
1
41
4
L–
L+
C/Q1
2
1
3
4
SIO
IO-Link
0.5 A
K1
Q2
Nivector FTI26
Supply voltage
Power consumption
Current consumption
Electrical connection
12 to 30 V DC
IO-Link communication is guaranteed only if the supply voltage is at least 18 V.
< 1.2 W (at max. load:200 mA)
< 20 mA
Voltage source: Non-hazardous contact voltage or Class 2 circuit (North America). The device must
be operated with a fine-wire fuse 500 mA (slow-blow).
Depending on the evaluation of the switch outputs, the device works in the MAX (maximum point
level detection) or MIN (minimum point level detection) modes.
M12 plug
Electrical connectionMode of operation
M12 plugMAXMIN
SymbolsKDescription
Yellow LED (ye) lit
Yellow LED (ye) not lit
External load
Devices with IO-Link
• IO-Link: Communication on C/Q1; switch mode on Q2.
• SIO mode: If there is no communication, the device switches to the SIO mode = standard IO
mode.
The factory-set functions for the MAX and MIN modes can be changed via IO-Link.
Electrical connectionIO-Link with one switch output
M12 plug
1Supply voltage +
2DC-PNP (Q2)
3Supply voltage 4C/Q1 (IO-Link communication or SIO mode)
1)
A0034411
1)Product Configurator, order code for "Power supply; output", option 7
6Endress+Hauser
Page 7
Nivector FTI26
0.5A
L–L+
2
1
3
4
K2
Q1
K1
Q2
0.5A
L–L+
2
1
3
4
K1
K2
1
2
1
4
4
1
12
21
41
Electrical connectionBoth switch outputs active simultaneously
M12 plug
1Supply voltage +
2DC-PNP (Q2)
3Supply voltage 4DC-PNP (Q1)
1)Depending on configuration
2)Current consumption with two outputs connected: < 25 mA
1) 2)
A0035998
Function monitoring
In the order configuration: With two-channel evaluation, functional monitoring of the sensor is also
possible in addition to level monitoring, provided that no other monitoring option has been
configured via IO-Link.
When both outputs are connected, the MIN and MAX outputs assume opposite states (XOR) when
the device is operating fault-free. In the event of an alarm condition or a line break, both outputs are
de-energized.
Connection for function monitoring using XOR operation
Sensor covered
Sensor
uncovered
Fault
A0022917
Symbols
K1/K2
Description
LED lit
LED not lit
Fault or warning
External load
Yellow LED
(ye)
Red LED
(rd)
Endress+Hauser7
Page 8
Nivector FTI26
1
3
0.5A
L–
L+
2
K
+
–
L–
L+
3
0.5A
1
2
K
+
–
3
23
2
2323
Valve plug
Depending on the assignment of the connector, the device works in either the MAX or MIN mode.
Electrical connectionMode of operation
Valve plugMAXMIN
A0022900
SymbolsKDescription
Yellow LED (ye) not lit
Yellow LED (ye) lit
External load
Cable specification
Length of connecting cable
Overvoltage protection
Reference operating
conditions
Switch-on behavior
• M12 plug: IEC 60947-5-2
• Valve plug
– Cable cross-section: Max.1.5 mm2 (16 AWG)
– Ø3.5 to 6.5 mm (0.14 to 0.26 in)
• Max. 25 Ω/core, total capacity < 100 nF
• IO-Link communication: < 10 nF
Overvoltage category II
Performance characteristics
Accuracy in accordance with DIN EN 61298-1 based on 100% (factory adjustment)
• Non-repeatability: ± 1 %
• Uncertainty, absolute: ± 2.5 %
• Hysteresis: + 0.5 % ± 0.5 %
Horizontal orientation:
• Ambient temperature: 20 °C (68 °F) ±5 °C
• Medium temperature: 20 °C (68 °F) ±5 °C
• Process pressure: 1 bar abs. (14.5 psi)
• Medium: Sliding earthed metal plate in front of sensor.
< 2 s
Influence of ambient
Maximum 0.1 %/K
temperature
Switch-on delay
Switching delay
< 2 s until correct switch status is set. Prior to that, the switch outputs are in a blocked state.
• 0.5 s when sensor is covered
• 1.0 s when sensor is uncovered
• IO-Link communication: 0.3 to 60 s configurable
• Can be ordered as option: 0.3 s; 1.5 s or 5 s (when sensor is covered or uncovered)
1)See Product Configurator, order code 570, option HS
8Endress+Hauser
1)
Page 9
Nivector FTI26
≥20 (0.8)
G 1"
≥20 (0.8)
G 1"
≥20 (0.8)
G 1"
14 (0.55)
G 1"
Installation
Mounting location
Installation instructions
Lateral mounting in bulk solids silos, indoors or outdoors, e. g. in silo
For installation in metallic or non-metallic bulk solids silos, follow the EMC
guidelines→ 11.
