Emerson Liebert SmartSwitch User Manual

AC
Power
For Business-Critical Continuity
Liebert SmartSwitch
A Switching Solution For Reliable, Redundant AC Power
Now You Can Have Dual Cord Dependability
Critical
Load
UPS or
Utility A
UPS or
Utility B
PDU BPDU A
Liebert
SmartSwitch
If your electronics application is one of the many that
requires continuous operation — without tolerance for even
scheduled downtime — you need the reliability provided by
dual power sources.
Many of today’s servers and other computing systems
e equipped with dual power cords…designed to
ar provide built-in redundancy by allowing connection to two separate power sources. In a similar move, facilities are now introducing this level of dual cord reliability to critical equipment that operates on a single power input by supplying two independent electrical feeds. The key to making it all work, however, is to have a dependable switching mechanism to support it.
What Makes A Reliable Switch?
The transfer switch should have proven technology and design features to ensure that it will operate dependably when you need it. The swihching mechanism should be easy to configure, install, use and maintain.
A switch needs to operate swiftly and reliably enough to compensate for “fast” power failures such as UPS system failure, circuit breaker trip or operator error — without
ffecting operation of the protected equipment.
a
The Liebert SmartSwitch does exactly this by providing
pid switching between two independent AC power
a
r
s, for uninterrupted operation of critical
e
urc
o
s electronic equipment.
Liebert SmartSwitch Enhances The Availability Of Power To Your Critical Electronic Equipment
Modeled on proven UPS technology, the Liebert SmartSwitch point-of-use power transfer switch is placed at the most effective spot — the last connection upstream of the protected equipment — allowing dual AC power paths all the way up to the critical load. From design to operation and maintenance, Liebert SmartSwitch has the features that optimize power availability:
Features & Benefits
Flexibility:
n
Transfers manually or automatically.
n
Allows selection of preferred input source without rewiring or load shutdown.
n
Provides integral maintenance bypass to both input sources for servicing convenience.
er Availability:
gh
i
H
n
Switches quickly between two AC power sources,
er transfer time invisible to your
w
g po
akin
m protected equipment.
n
ws module replacement without load
Allo
own, with hot-swap electronics.
d
t
u
sh
n
Employs Break-Before-Make switching to
ate connecting together of the
limin
e
t power sources, even under faulted
n
de
n
pe
de
in conditions.
2
Liebert SmartSwitch provides automatic or manual transfer between dual utility or UPS sources, allowing dual AC power paths all the way up to the critical load.
Lowest Total Cost Of Ownership
n
etects potential switch failures before the
D problem becomes critical, through diagnostics and transfer tests.
Logic and Power Supplies
Source 1 Source 2Output
3.76"
COVER PLATE
S
TATUS CONTACTS CONNECTOR
R
S-232 CONNECTOR
11.1"
10.7"
2.5"
AI
R EXHAUST AREA
DO NOT BLOCK
8.0"8.0"2.0"
.75"
20.0"
51
51
52
52
ALTERNATE SOURCEPREFERRED SOURCE
INPUT, OUTPUT AND CONTROL CONNECTIONS LOCATED BEHIND REMOVABLE ACCESS DOORS
INPUT SOURCE 52 SOURCE 51
M C B A M C B A M C B A
DO DO DO
Bypass Switch Transfer Control
NORMAL
MAN. XFER 51
MAN. XFER 52
BYPASS TO 51
BYPASS TO 52
BYPASS / TRANSFER SWITCH (LOCATED BEHIND KEYLOCK COVER)
25.4"
25.4"
26.9"
LED SWITCH STATUS INDICATORS AND LABELS
REM
OVABLE "HOT-SWAPPABLE"
ELE
CTRONICS MODULE
KEYLOCK LATCH
0.28" (7MM) (6 MTG. HOLES)
2.25"
2.25"
3.15"
1/2" KNOCKOUT
0.88" (22mm) (3 PLACES)
AIR INTAKE 2 SIDES
TOP VIEW
FRONT VIEW
RIGHT SIDE VIEW
BOTTOM VIEW
18.3" (465mm)
19" (483mm)
17.25"
(438mm)
20.4"
(518mm)
NORMAL
MAN
. XFER 51
MAN
. XFER 52
BYPASS TO 51
BYPASS TO 52
BYPASS / TRANSFER SWITCH
(LOCATED BEHIND KEYLOCK COVER)
KEYLOCK LATCH
1/2" KNOCKOUT
0.88" (22mm) (TYP. 8 PLACES)
REMOVABLE
"HOT-SWAPPABLE"
ELECTRONICS
MODULE
18.5"
(469mm)
3.5" (88.9mm)5.20"
(132mm)
0.85"
(21.5mm)
INPUT & OUTPUT CONNECTIONS
OUTPUT RECEPTACLE
STATU S CO NTAC TS CONNECTOR
RS-232 CONNECTOR
0.279" (7mm) x
0.406" (10mm) SLOT (4 SLOTS)
LED SWITCH STATUS I
NDICATORS
11"
(279mm)
"HOT-SWAPPABLE" ELECTRONICS
20"
(508mm)
20"
(508mm)
51
52
51
52
PERFERRED SOURCE
ALTERNATE SOURCE
INPUT CONNECTIONS
OUTPUT RECEPTACLE
RELAY
CONTACTS
& RS-232
PORT
Convenient, from selection to maintenance.
