NetReach™ XC UN Swing-Out Series
Integrated Cross Connect Solution

Key Features
Description
n
Hinged, swing-out, split-block
field provides easy and complete
access to splice chambers
n
Simplified split-drawer base
provides ease of cabinet
installation over in-place
cables and facilitates cabinet
rehabilitation
n
RLS50 blocks meet CAT5 and
CAT5E channel specifications
when terminated with CAT5 or
CAT5E cable
n
Single cabinet mounting footprint
for all sizes reduces number of
pads required
n
Moisture and insect barrier base
eliminates need for pea gravel
n
Overhanging rain guards, closed
cell neoprene door gasketing,
and screened louvers keep out
moisture, minimize condensation,
and provide weather protection
n
High dielectric urethane potting
compound expands and contracts
with temperature variations for
added corrosion protection and
insect resistance on all blocks
n
Single access cabinets can be
expanded to double access
cabinets
n
Treated with a powder-coat
paint process on the interior and
exterior for extended life
The pad-mounted UN Swing-Out
Series (formerly Universal Series)
cross-connect interface system has
a center-feed horizontal jumper run
for efficient installation of jumpers.
Cabinets can be equipped with
RLS50 self-strip terminal blocks,
and are available in pair counts up
to 5400 pairs.
The three primary cabinet sizes
accommodate all feeder/distribution needs from 900 to 5400 pairs.
Single access cabinets accommodate up to 2700-pair, and double-access
Application
cabinets accommodate up to 5400-pairs.
Cabinets are mounted directly to the pad
through holes in turned-in flanges of the
base, and the RLS50 blocks provide rapid
pair-at-a-time no-strip jumpering.
Universal Series cabinets are intended
for use as a serving area interface or in a
standard cross-connect application for
feeder and distribution cables.
The cabinets are manufactured of heavy
gauge mill-galvanized steel, treated with a
finishing process for longer life. Housing
color is off-white.
Dimensions
— Overall Housing —
Pair Count H W D
Single Access
600-1200 47-in. 41-in. 24-in.
1300-1800 50-in. 54-in. 24-in.
1900-2700 75-in. 53-in. 22-in.
Double Access
1200-2400 47-in. 41-in. 24-in.
1800-3600 50-in. 54-in. 24-in.
2700-5400 75-in. 53-in. 22-in.
2

Emerson Network Power —
a complete spectrum of best-in-class reliable
power, precision environmental and connectivity
solutions for today’s telecommunications
and data network infrastructure
Ordering Matrix
Connection Type FS = Field splice
Cabinet Style UN = Universal Swing-Out Series
Block Type RLS = RLS50 IDC blocks
CQF = CQF50 binding terminal blocks (manufacturer discontinued)
Pair Count 1200 = 1200 pair
2700 = 2700 pair
5400 = 5400 pair
Access S = Single
D = Double
Field Splice Connector Modules* CF = 710, capless, receptacle, gel-filled
GBM/CBM = 4005-GBM, gel-filled
DPM = 3M 4005-DPM, dry, (MS2)
blank = No connectors (FS)
Color W = Off-White
* Field splice cabinets have 25-pr. harnesses exiting from the back of the blocks.
The 25-pr. connector modules are typically installed at the end of harnesses.
Mounting Templates
Catalog Number P71315
Part Number F571315
Description Metal mounting template
(mounting center dimensions):
13.00"W x 8.50"D for 100-600
pair standard cabinets
37.88"W x 8.50"D for 700-5400
pair standard cabinets
NOTE: Metal mounting template (F571315), to be embedded in poured
concrete pad, must be purchased separately.
P71315
3

EmersonNetworkPower.com
EmersonNetworkPower.com/EnergySystems (North America)
© Emerson Network Power, Energy Systems, North America, Inc. 2014.
Business-Critical Continuity™, Emerson Network Power™, the Emer son Net work Power l ogo, Emer son™ and Consi der it Solv ed are ser vice mark s and
tradem arks of Eme rson Elec tric Co. En ergyMas ter
Netw ork Power, Ener gy Systems , North Am erica, In c. Any other p roduct , brand, or co mpany names o r logos are t he proper ty of the r especti ve owner.
™
, eSure™, NetPerform™, NetReach™, NetSpan™, NetSu re™ and NetXtend™ are trad emarks of E merson
011100B-NRXCUN / 1214
While ev ery precau tion has been t aken to ensure acc uracy and
completeness herein, Emerson Electric Co. assumes no responsibility,
and disc laims all liabil ity, for damages r esulting fr om use of this
inform ation or for any er rors or omis sions. Specif ications su bject to
change without notice.