Modular design — simple
to install and operate; allows
incremental cost-effective
system growth
n
Single point adjustment — no
tools required to change settings
and make adjustments; MCA
controls up to 168 rectifiers
n
LMS1000 monitoring with a
single plug in card — includes
SNMP and Web interface
n
Remote access — options allow
users to view, control and interact
with the system using an Ethernet
(Telnet, web pages, SNMP or TL1),
modem or RS 232
n
Plug’n’play — add rectifiers
without changing the settings and
making adjustments; no system
interruption
n
High density — compact design
takes up less floor space; houses
(24) 5800 watt rectifiers per
bay, distribution bays are rated
for 6000 amps in continuous
operation.
n
Efficiency — industry leading
3-phase rectifier; 93% peak,
PowerShare — allows the reuse
of existing equipment
with NetSure
n
Safety compliance — NEBS
Level 3 compliance (pending
3rd party testing); UL Listed
to UL subject 1801
™
801
5,800 watt rectifiers from Emerson
Network Power provide up to 110 amps
each. With 24 units per bay, these
rectifiers provide up to a 2,640 amp
output in a 24.375" x 30" footprint.
Description
The modular NetSure™ 801 power system
with 5800 watt rectifiers provides up
to 16,800 amps of power for -48 volt
systems. The basic components of the
system include 2640 amp power bays
which house the rectifiers and MCA
chassis, and 6000 amp distribution
bays. The cabled architecture allows the
placement of the bays anywhere the user
desires without regard to any specific
order. This also makes it more user friendly
in applications where existing obstacles,
such as support columns, need to be
accommodated. The total plant size is
defined by the maximum capacity of the
Main Battery Termination Bars (MBTB).
™
The NetSure
a powerful, microprocessor-based meter,
control and alarm system capable of
monitoring and controlling up to 168
rectifiers. The MCA provides a 4 line,
801 power system contains
40-character alphanumeric display, which
can be activated at the touch of a keypad.
Each rectifier bay can accommodate up
to 24 plug’n’play rectifiers, which are
controlled by the MCA. Additional bays can
be added as load requirements increase.
™
The NetSure
6000 amp modular distribution bays.
Each bay can be configured with up to
70 positions of fuses and circuit breakers
from 1-800 amps. Multiple bays may be
used to support load levels in excess of
16,800 amps. Contact an Emerson
application expert at 1-800-800-1280.
801 power system offers
Application
The NetSure™ 801 system is ideal for
wireline, wireless and data center applications such as switch sites, co-location,
MTSO and data processing centers.
2
Page 3
NetSure™ 801 System Elements
12
3
4
5
6
7
7
7
7
Main Power Bay
1
(Individual Feed, No Breakers)
Distribution Bay
2
AC Panel
3
(Dual Feed with Breakers)
MCA
4
Rectifiers
5
Bullet Fuse/Breaker Panel (Optional)
6
(4) 1500 Amp Fuse/Breaker
7
Distribution Buses
3
Page 4
The NetSure™ platform is globally
renowned with over 500k units deployed
and an unmatched reliability of less than
0.5% failure rate (200 years MTBF).
Modules & Options
Distribution Bay with Fuses
and Breakers Installed
AC Input
Two types of AC input are offered: dual
feed or twin feed. With the dual feed
option, two sources of AC are brought
into the termination panels. The AC is
internally distributed to the individual
rectifiers by 12 on-board circuit breakers
and the rectifiers are divided evenly
between sources. With the twin feed
option, each pair of rectifiers is sourced
separately from a customer provided
PDSC. This enables existing AC infrastructure to be used for 200 amp
rectifiers. If individual rectifier feeds are
required, simply remove the factoryinstalled jumpers. Conduit sizes up
to 2" can be accommodated.
Distribution
The NetSure
modular. There are a total of 48 distribution positions for GJ type circuit breakers
as well as an optional 24-position bullet
nose panel. In addition to E-Trip and E/M
Circuit breakers from 1 to 800 amps, the
system will accommodate TPS/TLS and
TPL fuses ranging from 1 to 800 amps.
Each GJ circuit breaker and TPL fuse is
individually monitored.
The system can also be expanded with
additional 6000 amp bays that do not
need to be adjacent to each other. The
only bay-to-bay connection required is
the CAN bus control cable. The power
feeds are cabled from the MBTBs.