n
Choice of output receptacles and connector is available to match your load specifications, simplifying system installation and setup.
n
Selectable preferred input feature allows you to determine the normal and alternate power source of your choice without rewiring or load shutdown.
n
Integral maintenance bypass to both input sources
rovides a safe and fast solution to servicing the
p Liebert SmartSwitch without disturbing your protected equipment.
n
Hot swappable electronics module and bypass feature allow your protected equipment to remain up and running, even when the Liebert SmartSwitch module is being replaced or serviced.
n
LED indicators provide at-a-glance operating status. Eight output contacts are available for remote status indication. RS232 ASCII communications port allows setpoint control and remote monitoring.
n
ETL Listed to UL Standard 1008 for safety.
n
CE Mark (50 Hz) — complies with EMC and low voltage directives.
Three different configurations allow the unit to be
laced under a raised floor, mounted on a wall or used
p in a rack, based on your site needs.
RACK MOUNT
WALL MOUNT
Liebert SmartSwitch includes manual transfer test capability to assure continued proper
ation.
r
pe
o
tS
ar
Hot swappable electronics module and bypass feature
w your protected
allo equipment to remain up and running, even
n the Sm
he
w is being serviced.
witch
on and setup.
ti
a
all
t
vailable
The unit is a with your choice of receptacles and connector,simplifying ins
LED in
dicators provide at-a-glance
g status. Eight output contacts
tin
a
r
pe
o are available for remote status indication. RS232 ASCII communications port allows setpoint control and remote monitoring.
OOR
ER FL
UND
With separate sections for
nnections and
o
r c
e
w
po electronics, Liebert SmartSwitch can sustain
wer to the load even when
po the electronics module is
g swapped for service.
in
be
Connections and Bypass Section
Hot-Swap Electronics Section
3
Liebert SmartSwitch
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power
Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection
Liebert Corporation
1050
Dearborn Drive
P.O.
Box 29186
Col
umbus, Ohio 43229
800 877 9222
Phone (U.S. &
Canada Onl
y)
614 888 0246
Phone (Outside U.S.)
614 841 6022
FAX
Via
Leonardo Da Vinci 8
Zona
Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 G
loucester Rd, Wanchai
Hong
Kong 852 25722201 Phone 852 28029250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.)
Technical Specifications
req No. of Conductors Breaker Size* Amps Enc.