• Engineering unit mm (in)
• Sensor surface ≥ 20 mm (0.79 in) projecting into silo (when installing with weld-in adapter
20 mm (0.79 in)
• Silo wall thickness < 35 mm (1.38 in) or welding socket G 1" < 50 mm (1.97)
Examples
A0035881
2Standard installation with external G 1" threaded adapter
3Where buildup occurs on the silo wall with internal G 1" threaded adapter
4Bore hole in silo wall with lock nuts, can be ordered as an accessory → 19
5Installation with weld-in adapter, can be ordered as an accessory → 19
A0036360
A0036359
A0036362
Endress+Hauser9
Page 10
Nivector FTI26
≥20 (0.8)
G 1½"
≥20 (0.8)
G 1"
6Installation with Tri-Clamp and NA Connect provided by customer, can be ordered as an accessory
→ 19
Installation with protector
• Protection of point level switch against damage by particularly abrasive or coarse product
• Outflow protection in silo for functional testing when silo is full
7Installation with protector, can be ordered as an accessory → 19
A0036363
A0036361
Installation with protection cover
• Installation with protection cover against impact effects or
• in hazardous area
Please also ensure compliance with the corresponding national standards and regulations and the
Safety Instructions or Installation or Control Drawings → 21
• Fit the protection cover before the device is put into operation.
A0036433
8Installation with protection cover, included in scope of delivery for hazardous areas or can be ordered as
an accessory → 19
10Endress+Hauser
Page 11
Nivector FTI26
90 (194)
80 (176)
70 (158)
60 (140)
50 (122)
40 (104)
30 (86)
20 (68)
10 (50)
0 (32)
1
T
T
40 (104)
0 (32)
10 (50)
20 (68)
30 (86)50 (122)90 (194)
80 (176)
70 (158)
60 (140)
p
a
Ambient temperature range
Environment
Storage temperature
Relative humidity
Climate class
Altitude
Degree of protection
Shock resistance
Vibration resistance
Cleaning
Electromagnetic
compatibility
A0036858
1)Ex devices
Tp) Process temperature = °C (°F)
Ta) Ambient temperature = °C (°F)
–25 to +85 °C (–13 to +185 °F)
Pressure: 1 bar abs. (14.5 psi)
0 to 100 %
DIN EN 60068-2-38/IEC 68-2-38: Test Z/AD
Up to 2000 m (6600 ft) above sea level
• IP65/67 NEMA Type 4X Enclosure (M12 plug for plastic housing cover)
• IP66/68/69 NEMA Type 4X/6P Enclosure (M12 plug for metal housing cover)
• IP65 NEMA Type 4x Enclosure (ISO4400 M16/NPT ½" valve plug for plastic housing cover)
In accordance with EA inspection, prEN 60068-2-27:2007: a = 300 m/s 2 = 30 g, 3 planes x 2
directions x 3 shocks x 18 ms
In accordance with Fh inspection, EN 60068-2-64:2008: a(RMS) = 50 m/s2, f = 5 to 2000 Hz, t = 3
planes x 8 h
Resistant to typical cleaning agents from the outside. Passed Ecolab test.
The electromagnetic compatibility requirements outlined in the IEC/EN 61326 series for "industrial
environments" are fulfilled when the device is installed in metallic vessel or metallic pipes. Emission
requirements for class B equipment are met. For details, refer to the Declaration of Conformity.
If the device is installed in plastic structures, its function may be influenced by strong
electromagnetic fields. Emission requirements for class A equipment are met (only for use in
"industrial environments").
Reverse polarity protection
Endress+Hauser11
Integrated; no damage in the event of reverse polarity or short-circuit
Page 12
Nivector FTI26
Short-circuit protection
Process temperature range
Process pressure range
Process fluid
• Overload protection/short-circuit protection at I > 200 mA
• IO-Link communication: 105 mA each if both switch outputs are active
Intelligent monitoring: Testing for overload at intervals of approx. 1.5 s; normal operation resumes
once the overload/short-circuit has been rectified.
