Liebert GXT4 is a true on-line UPS that delivers
continuous, high-quality AC power to connected
equipment with no interruption when transferring
to battery. It provides protection from blackouts,
brownouts, sags, surges or noise interference.
For robust UPS protection up to 3kVA, the Liebert GXT4 UPS
provides industry leading features in a compact design:
On-line design means zero transfer time. When utility power
fails, your critical load remains supported by a seamless flow
of power.
Highest level of protection available in this capacity range.
Selectable Eco-Mode allows improved energy efficiency.
Easy serviceability with replaceable, hot-swappable batteries.
Controllable power to multiple devices via two independently
programmable pairs of outlets.
ENERGY STAR® qualifiedmodels available.
Intelligent-ready networking.
Ideally suited for:
Mission critical applications and systems
Network workstations
Servers
Network closets
Large network peripherals
VoIP
PCs
The Liebert GXT4 UPS package includes
everything you need for a fast and
easy installation:
UPS
Tower stands
Rackmount rails
Hardware
CD with software and manuals
Convenient lifting straps
Cables and ties
Page 2
The Proven Reliability Of True On-Line
Operation With The Features You Need Most
®
The Liebert
provides the capabilities often found only in larger systems. Get up
to 3kVA of capacity and battery backup. External battery cabinets
may be added for extended run time.
Liebert GXT4 UPS is a true on-line power source, which means power is
always being conditioned and supplied to the connected device(s), whatever
the quality of power coming in, a pure sinewave output results to ensure
equipment is protected.
Liebert GXT4 UPS includes:
GXT4™ UPS requires just a slim 2U of rack space, but
Liebert GXT4 UPS
Flexible, Reliable and
Low Total Cost Features
Flexibility:
Two Controllable Outlet Groups
Can be programmed for load shedding
and sequential restart if the UPS is
in overload or when selected backup
time remains.
Rotatable Display Panel
The color LCD display panel rotates 90° to
make the readout easy to see in rack or
tower installations.
Automatic Frequency Sensing
The UPS automatically adjusts to the input
frequency, 50Hz or 60Hz, and can also
be programmed to convert from one to
the other.
Mounting Flexibility
Rack rails and tower supports included.
Intelligent Communications
DCIM and BMS ready.
Power factor correction
Internal batteries
Frequency conversion
Internal automatic bypass to protect against adverse conditions
Manual bypass capability
Support for up to six external battery cabinets
Full Protection from Damaging Power Problems.
OutagesSagsSurgesSpikesNoise
TransientFrequency
Deviation
Under-
Voltage
Over-
Voltage
Harmonics
On-Line, Double Conversion UPS Protection
for Critical Applications
Dynamic
Bypass
Surge
Suppression
Power Factor
Correction/Rectifier
Charger
Inverter
Battery
FPO
ENERGY STAR® qualified
UPS models
Power Assurance Package
Provides Comprehensive
On-site services
Five-year protection plan
with 100% parts coverage and 7x24
emergency service.
On-Site installation and start-
up to provide pain-free multi-site
rollout management and free you from
hazardous material disposal in your
existing UPS, when applicable.
LoadUtility
On-site service support to free up
time-strapped IT resources.
Preventative Maintenance to
reduce the worry of downtime and
ensure rapid recovery.
2
Page 3
Liebert® GXT4™ UPS contains internal batteries, and is also able to support up to six
external battery cabinets – also 2U size.
High Availability:
Advance Early Warning of UPS System Status
Multiple audible and visual alarms immediately
alert you to critical issues.
3-17 minutes of Battery Backup Time at Full load
Provides ample time for an orderly shutdown. Optional matching external
battery cabinets offer additional backup time.
Overload Capability
Designed to handle output overload conditions.
Periodic Battery Testing
Provides automatic and manual self-diagnostic battery testing for peace of
mind to indicate if the battery is healthy.
Replaceable Hot Swappable Batteries
Easy to replace batteries to protect your investment by extending the
product life.
Power-Factor Correction
Prevents noise, harmonics and distortion from being passed on to
connected loads or from being fed back to the utility.
Internal Automatic and Manual Bypass Capability
Assures continuity of power to critical loads at all times. Convenient for
times of battery maintenance.
Intelligent Battery Management
Includes efficient three-stage charging technique and comprehensive
discharging protection that extends battery life.
Input Circuit Breaker
Provides increased protection to ease recovery from overloads.
Lightning and Surge Protection
The transient voltage surge suppression (TVSS) circuitry inside Liebert
GXT4 UPS provides additional protection for the connected equipment.
Low Total Cost Of Ownership:
High Output Power Factor
Liebert GXT4 UPS rated output power factor up to 0.9 better matches
switch-mode power supplies used in today’s IT equipment, providing
more efficient utilization of the UPS.
Multiple Choices For
Communication, Shutdown And Reporting:
SNMP And Web-Based Communication Options
Liebert IntelliSlot
SNMP (including SNMPv3) and IPv.6 and
web-based management to your Liebert
GXT4 UPS. Provides ability to monitor
and control your UPS from your network
management system or any PC running
Microsoft Internet Explorer.
