Emerson MPH2 Technical Documents

Emerson Network Power® MPH2™ Rack PDU
MPH2
2.96A
2kWh
i
TX
MPH2
Managed Rack
Power Distribution
RX
L1 L2
L3
1
User Manual
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY SYMBOLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.1 General Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Model Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Appearance and Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3.1 Controls and Indicators—RPC2™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3.2 Controls and Indicators—LED’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3.3 Controls and Indicators—Onboard LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3.4 Power Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.3.5 Hard-Wired Connection Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.1 Attaching Input Power Cords—Hard-Wired Models Only. . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1.1 Attaching Input Power Cords Without Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.1.2 Attaching Input Power Cords With Conduit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 Tool-less Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.3 Installing an MPH2 in an Emerson
2.3.1 Mounting Hardware and Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.3.2 Safety Earth Ground Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.3.3 Recommended Electrical Backup Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.4 Connecting Rack Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.5 Installing Optional Items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.5.1 RPC Basic Display Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.5.2 Temperature/Humidity Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
®
Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.0 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
3.1 Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.1.1 Getting Information Through the Onboard LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.1.2 Adjusting the Onboard LCD’s Contrast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.1.3 Adjusting the Onboard LCD’s Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.1.4 Obtain MPH2 System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.1.5 Determine IP or MAC Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.1.6 View Input Level Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.1.7 View Active Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.1.8 View Branch Level Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.1.9 View Outlet Level Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.1.10 View Sensor List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.1.11 View Sensor Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.1.12 Opening and Closing Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.1.13 Silence an Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.0 EMERSON® MPH2 RACK PDU SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
5.0 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
i
FIGURES
Figure 1 Vertical MPH2 rack PDU Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 2 MPH2 major monitoring and management features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 3 MPH2 LCD and LED’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 4 Branch and outlet identification—Units with no monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 5 Branch and outlet identification—Units with individually monitored and managed outlets . . . . 7
Figure 6 Circuit breaker branch identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 7 Hard-wired connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 8 Disassembling the MPH2 for installing an input power cable in conduit . . . . . . . . . . . . . . . . . . . 11
Figure 9 Disassembling the MPH2 for installing an input power cable in conduit . . . . . . . . . . . . . . . . . . . 11
Figure 10 Tool-less mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 11 Installing in an Emerson rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 12 Earth-ground connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 13 RPC BDM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 14 Inserting the spring nut into a T-slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 15 MPH2 onboard LCD and control keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 16 MPH2 onboard LCD layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 17 Adjust LCD contrast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 18 Flip LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 19 MPH2 rack PDU information screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 20 IP address in MPH2 Onboard LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 21 Input level screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 22 Alarm icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 23 Alarm list screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 24 Branch level information screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 25 Outlet level information screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 26 Sensor list screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 27 Sensor information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 28 Configuration in progress screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 29 Turning Off or resetting a circuit breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 30 Silence an alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
TABLES
Table 1 Hard-wired models—Connection terminal ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 2 Terminal tightening torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 3 Upstream circuit breaker rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
ii
IMPORTANT SAFETY INSTRUCTIONS
!
!
!
!

SAVE THESE INSTRUCTIONS

This safety sheet contains important safety instructions. Read all safety, installation and operating instructions before installing the Emerson Network Power MPH2 rack power distribution unit (PDU). Adhere to all warnings on the unit and in this safety sheet. Follow all operating and user instructions.
• The MPH2 rack PDU is designed for information technology equipment. The MPH2 rack PDU is not intended for use with life support or other designated critical devices. If uncertain about its intended application, consult your local dealer or Emerson representative.
• Maximum load must not exceed the rating shown on the MPH2 rack PDU nameplate.
• The rated line voltage must not exceed 240VAC for connection to AC power distribution systems with an isolated or high-impedance ground.
• Operate the MPH2 rack PDU in an indoor environment only in an ambient temperature range of 32°F to 140°F (0°C to 60°C) for 24A or less input models and 32°F to 122°F (0°C to 50°C) for 40A and 48A input models.
• Install the MPH2 rack PDU in a clean environment, free of conductive contaminants, moisture, flammable liquids, gases and corrosive substances.
• The MPH2 rack PDU must be installed in a restricted-access location. A restricted-access location is an area where access is possible only through the use of a tool or lock and key or other means of security, and is controlled by the authority responsible for the location.
• The MPH2 rack PDU has no user-serviceable parts. Under no circumstances attempt to gain internal access due to the risk of electric shock or burn.
• Refer any unexpected behavior or unusual fault conditions to your local dealer, Emerson representative or Emerson Network Power Applications Engineering.
• Emerson recommends powering only devices with safety agency approval from the MPH2 rack PDU.
• For permanently connected MPH2 rack PDU’s (hard-wired versions), a readily accessible disconnect device must be incorporated external to the equipment.
• For MPH2 rack PDU’s with integral plugs, the socket/ outlet must be installed near the equipment and must be easily accessible.

