Liebert® GXT3™, 5kVA-10kVA UPS Systems:
Big Protection, Small Package
Today’s converged networks require increased availability and reliability.
This has created a need for higher density power protection systems that
adapt to mixed load voltages and plug types, while remaining easy to
install and maintain.
New IT technologies, such as VoIP and PoE, have greatly increased power
demands. Unfortunately, as these requirements have risen, the amount of
space available for your protected equipment and related power support
systems has not.
Liebert IntelliSlot™ Webcard provides SNMP and
web-based management
The Liebert Solution
Liebert GXT3 UPS meets the need
for higher power capacities in small
spaces. This true on-line double
conversion UPS system is available in
5kVA – 10kVA models, and features
integrated maintenance bypass, as
well as optional extended battery
runtime. Add support — Emerson
Network Power Service — and it all
equals greater power assurance
and reliability.
Designed for use in either rack or
tower congurations, all units offer
the smallest available solutions for
these power capacities — the 5 & 6kVA
model at 120/208V output in 4U
size, or the 8 & 10kVA unit 120/208V
output in a 6U package. A 6kVA 208V
output 5U size model is also available.
To help meet the need for choosing a
single supplier for global applications,
220V, 230V and 240V 50/60 Hz
models are offered with CE and
C-tick markings.
Dual Voltages For Multiple
Applications
Simultaneous output voltages of
240/120, 208/120, 230/115, 220/110,
or 200/100 VAC provide the exibility
to adapt to multiple load requirements
without the need to add additional
transformers that take up extra space
and add weight. Input power factor
correction to 0.99 reduces current
harmonics and their heating effects.
Communications For Power
Monitoring And Control
Liebert GXT3 UPS offers a variety
of communications options to
provide the monitoring and control
capabilities demanded by today’s
network computing systems.
Operation can be monitored using:
Liebert IntelliSlot Web Card provides
SNMP and web-based monitoring
and control of your UPS.
Liebert MultiLink™ Automated
System Shutdown Software
Liebert Nform™ Monitoring System
Liebert Universal Monitor And
Remote Power Monitor Panels
Third-Party Monitoring Systems
On Line UPS
Surge
Suppression
Dynamic
Bypass
Power Factor
Correction/Rectifier
Charger
Battery
Inverter
OutputUtility
2
UPS operation and display panel can rotate
90 degrees, which provides upright
viewing for users.
Liebert® GXT3™ UPS Includes These
Outstanding Features:
Flexibility:
Rack/tower configuration. The versatile
unit installs in either conguration, and
includes a rotating LED display panel that
conforms to the desired orientation.
Automatic frequency detection. Detects
and matches line input frequencies of either
60 or 50 Hz.
User replaceable hot-swappable internal
batteries. Provide four minutes of runtime
at full load.
Additional runtime with additional
battery cabinets. UPS cabinet includes rear
panel plug-and-play connections for
optional battery cabinets. Cabinet sizes:
5-6kVA – 2U, 8-10kVA – 4U, 6kVA 208V– 3U
Liebert IntelliSlot™ communications
port. Utilizes Liebert IntelliSlot Web Card to
provide SNMP and web-based monitoring
and control of your UPS.
Includes Windows-based configuration
program. Allows various operating
parameters to be adjusted and tests to be
scheduled.
Built-in USB communications for use with
Liebert MultiLink™ Automated
Shutdown Software. Allows you to
monitor communication between the UPS
and a server, and ensures a graceful
unattended shutdown.
Built-in closure signals. Provides
notication to monitoring systems of
operating conditions including: on battery,
low battery, battery mode shutdown and
any mode shutdown.
Emergency Power Off (EPO).
Terminal connections for a normally
open or normally closed emergency
power off switch.
Higher Availability:
Wider input voltage window
minimizes battery use. Features a wide
input voltage window that allows the
UPS to support the critical load without
having to transfer to battery, extending
system availability for when battery
back-up is truly needed.
Internal automatic and manual
bypass. Assures continuity of power to
critical loads during system maintenance
or in case of internal fault.
Self-diagnostics. Automatically tests
unit electronics and batteries. Designed
to simplify maintenance and
troubleshooting.
Lowest Total Cost Of Ownership:
Standard two-year replacement
warranty. No-hassle warranty provides
paid shipping both ways. Optional
one-year and three year extensions
available.
Uses less rack space. Leaves more room
for network equipment.
For longer service life. Shields batteries
from heat generating electronic
components, enhancing battery life.
Battery cutoff voltage Automatically
adjusts based on load, extending batter y
life by preventing over-discharge of
batteries.
ENERGY STAR® qualified UPS models
UPS products
meeting the EPA’s
requirements use an
average of 35% less
energy than their
standard
counterparts.
Liebert Power Assurance
Package Offers A Worry-Free
UPS Solution For
Your Network
Liebert GXT3 5-10kVA UPS
systems may be purchased as part
of the Liebert Power Assurance
Package. While today’s smaller,
rack-based UPS systems offer
relatively trouble-free operation,
the growing criticality of the
systems they support has
increased the cost of downtime.
As a result, the need to maintain
these smaller UPS systems is
increasingly important.
This all-inclusive package offers
you complete peace-of-mind for
ve years including:
UPS — A compact, high quality
on-line Liebert GXT3 UPS (5, 6, 8
or 10kVA).
Start-up — On-site system
start-up by a certied Emerson
Network Power Customer
Engineer, scheduled anytime, 24
x 7. This includes removal and
disposal of your existing UPS.
Preventive maintenance —
One preventive maintenance
visit completed in year 3 by a
certied Emerson Network Power
Customer Engineer includes 100%
Parts Coverage — even internal
batteries.
Full parts coverage — Your
on-line Liebert UPS benets
from 100% parts coverage for
ve years, including all internal
batteries.
On-site service — Should you
experience a problem, we will
dispatch a certied Emerson
Network Power Customer
Engineer to repair or replace
your equipment — with 4-hour
response guaranteed.
3