Emerson 6 kVA, Liebert GXT2-6000RT208, Liebert GXT2-10000RT208 Brochure

Page 1
AC Power For Business-Critical Continuity
Liebert®GXT2™6 kVA & 10 kVA UPS
Rack/Tower Configurable UPS For Network Protection
168997_SL23172:15615 govern 7/22/08 2:27 PM Page 2
Page 2
2
Compact UPS Systems For High Power Network Rack Applications
Liebert GXT2 10 kVA
168997_SL23172:15615 govern 7/22/08 2:28 PM Page 3
Page 3
3
Liebert Solutions
To meet these needs for higher capacities in smaller spaces we have developed the Liebert GXT2 6 kVA and 10 kVA UPS systems. These true on-line double conversion UPS systems feature integrated maintenance bypass, as well as optional extended battery runtime. Add support — Emerson Network Power Service— and it all equals greater power assurance and reliability.
Designed for use in either rack or tower configurations, both units offer the smallest available solutions for these power capacities — the 6 kVA model at 120/208V output in 4U size, or the 10 kVA unit 120/208V output in a 6U package.
To help meet the need for choosing a single supplier for global applications, 220V, 230V and 240V 50/60 Hz models are offered with CE and C-tick markings.
On-Line UPS
Output
Utility
Inverter
Battery
Dynamic
Bypass
Surge
Suppression
Power Factor
Correction/Rectifier
Charger
Dual Voltages For Multiple Applications
Simultaneous output voltages of 240/120, 208/120, 230/115, 220/110, or 200/100 VAC provide the flexibility to adapt to multiple load requirements without the need to add additional transformers that take up extra space and add weight. Input power factor correction to
0.98 reduces current harmonics and their heating effects.
Today’s converged networks require increased availability and reliability. This has created a need
for higher density power protection systems that adapt to mixed load voltages and plug types, while
remaining easy to install and maintain.
New IT technologies, such as VoIP and PoE, have greatly increased power demands. Unfortunately, as these requirements have risen, the amount of space available for your protected equipment and related power support systems has not.
The ever-increasing global reach of businesses is also making it more advantageous to standardize on power systems that can be used in a variety of input and output configurations.
168997_SL23172:15615 govern 7/22/08 2:28 PM Page 4
Page 4
4
Liebert GXT2 6 kVA is the first true on-line UPS that combines 6 kVA of power capacity, internal batteries and dual output
voltage in a single 4U size cabinet. This makes it an ideal fit in applications where the power requirements are demanding—but
rack space is limited. Designed for use in either rack or tower configurations, the new unit is well suited for installations such as
network closets or small computer rooms.
Modular Wiring And Bypass Capability
For installation flexibility, the Liebert GXT2 6 kVA allows you to choose from several different wiring configurations made possible by the use of removable power distribution boxes that simply plug into the rear of the UPS. The standard box provides terminal blocks for hardwired input and output connections.
An optional hardwire version that includes a maintenance bypass switch is also available. When the ease of plug­and-play power connections is desired, optional versions of the power distribution box convert the Liebert GXT2 6 kVA to a cord-type input with receptacles for output distribution, as well as maintenance bypass capability.
Liebert Delivers 6 kVA Of True On-Line Power In A Compact 4U Package
User replaceable hot swappable internal batteries (front with panel removed)
Liebert GXT2 6 kVA
Easily converts to tower configuration with supplied hardware
Controls and indicators
168997_SL23172:15615 govern 7/22/08 2:28 PM Page 5
Page 5
5
Patented Feature Enhances Reliability
The Liebert GXT2 6 kVA includes a patented output neutral
bonding feature designed to comply with UL 1778, which
requires that input conductors of the UPS (including
neutral) be disconnected from the input source when the
UPS is in battery mode. The Liebert GXT2 6 kVA features a
patented circuit that maintains the UPS output neutral to
ground bond in all modes of operation, thereby eliminating
any voltage induced on the UPS output neutral connection.
Flexibility:
Rack/tower configuration — A single part number installs in either configuration.
Automatic frequency detection — The Liebert GXT2 6 kVA detects and matches line input frequencies of either 60 or 50 Hz.
Additional runtime with 2U battery cabinets — UPS cabinet
includes rear panel plug-and-play connections for optional additional battery cabinets.
IntelliSlot™communications port — Utilizes Liebert IntelliSlot Web Card to provide SNMP and web-based monitoring and control your UPS.