Important Safety Instructions

WARNING
Opening or removing end caps from an MPH2 rack PDU may expose personnel to lethal voltages within the rack PDU. Observe all cautions and warnings. Failure to do so may result in serious injury or death. MPH2 rack PDU units contain no user-serviceable parts. For service or technical support, contact Emerson Network Power Applications Engineering or your local Emerson representative. Do not attempt to service this product yourself.
CAUTION
Connecting an MPH2 rack PDU to a power supply with an incorrect rating in voltage or amperes may damage the connected equipment and your MPH2 rack PDU. For questions about the power supply connections, contact Emerson Network Power Applications Engineering or your local Emerson representative.
CAUTION
Ensure that the ratings of the electric circuit of each connected device meets the specified rating at each branch and outlet.
NOTE
For power management purposes, record the outlet where each piece of equipment is connected. Outlets on the MPH2 rack PDU have a numeric designation. The MPH2 rack PDU identifies the outlets with numbers and are grouped by branch with a letter referring to the proper circuit breaker.
1 Emerson® MPH2
Important Safety Instructions
!
CAUTION
All configuration steps must be completed before attempting to start equipment connected to the MPH2 rack PDU.

EUROPEAN UNION

Notice to European Union Customers: Disposal of Old Appliances
This product uses components that are dangerous for the environment, such as electronic cards and other electronic components. Any component that is removed must be taken to specialized collection and disposal centers. If this unit must be dismantled, this must be done by a specialized center for collection and disposal of electric and electronics appliances or other dangerous substances. This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC. The “crossed-out wheelie bin” symbol at right is placed on this product to encourage you to recycle wherever possible.
Please be environmentally responsible and recycle this product through your recycling facility at its end of life. Do not dispose of this product as unsorted municipal waste. Follow local municipal waste ordinances for proper disposal provisions to reduce the environmental impact of waste electrical and electronic equipment (WEEE).
For information regarding the scrapping of this equipment, go to http://www.eu.emersonnetworkpower.com
(“Products session” or “Contact us” session) or call Emerson’s worldwide technical support at:
• 00 80011554499 (toll free number)
• +39 0298250222 (toll number based in Italy)

ROHS Compliance

The MPH2 rack PDU modules comply with the Restriction of Hazardous Substances directive (ROHS), prohibiting use of six hazardous materials manufacturing of electronics, including lead-free solder.

FCC Compliance

This unit complies with the limits for a Class A device pursuant to Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
NOTE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Emerson® MPH2
Operation of this equipment in a residential area is likely to cause harmful interference that the user must correct, including the expense of all corrective modifications.
2
SAFETY SYMBOLS
The following symbols may appear within the documentation or on the product.
Symbol Meaning
High Temperature
Alerts the user where the enclosure temperature may exceed 158°F (70°C) while operating under high-ambient temperature and at maximally rated load.
Instructions
Signifies the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Dangerous Voltage
Warns about the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Power On
Indicates the principal On/Off switch is in the On position.

Safety Symbols

Power Off
Indicates the principal On/Off switch is in the Off position.
Protective Grounding Terminal
Indicates a terminal that must be connected to earth ground before any other connections to the equipment may be made.
3 Emerson® MPH2

1.0 INTRODUCTION

The Emerson Network Power® MPH2™ is the most intelligent, high-availability line of managed rack PDU’s. It offers remote monitoring and control capabilities as well as environmental sensors with multiple power input selections and output configurations.

Metering Levels

Four types of MPH2 are available that offer metering of all electrical information including input, branch and outlet levels, as well as integration with environmental sensors. The available information varies by type of MPH2.

Mounting

Rack PDU’s are available for mounting in vertical configuration in standard or network enclosures.
Power cords on MPH2 models that mount vertically in a zero-U configuration may be switched from one end to the other to accommodate top or bottom cable entry into the rack.

Locking Outlets - IEC Type Only

Locking outlets are available on models with IEC outlets. The locking feature requires optional power cords to be installed on devices powered by the MPH2.
The outlets require no modification to function properly with non-locking power cords.

Overcurrent Protection

Introduction
All MPH2 rack PDU units with input current rating of 30A and higher feature 100% rated hydraulic-magnetic breakers. For all UL-listed models, the maximum cord and plug-connected loading is limited to 80% continuous loading, as required by UL in accordance with the National Electric Code.
Low-profile circuit breakers are used on all MPH2 rack PDU’s with two or three branch circuits. Standard-profile circuit breakers are used on MPH2 rack PDU’s that have six branch circuits or have a 240VAC rating. Each type of circuit breaker is a flush-mount, rocker style (see Figure 29).