odel Recept. Voltage Hz, Ph. Neu. Gnd Poles Amps Cont. Type
M
SIBMAR01 3743 208 60 2 — 1 2 20 16 R
S
SIBMBU01 3744 208 60 3 — 1 3 15 12 U
S
SIBMCU01 3753 208 60 2 1 2 30 24 U
S SSIBMDU01 3754 208 60 3 — 1 3 30 24 U SSIBMEU01 7324 208 60 3 1 3 60 48 U
S420R9VU01 420R9V 208 60 3 — 1 3 20 16 U
S
S430R9VU01 430R9V 208 60 3 — 1 3 30 24 U
S
F
SS460R9VU01 460R9V 208 60 3 — 1 3 60 48 U SS360R6WU01 360R6W 208 60 2 1 2 60 48 U
S515R2R01 5262 120 60 1 1 1 1 15 12 R
S
S515R4R01 (2) 5262 120 60 1 1 1 1 15 12 R
S
S520R2R01 5392CN 120 60 1 1 1 1 20 16 R
S
S520R4R01 (2) 5392CN 120 60 1 1 1 1 20 16 R
S
S530R1U01 9308 120 60 1 1 1 1 30 24 U
S
S615R2R01 5662 208 60 2 — 1 2 15 12 R
S SS620R2R01 6392CN 208 60 2 — 1 2 20 16 R SS630R1U01 9330 208 60 2 1 2 30 24 U SS1420R1U01 8410 120/208 60 2 1 1 2 20 16 U SS1430R1U01 9430 120/208 60 2 1 1 2 30 24 U SS1520R1U01 8420 208 60 3 1 3 20 16 U SSL515R1R01 4710 120 60 1 1 1 1 15 12 R SSL515R2R01 4700 120 60 1 1 1 1 15 12 R SSL520R1R01 2310 120 60 1 1 1 1 20 16 R SSL520R2R01 (2) 2310 120 60 1 1 1 1 20 16 R SSL530R1U01 2610 120 60 1 1 1 1 30 24 U SSL615R1R01 4560 208 60 2 1 2 15 12 R SSL615R2R01 4550 208 60 2 1 2 15 12 R SSL620R1R01 2320 208 60 2 1 2 20 16 R SSL620R2R01 (2) 2320 208 60 2 1 2 20 16 R SSL630R1U01 2620 208 60 2 1 2 30 24 U SSL1420R1U01 2410 120/208 60 2 1 1 2 20 16 U SSL1430R1U01 2710 120/208 60 2 1 1 2 30 24 U SSL1520R1U01 2420 208 60 3 1 3 20 16 U SSL1530R1U01 2720 208 60 3 1 3 30 24 U SSL2120R1U01 2510 120/208 60 3 1 1 3 20 16 U SSL2130R1U01 2810 120/208 60 3 1 1 3 30 24 U SSFW120R01 none 120 60 1 1 1 1 20 16 R SSFW130U01 none 120 60 1 1 1 1 30 24 U
W220R01
SF
S
W220NU01
SF
S SSFW230U01 none 208 60 2 1 2 30 24 U SSFW230NU01 none 120/208 60 2 1 1 2 30 24 U
W320U01
SF
S
one 208 60 2 1 2 20 16 R
n n
120/208 60 2 1 1 2 20 16 U
e
n
o
none 208 60 3 1 3 20 16 U SSFW320NU01 none 120/208 60 3 1 1 3 20 16 U SSFW330U01 none 208 60 3 1 3 30 24 U SSFW330NU01 none 120/208 60 3 1 1 3 30 24 U SSFW360U01 none 208 60 3 1 3 60 48 U
W360NU01
SF
S
W360NW01
SF
S SSFW360NX01 none 120/208 60 3 1 1 3 60 48 W SSFW116R01x none 230 50 1 1 1 1 16 16 R
W150U01x none 230 50 1 1 1 1 50 50 U
SF
S SSFW325U01x none 400 50 3 1 3 25 25 U SSFW325NU01x none 400/230 50 3 1 1 3 25 25 U
one 120/208 60 3 1 1 3 60 48 U
n
e 120/208 60 3 1 1 3 60 48 W
n
o
n
SSFW350U01x none 400 50 3 1 3 50 50 U SSFW350W01x none 400 50 3 1 3 50 50 W
W350X01x
SF
S
* Supply branch breaker not included in Liebert SmartSwitch. Consult factory for other recepticles.
none 400 50 3 1 3 50 50 W
ution has been taken to ensure accuracy and
eca
r
y p
r
e
v
le e
Whi completeness in this literature, Liebert Corporation assumes no
lity, and disclaims all liability for damages resulting
i
ponsib
s
e
r
e o
s
om u
fr
© 2007 Liebert Corporation. All rights reserved throughout
orld. Specifications subject to change without notice.
the w
s referred to are trademarks or registered trademarks
ame
All n of their respective owners.
ebert and the Liebert logo are registered trademarks
® Li of the Liebert Corporation.
SL-20300 (R10/07) Printed in USA
ation or for any errors or omissions.
m
or
f
f this in
usiness-Critical Continuity
B
r an
e
w
o
P are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.
rson Network Power logo
d the Eme
, Eme
rson Network
Loading...