Includes Windows-based configuration program — Allows
various operating parameters to be adjusted and tests to be scheduled.
Built-in serial communications for use with Liebert MultiLink
Automated Shutdown Software — Allows you to monitor
communication between the UPS and a server, and ensures a graceful unattended shutdown.
Built-in closure signals — Provides notification to monitoring systems of operating conditions including: on battery, low battery, battery mode shutdown and any mode shutdown.
Emergency Power Off (EPO) — Terminal connections for a normally open or normally closed emergency power off switch.
Other Product Features Of The New Liebert GXT2 6 kVA Include:
Reliability
Wider Input Voltage Window Minimizes Battery Use — The
Liebert GXT2 6 kVA features a wide input voltage window that allows the UPS to support the critical load without having to transfer to battery, extending system availability for when battery back-up is truly needed.
Internal automatic and manual bypass — Assures continuity of
power to critical loads during system maintenance or in case of internal fault.
Self-diagnostics — Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
User-replaceable hot-swappable internal batteries — Provide five
minutes of runtime at full load.
Low Total Cost Of Ownership
Standard two-year warranty
Uses less rack space leaving more room for network equipment.
Batteries are shielded from heat generating electronic components, enhancing battery life.
Battery cutoff voltage
automatically adjusts based on load, extending battery life by preventing over-discharge of batteries.
168997_SL23172:15615 govern 7/22/08 2:28 PM Page 6
Page 6
6
A standard removable power distribution box provides flexibility when installing
the UPS. Optional power distribution boxes are available with a built-in
maintenance bypass switch that allows hot-swapping of the entire UPS.
PD-HDWR-MBS Includes bypass Input: hardwire Output: hardwire
PD-006 Includes bypass Input: L14-30 Output: (4) L5-20 (2) L6-30
PD-005 Includes bypass Input: L14-30 Output: (4) L5-20 (2) L5-30
PD-HDWR Input: hardwire Output: hardwire
PD-002 Includes bypass Input: L14-30 Output: (2) 5-15/20 (2) L6-20
PD-003 Includes bypass Input: L14-30 Outpu t: (4) 5-15/20 (2) L6-30
6 kVA Power Output Distribution Options
168997_SL23172:15615 govern 7/22/08 2:28 PM Page 7
Page 7
7
PD-004 Includes bypass Input: L14-30 Output: (4) C19
PD-001 Includes bypass Input: L14-30 Outpu t: (4) 5-15/20 (1) L6-30 (1) L14-30
Liebert GXT2 4.5 kVA and 6 kVA 230V Models
Designed for international deployment, Liebert GXT2
4.5 kVA and 6 kVA 230V models offer true on-line double conversion operation with sinewave output. Using the configuration program, the user can select output voltage in a range from 220-240V. These units only require 5U of rack space and include internal batteries and charger. Internal batteries provide approximately seven minutes of runtime at full load. Both models include an automatic and manual internal bypass. The standard configuration provides terminals for hardwired connections for the input and output, as well as two IEC320 C19 (16 amp) receptacles.
6 kVA 230V
PD-007 Includes bypass Input: L14-30 Output: (4) L6-20R
International Voltage Models
168997_SL23172:15615 govern 7/22/08 2:28 PM Page 8
Page 8
8
This Liebert GXT2 10 kVA unit is a flexible solution for protecting rack-mount equipment, including VoIP and PoE.
Especially designed for use with the new generation of high power switches, this compact UPS packs 10 kVA (8 kW) of
power into a 6U rack/tower package with flexible output voltage and optional output distribution. The UPS includes
built-in, user-replaceable batteries for up to five minutes of runtime at full load.
Adaptable Design
The new cabinet allows the on-line 10 kVA UPS to be installed in a rack for increased flexibility and functionality. The UPS has a dual inverter design, capable of providing simultaneous output voltages of 240/120, 208/120, 230/115, 220/110, or 200/100. The new 6U cabinet is the smallest for 208/120 selectable voltage in the 10 kVA size. The unit features integrated internal manual and automatic maintenance bypass, swappable power module, battery modules, auto detection of extended battery cabinets and optional plug-and-play distribution plates.
Liebert GXT2 10 kVA 208V Rack configuration
Liebert GXT2 10 kVA 208V Tower Conf igu ratio n
Front view, bezels removed — showing battery and power module
Rear view — showing built-in maintenance bypass switch
Controls and indicators
Liebert Brings You 10 kVA Of Power In Just 6U Of Space
168997_SL23172:15615 govern 7/22/08 2:28 PM Page 9
Page 9
9
Other Product Features Of The Liebert GXT2 10 kVA Include:
Low Total Cost Of Ownership
Standard two-year warranty
Uses less rack space leaving more room for network equipment.
