Emerson Micro Motion F Series, Micro Motion F300A, Micro Motion F025, Micro Motion F100, Micro Motion F200 Installation Manual

...
Micro Motion
®
F-Series Sensor
Installation Manual
Installation Manual
P/N 20002298, Rev. A April 2005
2 Sensor Installation: F-Series
Before You Begin
Before You Begin
This manual describes how to install a Micro Motion® F-Series sensor. The following information is provided in this manual:
Customer service
For technical assistance, phone the Micro Motion Customer Service Department:
• In the U.S.A., phone 1-800-522-MASS (1-800-522-6277)
• In Canada and Latin America, phone (303) 527-5200
• In Asia, phone (65) 6770-8155
• In the U.K., phone 0800 - 966 180 (toll free)
• Outside the U.K., phone +31 (0) 318 495 670
Customers outside the United States can also contact Micro Motion Customer Service by email:
• International.Support@EmersonProcess.com
Troubleshooting
Refer to the transmitter manual for troubleshooting help.
Specifications
Full product specifications can be found in the F-Series Product Data Sheet, which is available from the Micro Motion web site at www.micromotion.com.
Definitions
The term MVD
transmitter refers to the following transmitter models:
• Models 1500, 1700, 2500, and 2700
• Models 3500 and 3700
Installation steps
Determining a Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
Orienting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
Mounting the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 17
Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
Additional information
Purge Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 22
Return Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
©2005, Micro Motion, Inc. All rights reserved. Micro Motion is a registered trademark of Micro Motion, Inc. The Micro Motion and Emerson logos are trademarks of Emerson Electric Co. All other trademarks are property of their respective owners.
Sensor Installation: F-Series 3
Before You Begin
European installations
This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product.
The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at www.micromotion.com/atex or through your local Micro Motion support center.
Purge plugs
If you remove a purge plug from the sensor case, it will be necessary to repurge the case. Refer to Case purging procedure on page 22 for more information about repurging the sensor case.
Installation options
The F-Series sensor makes up one part of a Coriolis flowmeter. The other part is a transmitter. F-Series sensors (except Model F300A) are available with the following electronics interfaces:
• An integral core processor for connecting to a 4-wire remotely mounted transmitter or to a user-supplied remote host (Figure 1).
• An integrally mounted Model 1700 or 2700 transmitter (Figure 2).
• A 9-wire junction box for connecting to a remotely mounted transmitter or a remotely mounted core processor (Figure 3).
• An integrally mounted IFT9701 transmitter (not available with Model F300) (Figure 4).
Model F300A sensors include a flexible conduit. Sensor electronics are mounted at the end of the flexible conduit. Model F300A sensors are available with:
• A core processor for connecting to a 4-wire remotely mounted transmitter or to a user-supplied remote host (Figure 5).
• A Model 1700 or 2700 transmitter (Figure 6).
• A 9-wire junction box for connecting to a remotely mounted transmitter or a remotely mounted core processor (Figure 7).
WARNING
Removing a purge plug compromises the secondary containment of the sensor and could expose the user to process fluid.
The user should take all necessary precautions when removing the purge plugs, because the sensor case may contain process fluid.
4 Sensor Installation: F-Series
Before You Begin
Figure 1 F-Series sensor with core processor
Approval tag
Flow direction arrow
Core processor housing
Calibration tag
Process connection
Approval tag
Calibration tag
Core processor housing
Purge fitting
Purge fitting
Sensor with purge fittings
Sensor Installation: F-Series 5
Before You Begin
Figure 2 F-Series sensor with integrally mounted Model 1700/2700 transmitter
Model 1700 or 2700 transmitter
Approval tag
Flow direction arrow
Core processor housing
Calibration tag
Process connection
Calibration tag
Approval tag
Purge fitting
Purge fitting
Model 1700 or 2700 transmitter
Sensor with purge fittings
6 Sensor Installation: F-Series
Before You Begin
Figure 3 F-Series sensor with junction box
Junction box
Approval tag
Flow direction arrow
Approval tag
Process connection
Calibration tag
Purge fitting
Purge fitting
Junction box
Sensor with purge fittings
Calibration tag
Sensor Installation: F-Series 7
Before You Begin
Figure 4 F-Series sensor with integrally mounted IFT9701 transmitter
Calibration tag
Flow direction arrow
Model IFT9701 transmitter
Approval tag
Process connection
Model IFT9701 transmitter
Approval tag
Calibration tag
Purge fitting
Purge fitting
Sensor with purge fittings
8 Sensor Installation: F-Series
Before You Begin
Figure 5 Model F300A sensor with flexible conduit extended core processor
Flow direction arrow
Core processor housing
Calibration tag
Process connection
Flexible conduit Length: 36 (914 mm) Minimum bend radius 2 1/8 (54 mm)
Approval tag
Purge fitting
(optional)
Purge fitting
(optional)