Sends both SNMP traps and emails for
event notification, and automatically emails a
daily UPS history
Auto-senses 10M/100M Ethernet
The Liebert GXT4 UPS is also fully compatible with:
Liebert MultiLink™ shutdown software –included with the
Liebert GXT4 UPS
Liebert Nform™ monitoring software
Liebert Multiport multiplexing unit
Liebert Intellislot Relay Interface Card
Liebert SiteScanTrellis™ Platform USB Communications
Optional Liebert MicroPOD™ Output Distribution And
Maintenance Bypass Module
When your computer system can’t be without power, even
for scheduled UPS maintenance, the Liebert MicroPOD
Maintenance Bypass and Output Distribution Unit ensures
continuous uptime. It allows you to manually transfer
connected equipment to utility power via a maintenance
bypass switch, permitting scheduled service or UPS
replacement without the need to shut down connected
equipment. Features include:
2U height minimizes rack space requirements
Installs with plug-and-play ease
Two-year, no-hassle replacement warranty
®
Web Card provides
®
Selectable ECO-Mode
Connected equipment can be powered through the bypass while the
inverter remains idle, reducing electricity consumption.
Wide Input Voltage Window
Prolongs battery life by allowing the UPS to maximize the use of utility
power before transferring to battery when input voltage exceeds
specified limits.
Intelligent Fan Operation
Automatically changes rotation speed depending on system requirements
to decrease power consumption and noise.
Warranty Protection
The industry’s best warranty – No-hassle two-year warranty with advanced
UPS replacement in the event of problems. Shipping is free for both original
UPS return and the replacement unit. Optional one-year and three-year
extensions also available.
Liebert MicroPOD
3
Page 4
Specifications
Parameters
GXT4-500RT120
(500VA/450W)
Dimensions, D × W × H, in. (mm)16.2 x 16.9 x 3.4 (408 x 430 x 85)
Weight, lb (kg)40 (18.2)
Input AC
Voltage Range (typical)120VAC nominal; variable based on output load
Frequency40Hz ~ 70Hz; Auto Sensing
Input Power Cord10 ft. attached w/ NEMA 5-15P plug
Output AC
NEMA Output Receptacles5-15R × 6
Voltage110/115/120VAC (user-configurable); ±3%
Wavefo rmSine wave
Battery
Typ eValve-regulated, nonspillable, lead acid
Qty × V× Rating4 × 12V × 5.0Ah
Battery Part #GXT4-5A48BATKIT
Agency
SafetyUL 1778, cUL Listed
RFI/EMIFCC Class A
Surge ImmunityIEC 62040-2 2nd Ed
TransportationISTA Procedure 1A
®
ENERGY STAR
Dimensions, D × W × H, in.
(mm)
Weight, lb (kg)54.6 (24.8)56.1 (25.5)71.4 (32.4)
qualifedNoYesYes
Parameters
GXT4-1500RT120
(1500VA/1350W)
19.7 x 16.9 x 3.4 (497 × 430 × 85)23.7 x 16.9 x 3.4 (602 × 430 × 85)
GXT4-2000RT120
(2000VA/1800W)
Input AC
Voltage Range (typical)120VAC nominal; variable based on output load115-280VAC
Frequency40 - 70Hz; Auto Sensing
Input Power Cord
10 ft. attached w/
NEMA 5-15P plug
10 ft. attached w/
NEMA 5-20P plug
Output AC
NEMA Output Receptacles5-15R × 65-15/20R x 6
Voltage110/115/120VAC (user-configurable); ±3%
Wavefo rmSine wave
Battery
Typ eValve-regulated, nonspillable, lead acid
Qty × V× Rating4 × 12V × 9.0Ah6 × 12V × 9.0Ah
Battery Part #GXT4-9A48BATKITGXT4-9A72BATKIT
Agency
SafetyUL 1778, c-UL Listed
RFI/EMIFCC Class A
Surge ImmunityIEC 62040-2 2nd Ed
TransportationISTA Procedure 1A
®
ENERGY STAR
qualifedYesYesYesYes
GXT4-700RT120
(700VA/630W)
GXT4-3000RT120
(3000VA/2700W)
10 ft. attached w/
NEMA L5-30P plug
L5-30R×1
+5-20R×6
GXT4-1000RT120
(1000VA/900W)
GXT4-3000RT208
(3000VA/2700W)
10 ft. attached w/
NEMA L6-20P plug
L6-20R×1
+L6-15R×2
208/220/230/240
VAC
(user-configurable);
±3%
Emerson Network Power
Global Headquarters
1050 Dearborn Drive
P.O. Box 29186
800 877 9222 Phone (U.S. & Canada Only)
614 888 0246 Phone (Outside U.S.)
Contact@EmersonNetworkPower.com
Columbus, Ohio 43229
Emerson Network Power
Caribbean and Latin America
Office – United States of America
+1-954-984-3452 Phone
Ask.Cala@Emerson.com
Emerson Network Power Canada
3580 Laird Rd Unit 1
Mississauga
Ontario L5L 5Z7
Ask@EmersonNetworkPower.com
+1 905 569 8282
liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (outside U.S.)
EmersonNetworkPower.com
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.