Batteries are shielded from heat generating electronic components, enhancing battery life.
Battery cutoff voltage
automatically adjusts based on load, extending battery life by preventing over-discharge of batteries.
Reliability:
Wider Input Voltage Window Minimizes Battery Use — The Liebert
GXT2 10 kVA features a wide input voltage window that allows the UPS to support the critical load without having to transfer to battery, extending system availability for when battery back-up is truly needed.
Internal automatic and manual bypass
— Assures continuity of power to critical loads during system maintenance or in case of internal fault.
Self-diagnostics — Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
User-replaceable internal batteries — Provide five minutes of runtime at full load.
Hot-swappable operation — Unit features three bays for one power module and two battery modules. The chassis contains a bypass switch that allows all modules to be removed without powering down the connected load.
Flexibility
Rack/tower configuration — A single part number installs in either configuration.
Automatic frequency detection — The Liebert GXT2 10 kVA detects and matches line input frequencies of either 60 or 50 Hz.
Additional runtime with 4U battery cabinets — UPS cabinet includes
rear panel plug-n-play connections for optional additional battery cabinets. Use up to three cabinets for extended battery runtime applications. Contact Liebert Technical Support for longer backup time solutions.
IntelliSlot™communications port — Utilizes Liebert IntelliSlot Web Card to provide SNMP and web-based monitoring and control your UPS.
Includes Windows-based configuration program — Allows various operating
parameters to be adjusted and tests to be scheduled. This capability enables you to customize the UPS performance to your specific requirements.
Built-in serial communications for use with Liebert MultiLink
Automated
Shutdown Software — Allows you to
monitor communication between the UPS and a server, and ensures a graceful unattended shutdown.
Built-in closure signals — Provides notification to monitoring systems of operating conditions including: on battery, low battery, battery mode shutdown and any mode shutdown.
Emergency Power Off (EPO) — Terminal connections for a normally open or normally closed emergency power off switch.
Liebert GXT2 10 kVA 208V Rear view, external battery cabinet
External battery Power
module
Liebert GXT2 10 kVA 208V with external battery
168997_SL23172:15615 govern 7/22/08 2:29 PM Page 10
Page 10
10
10kVA
Liebert GXT2
UPS
10kVA
Liebert GXT2
UPS
10kVA
Liebert GXT2
UPS
PD-20X
Parallel
POD
Parallel POD
Standard Features Offer Greater Overall Value
Flexibility:
Adapts existing Liebert GXT2 10 kVA UPS to a redundant power configuration.
Power output options enable use with a wide variety of IT equipment.
Installs in a rack or on a wall.
Higher Availability:
Eliminates single point of failure when configured for redundancy.
Allows two units to be paralleled for capacity, and a third added for redundancy.
Lowest Total Cost Of Ownership:
Upgrades your existing Liebert GXT2 10 kVA UPS investment, retaining the value of your initial investment.
Saves floor space and integrates with existing rack environment.
Provides the same warranty as the UPS.
PD-201 Output: (4) 5-20R, T-type (4) L6-20R
PD-202 Output: (4) 5-20R, T-type (4) L6-30R
The Parallel POD will require start-up purchase for each GXT2-10000RT208 connected to the system.
Parallel Communication Ports
Electronic equipment may be installed at the front of the rack, with the Parallel POD installed at the back of the rack, increasing usable space.
Equipment shown from back of rack.
Input/Output Power For Paralleled UPS Units
Increase The Flexibility Of Your Liebert GXT2 10 kVA UPS: Add Capacity Or Redundancy As Your Needs Grow
Many IT managers are finding a need to increase the capacity of their rack-mounted UPS. With the Parallel POD power output distribution system, you can add capacity or redundancy at any time, without losing your investment in your Liebert GXT2 10 kVA UPS. The Parallel POD enables paralleling of two Liebert GXT2 10 kVA UPS modules to double capacity to 20 kVA. A third unit may be added to configure the system for N+1 redundancy, raising system reliability.