Process
–20 to +80 °C (–4 to +176 °F)
For Ex devices: –20 to +75 °C (–4 to +167 °F)
–1 to +6 bar (–14.5 to +87 psi)
Powdery and fine-grained bulk solids
• Grain size < 10 mm
• Dielectric constant 1.3
• Default values: εr > 1.6 with protector, εr > 2.0 without protector
12Endress+Hauser
Page 13
Nivector FTI26
A
BC
H1
H2
H3
H4
H5
!35
(1.38)
G1"G1"
H5
H1
H2
H3
H4
H1
H2
H3
H4
G1"
H5
!31.5
(1.24)
!31.5
(1.24)
42.5 (1.7)
Mechanical construction
Exact dimensions are available in the Product Configurator on the Endress+Hauser website:
www.endress.com → Product finder → On the product page, click the "Configure" button to the
right of the product photo.
Engineering unit mm (in)
A0036387
ANivector FTI26 plastic with M12 plug
BNivector FTI26 stainless steel with M12 plug, with optional ground terminal
CNivector FTI26 stainless steel with valve plug
Height
measurement
H1Housing cover20.5 (0.81)16 (0.36)
H2Housing43.6 (1.72)
H3Process connection52 (2.05)
H4Sensor20 (0.79)
H5Nivector FTI26 overall
DesignationABC
136 (5.35)131.2 (5.17)
dimensions
Additional accessories for hygiene sector and hazardous areas: weld-in adapter G 1", Tri-Clamp
2", protection cover→ 19
Endress+Hauser13
Page 14
Nivector FTI26
40 (1.6)
51.5 (2.0)
Connector
Weight
Materials
Dimensions mm (in)
Connection plug with PPSU plastic housing cover
9Valve plug M16, NPT ½"
• Plastic with M12 plug: 118 g (4.162 oz)
• Plastic with valve plug120 g (4.232 oz):
• Stainless steel with M12 plug240 g (8.465 oz):
• Stainless steel with valve plug: 243 g (8.465 oz)
• Stainless steel with M12 plug and protection cover: 288 g (10.158 oz)
Wetted materials
Component partMaterialProduct Configurator
Sensor316L (1.4404), ECTFE
PolycarbonateOrder code 110, option WDG
Protector G 1½"Material PBT-GF
Protector R 1½"Order code 620, option PB
O-ring EPDM
1)
2)
Order code 110, option WDJ
Order code 620, option PA
A0021859
1)The material ECTFE meets the requirements of EU 1935/2004, 10/2011, 2023/2006 and
FDA 21 CFR 177.1380
2)The material meets the requirements of EU 1935/2004, 10/2011, 2023/2006 and FDA 21 CFR 177.1660
Materials not in contact with process
Component partMaterialProduct Configurator
Process connection316L (1.4404/1.4435)Order code 110, option WDJ
PolycarbonateOrder code 110, option WDG
Lock nutPA (black)Order code 620, option R7
Housing cover, valve plugPPSU
Design ring: PBT/PC
M12 housing covers316L (1.4404/1.4435)Order code 40, option N
Ground terminal (optional)304 (1.4301)See Ex approval, order code 10 → 21
Protection cover (optional)PolycarbonateSee Ex approval, order code 10 → 21
Order code 40, option U, V
Order code 40, option M
Endress+Hauser supplies DIN/EN process connections with threaded connection in stainless
steel in accordance with AISI 316L (DIN/EN material number 1.4404 or 14435). In terms of
their stability-temperature property, the materials 1.4404 and 1.4435 are grouped in EN
1092-1 table 18 under 13E0. The chemical composition of the two materials can be identical.
14Endress+Hauser
Page 15
Nivector FTI26
Surface roughness
Operating concept for
devices with IO-Link
IO-Link information
Sensor surface in contact with process: Ra ≤ 0.76 µm (30 µin), ordering information: Product
Configurator order code for "Process connection" option "WDJ"
Operability
Operator-oriented menu structure for user-specific tasks
Quick and safe commissioning
Guided menus for applications
Reliable operation
Operation in the following languages:
Via IO-Link: English
IO-Link is a point-to-point connection for communication between the measuring device and an IOLink master. The measuring device features an IO-Link communication interface type 2 with a
second IO function on pin 4. This requires an IO-Link-compatible assembly (IO-Link master) for
operation. The IO-Link communication interface enables direct access to the process and diagnostic
data. It also provides the option of configuring the measuring device while in operation.
Physical layer, the measuring devices supports the following features:
• IO-Link specification: version 1.1
• IO-Link Smart Sensor Profile 2nd Edition
• SIO mode: yes
• Speed: COM2; 38.4 kBaud
• Minimum cycle time: 6 msec.
• Process data width: 16 bit
• IO-Link data storage: yes
• Block configuration: no
IO-Link download
http://www.endress.com/download
• Select "Software" as the media type.