Distribution device options include 1 to 250
amp plug-in circuit breakers, 3 to 100 amp
TPS/TLS-style fuses in plug-in holders, 100
to 800 amp GJ/218-style circuit breakers
and 70 to 800 amp TPL-style fuses.
™
801 distribution bay is
DC Output Termination Panel
4
Page 5
The NetSure
™
801 power system’s extensive monitoring
capabilities, easy configuration and maintenance are
all backed by the resources and quality reputation of a
MCA (Meter, Control & Alarm)
Emerson Network Power —
nationwide service organization.
Monitoring/Control
The MCA provides a single point of
adjustment for such features as float
voltage, test/equalize voltage, high
voltage shut-down and current limit for
all rectifiers in the entire power system.
The MCA provides local indicators and
the ability to transmit various alarm
conditions, system measurements and
system settings. All measurements and
adjustments can be performed locally via
the alphanumeric display on the front of
the MCA panel or remotely using the
optional LMS1000 monitor.
The MCA provides local indicators and the
ability to transmit various alarm conditions
such as rectifier failure, high voltage
Hybrid Applications
™
The NetSure
801 power system is designed to operate in conjunction with
existing equipment. Leverage our patented PowerShare technology to deploy a
true hybrid power plant by reusing existing power and/or distribution. Alarming
™
and telemetry are centralized within the NetSure
801 providing a single point of
contact. PowerShare offers significant cost savings through the reuse of existing
equipment already onsite.
shutdown and AC failure. Alarm relays are
programmable and will respond to SNMP
gets and send traps when combined with
the SNMP option. Remote communication
is provided using an Ethernet connection
(HTTP web browser, Telnet or SNMP),
modem or RS-232 interface.
R48-5800 Rectifier
Rectifier
The modular R48-5800 is a high frequency
rectifier designed with the latest patented
DSP (Digital Signaling Processing)
switch-mode technology. DSP reduces
cost by optimizing system operation and
requiring fewer components. System
configuration is easily accomplished with
these plug’n’play rectifiers. Rectifiers are
simply added to an existing rectifier bay or
newly added power bay to increase
capacity — no adjustments or setup are
™
required. NetSure
801 power systems
accommodate up to 264 rectifiers, which
provide load power and battery recharge
current. The rectifiers are monitored and
controlled by the MCA. The R48-5800
rectifiers enable the power plant to easily
grow to meet specific application needs.
Rectifier Bay
™
The NetSure
801 rectifiers are housed in
modular power bays that accommodate
24 rectifiers each. The rectifier bays are 7'
high x 24.375" wide x 30" deep. System
capacity can be easily expanded with
additional bays.
5
Page 6
NetSure™ 801 nleb – System Specifications
System Features
Nominal System Voltage -48VDC (-47 to -58 VDC)
Control Microprocessor (MCA)
Rated Output Capacity
System 16,800 amps (higher capacity configurations are available)
Power Bay 2640 amps
Distribution Bay6000 amps
Rectifier 5800 watt rectifier (R48-5800)
Distribution Panel 1500 amps (4 per bay)
Physical Characteristics
Framework Type Box frame
Mounting (H x W x D)Power Bay – 7' x 24.375" x 30"
Distribution Bay – 7' x 30" x 30"
Access Front and back
Environmental
Operating Temperature -32°F to 104°F (-0°C to 40°C) continuous operation
Storage -40°F to 185°F (-40°C to 85°C)
Humidity 0% to 95% relative humidity, non-condensing
Ventilation Fan-cooled front to rear
EMI/RFI Suppression Conforms to FCC rules Part 15, Subpart B, Class A and EN55022 Class A,
Safety Compliance UL Listed 1801, cUL, NEBS Level 3 (pending)
R48-5800 Rectifier – General Specifications*
Status / Alarm Indicators and Monitoring
Visual Indicators Status
Normal operation
Alarm
Rectifier failure alarm
Fan failure alarm
Status Settings The MCA controller establishes all rectifier settings
Physical Characteristics
Mounting Plug-in installation
Dimensions (H x W x D)3.36" x 8.83" x 14.62" (85.5 x 224.5 x 371.5mm)
Weight 17.6 lbs. (8kg)
Environmental
Temperature -40°F to 113°F (-40°C to 50°C) at full rated output
96 Amps at 55°C
Altitude Up to 6562' (2000m) at full rated output
Ventilation Front to back with speed-controlled fan (field replaceable)
Audible Noise The rectifier does not produce sound levels above 50dB(A), measured 0.6m in front of the
rectifier, at the same horizontal line as the middle of the rectifier at 25°C
Safety Compliance UL recognized (UL60950) for USA & Canada, CE marked
*Specify R48-5800L for 208V.