168997_SL23172:15615 govern 7/22/08 2:29 PM Page 11
Page 11
11
Liebert GXT2 10 kVA 230V Models
Designed for international deployment, Liebert GXT2 10 kVA 230V models offer true on-line double conversion operation with sinewave output. These units only require 5U of rack space and include internal batteries and charger. There are two unit configurations:
230V rack — Uses separate electronics module and battery module
230V tower — single unit Using the configuration program, the user can select output voltage in a range from 220-240V. Internal batteries provide approximately seven minutes of runtime at full load. The Liebert GXT2 10 kVA models include an automatic and manual internal bypass. The standard configuration provides terminals for hardwired connections for the input and output.
Optional additional battery charger for 230V tower model — where long runtime and fast recharge are required.
Liebert GXT2 10 kVA 230V
Liebert GXT2 10 kVA 230/240V Tower
A tower configuration is also available in a 230V version and a 220V version with voltage transformer.
The standard 10 kVA model includes terminal blocks for
hardwired connections of both input and output.
Optional panels are available to add output receptacles
to the rear panel of the unit.
International Voltage Models
PD-105 Output: (4) 5-20R, T-type (2) L6-30R (2) L5-20R
PD-106 Output: (4) L5-20R, (4) L6-20R
PD-102 Output: (4) 5-20R, T-type (4) L6-30R
PD-103 Output: (4) 5-20R, T-type (4) L6-30R
PD-104 Output: (4) 5-20R, T-type (2) L6-30R (2) L6-20R
PD-101 Output: (8) 5-20R, T-type (2) L6-30R
10 kVA UPS Power Output Distribution Options
168997_SL23172:15615 govern 7/22/08 2:29 PM Page 12
Page 12
12
A New View On Configuring Your UPS
Each Liebert GXT2 6 kVA
and 10 kVA system is shipped with
Windows
®
compatible software that
allows the user to program a variety of
operating parameters. This capability
allows you to customize the system’s
performance to your specific
requirements, providing a new level of
power protection control and
adaptability.
The software allows configuration of the following:
Output voltage selectable.
Enable or disable auto restart.
Select frequency converter mode:
60Hz input/50Hz output with no derating, bypass is disabled.
50 Hz input/60 Hz output with no derating, bypass is disabled.
Change the low battery warning from the standard two minutes.
Select how often you want the automatic battery test to occur.
Disable automatic battery test if necessary.
Program the UPS for the number of external battery cabinets connected, allowing the UPS to report the correct run time.
Communications For Power Monitoring And Control
The Liebert GXT2 6 kVA and 10 kVA systems offer a variety of communications options to provide the monitoring and control capabilities demanded by today's network computing systems. Operation can be monitored using:
Liebert MultiLink™ Automated System Shutdown Software
Liebert Nform™ Monitoring System
Liebert Universal Monitor And Remote Power Monitor Panels
Third-Party Monitoring Systems
Liebert IntelliSlot Web Card
Liebert IntelliSlot™ Web Card
For enhanced UPS communications and control, the Liebert IntelliSlot Web Card will deliver SNMP and web-management communications capability to a Liebert GXT2 unit. This feature will provide flexibility in how you monitor and control your UPS over the network. The card is also easily configurable to work in a standard SNMP implementation and with Liebert MultiLink shutdown software.
168997_SL23172:15615 govern 7/22/08 2:29 PM Page 13
Page 13
13
Liebert Power Assurance Package Offers A Worry-Free UPS Solution For Your Network
The Liebert GXT2 6 kVA and 10 kVA UPS systems can be purchased as part of the Liebert Power Assurance Package.
While today’s smaller, rack-based UPS systems offer relatively trouble-free operation, the growing criticality of the systems they support has increased the cost of downtime. As a result, the need to maintain these smaller UPS systems is increasingly important.
Emerson Network Power Service is your source for
start-up, maintenance warranty and maintenance
requirements of your Liebert GXT2 6 kVA and 10 kVA UPS
systems. Service and support specialists are located
everywhere you need them to be.
The Liebert Power Assurance Package is the best solution in the industry for your network power requirements. With unprecedented coverage for your small UPS systems, there is no better way to protect your business-critical network.
This all-inclusive package offers you complete peace-of-mind for five years including:
UPS — A compact, high quality on-line Liebert GXT2 6 kVA or 10 kVA UPS.
Start-Up — Onsite system start-up by a certified Service Division of Emerson Network Power Customer Engineer, scheduled anytime, 24 x 7. This includes removal and disposal of your existing UPS.
