Liebert® PSS™ Surge Suppressor
Quick-Start Guide - Models PRF 1080, NET 1080T
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions that should be
followed during installation and maintenance of the Liebert
PSS surge suppressor.
• Intended for installation in a controlled environment.
• Maximum ambient temperature 104°F (40°C).
CAUTION
!
To reduce the risk of fire, connect only to a circuit
provided with 15 amperes maximum branch circuit
overcurrent protection in accordance with the
national code, ANSI/NFPA 70.
• Do not connect equipment that may overload the surge
suppressor or demand half-wave rectification, such as a
laser printer.
• Connect the surge suppressor only to an earthed /
grounded outlet that meets national and local electrical
safety guidelines.
SETUP
Congratulations on purchasing the Liebert PSS Surge
Suppressor.
The Liebert PSS is designed to protect 120 Volt electronic
equipment. The surge suppressor is capable of carrying up to
15A current.
Follow these instructions to ensure that your Liebert PSS
surge suppressor is properly installed and functioning.
• Locate the surge suppressor near a wall outlet. Do not
use an extension cord between the surge suppressor and
the outlet.
• The Liebert PSS has been designed for small office/home
office use only; it is NOT recommended for use in lifesupport applications.
• In the event of an emergency, press the OFF button and
disconnect the power cord from the AC power supply to
properly disable the surge suppressor.
• Do not attach power strips or other surge suppressors to
the Liebert PSS surge suppressor.
• Do not attempt to service any parts inside the surge suppressor. Failure to adhere to this could cause personal
injury or equipment malfunction and void the warranty.
• For technical support:
• Visit www.liebert.com or
• Send an e-mail to
upstech@emersonnetworkpower.com.
Step 1 Connect AC Equipment to the Liebert PSS
(Models PRF 1080 and NET 1080T)
• Plug the surge suppressor into a grounded outlet only.
• Plug the cords from your computer, home entertainment or
other electrical equipment into the surge suppressor’s
receptacles.
• For large transformer blocks, use one of the three
dedicated outlets on your surge suppressor.
Step 2 Connect Network Electronics
(Model NET 1080T only)
• Disconnect the end of your network line at the wall or
modem end.
• Connect it to one of the OUTPUT connections on the
NET 1080T.
• Connect a patch cord to the INPUT connection on the
NET 1080T.
• Connect the other end of the patch cord to the original
wall or modem outlet.
Step 3 Apply Power to the Liebert PSS
(Models PRF 1080 and NET 1080T)
• Turn the power switch to the ON position.
CAUTION
!
This protector is intended for indoor use on
communication loop circuits, which have been
isolated from the Public Switched Telephone
Network. The communication loop circuits shall not
be exposed to accidental contact with electrical light
and/or power conductors.
FEATURES
Indicators
Each Liebert PSS has a visual SURGE PROTECTION
indicator that illuminates (green) to show that the surge
Wall Mounting
If wall mounting is desired, two keyed slots are provided and
located on the back of the surge suppressor.
suppressor is functioning properly.
The Liebert PSS also has an audible alarm to alert you if
the suppression fails. Surge suppressors are often hidden
Wall Mounting Detail
Rear View
from view behind furniture and other objects that prevent you
from seeing the visual indicator.
TROUBLESHOOTING
If the Liebert PSS malfunctions during operation, check the following chart for proper adjustment. For further assistance,
please contact your local Emerson Network Power representative.
Problem Recommended Actions
The green
GROUND
indicator
does not
illuminate.
The green
SURGE
PROTECTION
indicator
does not
illuminate
when
powered ON.
Try plugging the Liebert PSS into a different wall receptacle.
• If the indicator illuminates, the Liebert PSS is operating properly and the first wall receptacle needs repair. Please
contact an electrician to repair the faulty receptacle.
• If the indicator does NOT illuminate in a different receptacle:
• Your building wiring might not contain a ground conductor. In this case, the indicator light will not illuminate but
you will still have power out of the Liebert PSS.
• The Liebert PSS may have been damaged. Please contact your supplier for any warranty return/repair
instructions.
Try plugging the Liebert PSS into a different wall receptacle.
• If the indicator illuminates, the Liebert PSS is operating properly and the first wall receptacle needs repair. Please
contact an electrician to repair the faulty receptacle.
• If the indicator does NOT illuminate in a different receptacle:
• The Liebert PSS may have been overloaded and the internal circuit breaker may have tripped. Remove all
loads from device and reset the circuit breaker by pushing the button back in. Replace loads one at a time.
• The Liebert PSS may have been damaged. Please contact your supplier for any warranty return/repair
instructions.
SPECIFICATIONS
Model Number PRF 1080 NET 1080T
AC Power Protection
Nominal Operating Voltage 120V
Maximum Operating Voltage 130V
Rated Output 15A
Mode of Protection L-N, L-G, N-G
Peak Surge Rating 72,000A
Surge Energy 1080 Joules
EMI/RFI Filtration Yes
UL 1449 Surge Voltage Rating 330V
Network Protection
Connection Type — RJ45
Protection — 2 Pair
© 2008 Liebert Corporation. All rights reserved throughout the
world. Specifications subject to change without notice.
® Liebert is a registered trademark of Liebert Corporation.
All names referred to are trademarks or registered
trademarks of their respective owners.
IO-22002_REV0_07-08
Technical Support / Service
800-222-5877
(Outside U.S. 614-841-6755)
upstech@emersonnetworkpower.com
Web site: www.liebert.com
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229