6
Visual indicator color
Green
Yellow
Red
Flashing red
Page 7
Emerson Network Power —
a complete spectrum of best-in-class reliable
power, precision environmental and connectivity
solutions for today’s telecommunications and
data network infrastructure
R48-5800 Rectifier – Electrical Specifications*
AC Input
Nominal Voltage Three phase 380/480VAC
Operating Voltage Range R48-5800: 304VAC to 530VAC (output reduced 50% from 260-304VAC)
R48-5800L: 145VAC to 230VAC (output reduced 50% from 145-176VAC)
Frequency 45 Hz to 65 Hz
Power Factor (PF) >0.98 from 50% to 100% load
Total Harmonic Distortion <5% from 50% to 100% load
Input Current Max 20 amp
Inrush Current Inrush current does not exceed 150% of the rated input steady state peak value.
Input Protection If the input voltage decreases or increases beyond a non-adjustable predetermined value, the recti-
fier circuitry shuts down, disabling the output. The rectifier will recover automatically when the
AC input is re-established and exceeds 260VAC (low voltage restart point) or when it decreases to
530VAC (high voltage restart point). Overcurrent is protected by an internal fuse.
Operating Efficiency 93% peak
92.6% at full load
DC Output
Output Voltage Range -42.0VDC to -58.0VDC
Output Power 5800W maximum from 304VAC to 530VAC
Output Current Nominal 110 amps, adjustable from 10-110 amps
Regulation Steady state output voltage remains within +/-0.25% for any combination of input voltage
from 5% to 100% load
Voice Band Noise The voice-frequency noise generated by a rectifier does not exceed 32dBrnC output noise
from 10% to 100% load
Wide Band Noise Does not exceed 250 mv peak-to-peak, or 100 mv rms per Telcordia GR-947-CORE
Psophometric Noise Does not exceed 1 mv from 10% to 100% load
Protection
Current Limiting The output current is limited to 110 amps
Over Current Internal fuse
High Voltage Shutdown If rectifier detects over voltage it will turn off. After 5 seconds it will restart; if it encounters an over
voltage within 5 minutes it will turn off and remain off until reset.
*Specify R48-5800L for 208V.
Output Power vs. Input Voltage
at Ambient Temp. <45°C
120
100
80
60
40
20
% of max output power
0
250300350400450500550
Input Voltage (VAC)
Output Power vs. Temperature
at Input Voltage >304VAC
120
100
80
60
40
20
0
% of max output power
-40-20 -1010-30020 30 40 50 60 70 80
Temperature (C°)
Output Voltage vs. Output Current,
max. Output Power 5800W
For ordering information, request SAG582140001. For additional specification, engineering and installation
information use specification number 582140001, model number 801 NLEB.
Output Current (A)
7
Page 8
Emerson (NYSE: EMR), based in St. Louis, is a global leader in bringing technology and engineering together to provide
innovative solutions to customers through its network power, process management, industrial automation, climate
technologies, and appliance and tools businesses. For more information, visit: Emerson.com.
Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™
from grid to chip for telecommunication networks, data centers, health care and industrial facilities. Emerson Network
Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems,
embedded computing and power, integrated racks and enclosures, power switching and controls, monitoring, and
connectivity. All solutions are supported globally by local Emerson Network Power service technicians. For more
information on Emerson Network Power’s full suite of solutions specifically supporting the communications network
infrastructure, including NetSpan™, NetReach™ and NetXtend™ outside plant enclosures and equipment, NetSure® DC
power systems, and turnkey services, visit: EmersonNetworkPower.com/EnergySystems.
Learn more about Emerson Network Power products and services at: EmersonNetworkPower.com.
This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be
used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson
Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service.
®
Emerson
subsidiaries.
Emerson Network Power
Energy Systems, North America
, Emerson Network Power™, Business-Critical Continuity™, NetSpan™, NetReach™, NetXtend™ and NetSure® are trademarks of Emerson Electric Co. and/or one of its
Emerson Network Power.
The global leader in enabling Business-Critical Continuity