Memocheck CYP02D /
Memocheck Sim CYP03D
Testing tools for analysis measuring points
Simulation of sensors with Memosens Technology
Application
• Chemicals and process engineering
• Food, pharmaceutical industry and biotechnology
• Water and wastewater treatment
• Hazardous areas
Your benefits
• Increased plant safety thanks to complete sensor and error simulation
• Easy, quick and reliable sensor simulation with user-definable measured values for
CYP03D and fixed values for CYP02D
• Error simulation
• Verification of all parameters: pH (glass and ISFET), ORP, conductivity (conductive
and toroidal), dissolved oxygen (amperometric and optical), chlorine, turbidity and
nitrate
• High degree of flexibility when commissioning the measuring point
• Utmost reliability owing to Memosens Technology:
– No contact corrosion
– Completely watertight
– No interference from external potential thanks to galvanic isolation of simulator
and transmitter

Function and system design
Memocheck CYP02D / Memocheck Sim CYP03D
Simulation setup in nonhazardous areas
Sensor simulation in a complete measuring system consists of:
• Memocheck CYP02D or Memocheck Sim CYP03D
• Transmitter with Memosens Technology, e. g. Liquiline M CM42 or Liquiline CM44x
• Memosens data cable CYK10
A0025995
1 Measuring system with Memocheck Sim CYP03D
1 Transmitter Liquiline CM44x
2 Memosens data cable CYK10
3 Memocheck Sim CYP03D
2 Measuring system with Memocheck CYP02D
1 Liquiline M CM42 transmitter
2 Memosens data cable CYK10
3 Memocheck CYP02D
A0025994
2 Endress+Hauser

Memocheck CYP02D / Memocheck Sim CYP03D
II 2G
II 1G
II 3G
Ex ia
Zone 1
Zone 0
Zone 2
CYK10
CYP03D
not permitted
only with ATEXApproval
Simulation setup in
hazardous areas
Sensor simulation in a complete measuring system consists of:
• Memocheck Sim CYP03D
• Transmitter with Memosens Technology and Ex approval, e. g. Liquiline M CM42
• Memosens data cable CYK10
A0026198-EN
3 Operation in hazardous areas
Endress+Hauser 3

Performance characteristics
Memocheck CYP02D / Memocheck Sim CYP03D
Memocheck CYP02D
simulation values
Memocheck CYP02D consists of two interconnected sensor plug-in heads which are independent of
one another, and which each supply one specific parameter. You can simulate the following values
depending on your order:
Simulation values output for pH glass and pH ISFET
Fixed simulation
value
pH glass 4 25 ˚C (77 ˚F)
pH ISFET 7 60 ˚C (140 ˚F)
Temperature
Simulation values output for pH glass and pH glass
Fixed simulation
value
pH glass 4 25 ˚C (77 ˚F)
pH glass 7 60 ˚C (140 ˚F)
Temperature
Simulation values output for pH glass and ORP
Fixed simulation
value
pH glass 4 25 ˚C (77 ˚F)
ORP potential 750 mV 90 ˚C (194 ˚F)
Temperature
Simulation values output for pH glass and oxygen
Fixed simulation
value
pH glass 4 25 ˚C (77 ˚F)
Oxygen 60 nA
1) Sensor current
1)
Temperature
60 ˚C (140 ˚F)
Simulation values output for pH glass and conductive measurement of conductivity
Fixed simulation
value
pH glass 4 25 ˚C (77 ˚F)
Conductivity 20 µS/cm 60 ˚C (140 ˚F)
Temperature
Simulation values output for pH glass and chlorine
Fixed simulation
value
pH glass 4 25 ˚C (77 ˚F)
Chlorine 60 nA
1) Sensor current
1)
Temperature
25 ˚C (77 ˚F)
The data listed above are displayed on the transmitters.
Memocheck CYP02D is maintenance-free.
4 Endress+Hauser