Emerson NetSure 801 DC Brochures and Data Sheets

NetSure® 801 Series
DC Power System
DC Power for
Business-Critical Continuity
Key Features
n
Modular design — simple to install and operate; allows incremental cost-effective system growth
n
Single point adjustment — no tools required to change settings and make adjustments; MCA controls up to 168 rectifiers
n
LMS1000 monitoring with a single plug in card — includes
SNMP and Web interface
n
Remote access — options allow users to view, control and interact with the system using an Ethernet (Telnet, web pages, SNMP or TL1), modem or RS 232
n
Plug’n’play — add rectifiers without changing the settings and making adjustments; no system interruption
n
High density — compact design takes up less floor space; houses (24) 5800 watt rectifiers per bay, distribution bays are rated for 6000 amps in continuous operation.
n
Efficiency — industry leading 3-phase rectifier; 93% peak,
92.6% at full load
n
Cabled plant — offers unlimited configuration options
n
PowerShare — allows the reuse of existing equipment with NetSure
n
Safety compliance — NEBS Level 3 compliance (pending 3rd party testing); UL Listed to UL subject 1801
801
5,800 watt rectifiers from Emerson Network Power provide up to 110 amps each. With 24 units per bay, these rectifiers provide up to a 2,640 amp output in a 24.375" x 30" footprint.
Description
The modular NetSure™ 801 power system with 5800 watt rectifiers provides up to 16,800 amps of power for -48 volt systems. The basic components of the system include 2640 amp power bays which house the rectifiers and MCA chassis, and 6000 amp distribution bays. The cabled architecture allows the placement of the bays anywhere the user desires without regard to any specific order. This also makes it more user friendly in applications where existing obstacles, such as support columns, need to be accommodated. The total plant size is defined by the maximum capacity of the Main Battery Termination Bars (MBTB).
The NetSure a powerful, microprocessor-based meter, control and alarm system capable of monitoring and controlling up to 168 rectifiers. The MCA provides a 4 line,
801 power system contains
40-character alphanumeric display, which can be activated at the touch of a keypad. Each rectifier bay can accommodate up to 24 plug’n’play rectifiers, which are controlled by the MCA. Additional bays can be added as load requirements increase.
The NetSure 6000 amp modular distribution bays. Each bay can be configured with up to 70 positions of fuses and circuit breakers from 1-800 amps. Multiple bays may be used to support load levels in excess of 16,800 amps. Contact an Emerson application expert at 1-800-800-1280.
801 power system offers
Application
The NetSure™ 801 system is ideal for wireline, wireless and data center applica­tions such as switch sites, co-location, MTSO and data processing centers.
NetSure™ 801 System Elements
1 2
3
4
5
6
7
7
7
7
Main Power Bay
1
(Individual Feed, No Breakers)
Distribution Bay
2
AC Panel
3
(Dual Feed with Breakers)
MCA
4
Rectifiers
5
Bullet Fuse/Breaker Panel (Optional)
6
(4) 1500 Amp Fuse/Breaker
7
Distribution Buses