Integrated Monitoring and Management

The factory-installed Emerson RPC2™ communications module permits managing the MPH2 rack PDU over a secure Web page and SNMP-based network management system. The RPC2 permits interconnecting up to four rack PDU’s for monitoring and management.
NOTE
Refer to the RPC2 communications module user manual, SL-20841, for detailed instructions on installing and using the RPC2 module. The document is available at Emerson’s Web site:
http://www.emersonnetworkpower.com
A rack PDU can be monitored locally through its onboard LCD, through a Web interface or through an optional display module, either the RPC BDM (Part# RPCBDM-1000). The display module connects directly to the RPC2 communications module. It can be handheld, mounted in or on the rack or mounted on a wall near the rack PDU it is monitoring.
Multiple MPH2 rack PDU’s can be managed with these software applications:
•Avocent
•Avocent DSView
• Emerson’s Trellis
•Liebert
• Liebert SiteScan
®
Rack Power Manager software
management software
Real-Time Infrastructure Optimization platform software
®
Nform®, which adds group-based outlet management
®
Emerson® MPH2
4

Figure 1 Vertical MPH2 rack PDU Configuration

Network
Connection
(10MB/100M
B/1GB)
Monitoring Station
RPC™ Basic
Display Module
Serial Appliance
Vertical
MPH2
rack PDU
Connected Equipment
Rack PDU Array
Sensors
Integrated and
Modular
Introduction

1.1 General Characteristics

• Input ampacities include 16A or 32A for European Union versions and 16A to 48A for North American versions.
• Single-phase and three-phase.
• Input voltages include 100-120VAC, 120/208VAC, 200-240/415VAC.
• Outlets types include NEMA 5-20, IEC 320 C13 and IEC 320 C19
• Input connection supports a highly flexible fixed power cord or hard-wired connection to user accessible terminal block.

1.2 Model Types

There are four types of MPH2 rack PDU.
Type R—Outlet Metered, Outlet Switched: Supports metering of the overall input, individual branches and individual outlets; also supports individual On/Off control of each outlet.
Type M—Outlet Metered: Supports metering of the overall input, individual branches and individual outlets.
Type C—Rack PDU Metered, Outlet Switched: Supports metering of the overall input and of individual branches and supports individual On/Off control of each outlet.
Type B—Rack PDU Metered: Provides basic power distribution and supports metering of the overall input and of the individual branches.
5 Emerson® MPH2

1.3 Appearance and Components

Serial Port
USB Port
Display Port
Link Port
Network Port
Sensor Port
Reset Button Access
1.3.1 Controls and Indicators—RPC2
The MPH2 rack PDU is monitored and managed by the factory-installed RPC2 communications module. This manual presents information about the MPH2’s functions and features. For details on operating the MPH2 through the RPC2 communications module, refer to the RPC2 user manual, SL-20841. The document is available at Emerson’s Web site:
http://www.emersonnetworkpower.com
The RPC2 is installed near the middle of the MPH2 rack PDU. The central location eases connections whichever orientation is required for power cabling.
The RPC2’s Web-based interface provides system operating measurements, as well as readings from optional SN temperature or temperature/humidity sensors. The RPC2 provides basic information about the MPH2 rack PDU, such as firmware version, unit rating, model number and serial number.
Figure 2 MPH2 major monitoring and management features
Introduction

1.3.2 Controls and Indicators—LED’s

The MPH2 rack PDU also has LED’s that indicate outlet and branch status and system information. The LED’s flash, pulse or change colors to indicate an event or alarm condition (for details on how LED’s respond to events and alarms, refer to 5.0 - Troubleshooting.
NOTE
Units with a “B” as the fourth character in the model name (MPHBxxxx) do not have LED’s at their outlets. The branch and outlet LED behavior in 5.0 - Troubleshooting and elsewhere in this document does not apply to these units.
Outlets on units with an “M” as the fourth character in the model name (MPHMxxxx) cannot be turned Off. LED’s at outlets on these models are always either on continuously or flashing when input power is present.

1.3.3 Controls and Indicators—Onboard LCD

Emerson’s MPH2 has an integrated, onboard LCD that can be used to view information about the rack PDU. The information available depends on the type of MPH2. For additional information about the onboard LCD, refer to 3.1.1 - Getting Information Through the Onboard LCD.
Emerson® MPH2
6
Figure 3 MPH2 LCD and LED’s
MPH2
121. 1V 359W
2.96A
2kWh
i
TX
MPH2
Managed Rack
Power Distribution
RX
L1 L2
L3
1
Onboard LCD
Left Arrow Key Right Arrow KeySelect Key
Line Input Status LED’s
Typ e B M odels
Branch B Outlets
Not shown
Branch Identification
Outlet Identification
Type C, R and M Models
LED’s at Each Outlet
(Denote Outlet Status)
Outlet
Identification
Outlet
Identification
Branch
Identification
Branch
Identification

1.3.4 Power Components

Introduction
The component location and type depend on the model of the MPH2 rack PDU. For example, units with a “B” as the fourth character in the model name do not have LED’s at their outlets; see Figures 4, 5, 6 and 7.
Figure 4 Branch and outlet identification—Units with no monitoring
Figure 5 Branch and outlet identification—Units with individually monitored and managed outlets
7 Emerson® MPH2
Loading...
+ 25 hidden pages