• Select "Device Driver" as the software type.
Select IO-Link (IODD).
• In the "Text Search" field enter the device name.
https://ioddfinder.io-link.com/
Search by
– Manufacturer
– Article number
– Product type
Endress+Hauser15
Page 16
Light signals (LEDs)
A
B
1
2
3
4
12
3
2b
3
1
2
3
1
2a
Nivector FTI26
10Position of LEDs on housing cover
AHousing cover with M12 plug, plastic
BHousing cover with valve plug
There is no external signaling via LEDs on the metal housing cover (IP69). A connecting cable
with an M12 plug and LED display can be ordered as an accessory if necessary. This cable has
no red LED. See "Accessories".
Position LEDsDescription of function
Green LED
(gn)
1
Yellow LED
2
(ye)
Red LED (rd)Warning/Maintenance required
3
Lit: Measuring device is operational
In conjunction with IO-Link communication:
• lit: SIO mode
• flashing: Active communication, flash frequency
• flashes with increased luminosity: Device search (device identification), flash
frequency
M12 plug
LED 2a
Active only in conjunction with IO-Link communication.
LED 2b display of sensor status
Sensor is covered by medium.
M12 plug in conjunction with IO-Link communication:
LED 2a switch status/switch output 2
Following customer adjustment: Sensor is covered by medium 1.
LED 2b switch status/switch output 1
Following customer adjustment: Sensor is covered by medium 2.
Valve plug: Indicates switch status
MAX mode (overfill protection): Sensor is not covered by medium
MIN mode (dry-running protection): Sensor is covered by medium
flashing: Error remediable, e. g. invalid calibration
Fault/device failure
lit: Error not remediable, e. g. Electronics error
Diagnostics and troubleshooting
A0036482
Device search
IO-Link communication: The Device search parameter is used to uniquely identify the device during
installation.
Sensor check
IO-Link communication: The Sensor check parameter checks if the sensor system is functioning
correctly. The sensor must not be covered and must be free of residue.
Medium calibration
Empty/full calibration are carried out with the test magnet or by means of IO-Link communication.
The threshold is defined automatically following calibration. The thresholds can also be adjusted
manually in the case of IO-Link.
Function test
The test magnet is used to invert the current switch status.
The test magnet is included in the scope of delivery. It is also possible to cancel it → 20.
16Endress+Hauser
Page 17
Nivector FTI26
N
Ser. no.:
Order code:
Ext. ord. cd.:
A0035882
11Position for test magnet on housing nameplate
Certificates and approvals
Currently available certificates and approvals can be called up via the product configurator.
CE mark
C-tick symbol
RoHS
RCM-Tick marking
EAC conformity
The measuring system is in conformity with the statutory requirements of the applicable EC
Directives. These are listed in the corresponding EC Declaration of Conformity along with the
standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE
mark.
The measuring system complies with EMC requirements of the "Australian Communications and
Media Authority (ACMA)".
The measuring system complies with the substance restrictions of the Restriction on Hazardous
Substances Directive 2011/65/EU (RoHS 2).
The supplied product or measuring system meets the ACMA (Australian Communications and Media
Authority) requirements for network integrity, interoperability, performance characteristics as well
as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic
compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.
A0029561
The measuring system meets the legal requirements of the applicable EAC guidelines. These are
listed in the corresponding EAC Declaration of Conformity together with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the EAC mark.
Pressure equipment with
allowable pressure
≤ 200 bar (2900 psi)
Pressure instruments with a flange and threaded boss that do not have a pressurized housing do not
fall within the scope of the Pressure Equipment Directive, irrespective of the maximum allowable
pressure.
Reasons:
According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as
"devices with an operational function and having pressure-bearing housings".
If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber
of its own), there is no pressure accessory present within the meaning of the Directive.
Endress+Hauser17
Page 18
Nivector FTI26
TYPE EL - CLASS I
xxx
Ex approval
Sanitary compatibility
The devices are certified for use in hazardous areas and the relevant safety instructions are provided
in the separate "Safety Instructions" (XA01734F) document. Reference is made to this document on
the nameplate.
You will find information on the available certificates in the supplementary documentation
section → 21
The device has been developed for use in hygienic processes. The process-wetted materials meet the
requirements stipulated in EU 1935/2004, 10/2011, 2023/2006 and FDA 21 CFR 177.2415 (only
for order code for "Process connection", option "WDJ").
By affixing the 3-A symbol to the device, Endress+Hauser confirms compliance with the 3-A
Sanitary Standard No. 74-xx and No. 50-xx.
The following certificate copies can be ordered with the device (optional):→ 18
3-A
A0037165
EHEDG
• To avoid the risk of contamination, install the device in accordance with the design principles of
EHEDG, Document 37 "Hygienic Design and Application for Sensors" and Document 16 "Hygienic
Pipe Connections".
• Suitable connections and seals must be used in order to guarantee a hygienic design in accordance
with the specifications of 3-A and EHEDG.
• Information on 3-A and EHEDG-approved weld-in adapters can be found in the "Weld-in adapter,
process adapter and flanges" documentation, TI00426F/00/EN.
Manufacturer's Declaration
Hygiene approval
WDJ + PI
WDJ + RI
1)
EHEDG3-A
Process connectionsOption
ISO228 G1" thread, 316L in conjunction with TriClamp 2" process adapter
ISO228 G1" thread, 316L in conjunction with G1"
weld-in adapter
1)See order code in Product Configurator
The following documents can be ordered with the device (optional):
• FDA conformity
• Regulation (EC) No. 1935/2004 on materials and articles intended to come into contact with food
Ordering information
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
-> Select your country -> Click "Products" -> Select the product using the filters and search field ->
Open product page -> The "Configure" button to the right of the product image opens the Product
Configurator.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop
18Endress+Hauser
Page 19
Nivector FTI26
58.6 (2.31)
64 (2.52)
41 (1.61)
60 (2.36)
58.6 (2.31)
A
B
41 (1.61)
77.4 (3.05)
22.8 (0.9)
36.8
(1.45)
!37.4
(1.47)
36.8
(1.45)
!37.4
(1.47)
22.8 (0.98)
77.4 (3.05)
46
A
B
46
Accessories
• Accessories can be ordered with the device (optional) or separately.
• The adapters are also available with inspection certificate 3.1 EN10204. For more information on
process adapters and weld-in adapters, please refer to the supplementary documentation
→ 21 .
Adapter
Protector G 1½'', R 1½''
• For hygiene sector and hazardous areas
• Material: 316L (1.4404), seal: EPDM 70
• Weight: 265 g (9.347 oz.)
• Order number Tri-Clamp 2": 71395793
• Order number weld-in adapter G 1": 71395797
A0036229
ATri-Clamp 2", order code 620, option RI
BWeld-in adapter G 1", order code 620, option PI
G 1½''R 1½''
MaterialPBT-GFPBT-GF
Weight74 g (2.610 oz)71 g (2.504 oz)
Order number7139578571395862
Order code 620, option:PAPB
AG 1½''
BR 1½''
Lock nut
• Material: PA
• Order number: 71395801
Endress+Hauser19
A0035938
Page 20
Nivector FTI26
8 (0.31)
G 1"
1
2 (0.08)
41 mm
2 (0.08)
0.6 Nm
ye 1
ye 2
gn
27.5
(1.08)
40
(1.57)
³
~52.5 (2.07)
ø20
(0.8)
A0036041
Protection cover
Test magnet
Plug-in jack, connection
adapter
• Material: PC
• Order number: 71395803
Order number: 71267011
DesignationOrder number Option
Cable, plug-in jack
Engineering unit mm (in)
Example: M12 with LED
M12 IP69 with LED
• Elbowed 90°, terminated at one end
• 5 m (16 ft) PVC cable (orange)
• Body: PVC (transparent)
• Slotted nut 316L
M12 IP69 without LED
• Elbowed 90°, terminated at one end
• 5 m (16 ft) PVC cable (orange)
• Body: PVC (orange)
• Slotted nut 316L (1.4435)
M12 IP67 without LED
• Elbowed 90°
• 5 m (16 ft)PVC cable (gray)
• Slotted nut Cu Sn/Ni
• Body: PUR (blue)
M12 IP67 without LED
• Straight, self-terminated connection
to M12 plug
• Slotted nut Cu Sn/Ni
• Body: PBT
52018763RX
52024216RW
52010285RZ
52006263R1
A0036434
1)
Wire colors for M12 plug: 1 = BN (brown), 2 = WT (white), 3 = BU (blue), 4 = BK (black)
1)See order code in Product Configurator
20Endress+Hauser
Page 21
Nivector FTI26
Supplementary documentation
For an overview of the scope of the associated Technical Documentation, refer to the following:
• W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from
nameplate
• Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D
matrix code (QR code) on the nameplate
Operating Instructions
Supplementary
documentation
Certificates
• BA01830F → Nivector FTI26
• BA01832F → Nivector FTI26, IO-Link
• TI00426F/00/DE → Weld-in adapters, process adapters and flanges (overview)