Preventive Maintenance — One preventive maintenance visit completed in year 3 by a certified Emerson Network Power Customer Service Engineer includes 100% Parts Coverage — even internal batteries.
Full Parts Coverage — Your on-line Liebert UPS benefits from 100% parts coverage for five years, including all internal batteries.
On-Site Service — Should you experience a problem, we will dispatch a certified Emerson Network Power Customer Service Engineer to repair or replace your equipment — with 4-hour response guaranteed.
With more than 300 Liebert-employed Customer Engineers in the U.S.A. and a network of over 900 factory authorized service personnel, Emerson Network Power offers critical power system support capabilities, geographical coverage and ability to respond that are second to none.
We offer 24 x 7 emergency dispatch service through our Customer Response Center. This facility provides immediate access to factory­trained technicians, located within your own area, who are quickly dispatched to your location when service is required.
Liebert Power Assurance Package
168997_SL23172:15615 govern 7/22/08 2:29 PM Page 14
Page 14
14
Specifications
Note: Part Numbers GXT2-6000RT208 and GXT2-10000RT208 do not include internal battery kits. When calculating total unit weight, add weight of internal batteries.
LIEBERT GXT2 6 KVA LIEBERT GXT2 10 KVA
Model Number GXT2-6000RT208 GXT2-10000RT208 Model Rating 4200W/5200VA at 127/220 (120 or 240 degrees) 8000W/8660VA at 127/220 (120 or 240 degrees)
4200W/5200VA at 120/208 (120 or 240 degrees) 8000W/8660VA at 120/208 (120 or 240 degrees) 4200W/6000VA at 120/240 (180 degrees) 8000W/10000VA at 120/240 (180 degrees) 4200W/6000VA at 115/230 (180 degrees) 8000W/10000VA at 115/230 (180 degrees) 3780W/5400VA at 110/220 (180 degrees) 7200W/9000VA at 110/220 (180 degrees) 3360W/4800VA at 100/200 (180 degrees) 6400W/8000VA at 100/200 (180 degrees)
DIMENSIONS Unit W x D x H in. (mm) 6.9 x 24.2 x 16.9 (176 x 615 x 430) 10.5 x 26.0 x 16.9 (267 x 660 x 430) WEIGHT lbs (kg) Unit 67 (30.3) 109 (49.3) INPUT AC PARAMETERS Nominal Operating Frequency 50 or 60 Hz (Factory Default = 60) Factory Default VAC 120/208 VAC at 120 degrees L1-L2 Factory Default Input Phase Angle 120 degrees Allowable Input Phase Angle 120, 180, 240 degrees, Auto-sensing on application of AC (Restricti ons for L-N voltages other than 120 VAC) Factory Default L1-N, L2-N VAC 120 VAC nominal Input Frequency w/o Battery Operation 40 - 70 Hz OUTPUT AC PARAMETERS Factory Default VAC 120/208 VAC @ 120 degrees L1-L2 Factory Default Output Phase Angle 120 degrees Allowable Output Phase Angle 120, 180, 240 degrees Auto-sensing on initial application of input AC Factory Default L1-N, L2-N VAC 120 VAC nominal User Configurable L1-N, L2-N VAC 100/110/115/120/127 VAC, ±3% Frequency 50 Hz or 60 Hz, Nominal Wavefo rm Sinewave Overload Rating 200% for 8 cycles; 130% for 10 seconds 200% for 8 cycles then shutdown; 130% for 60 seconds
with transfer to bypass with transfer to bypass
ENVIRONMENTAL Operating Temp +32°F to +104°F (0°C to +40°C) Storage Temp +5°F to +122°F (-15°C to +50°C) Relative Humidity 0% to 95%, non-condensing Operating Elevation Up to 10,000 ft. (3000m) at 104°F (40°C) without derating Storage Elevation 50,000 ft. (15,000 m) maximum Audible Noise <55 dBA, at 1 meter from the rear; <50 dBA, at 1 meter from the front or sides AGENC Y Safety UL 1778, c-UL Listed (Suitable for computer room applications) RFI/EMI FCC Part 15, Subpart B, Class A Surge Immunity IEEE/ANSI C62.41 Category A & B Transportation ISTA Procedure 1A
INTERNAL BATTERY Model Number GXT2-144BATKIT (one required) GXT2-288RTBKIT (two required) WEIGHT lbs (kg) 79 (35.8) (one required) 78.1 (35.5) (two required) Typ e Valve-regulated, non-spillable, flame retardant, lead acid Quantity x V x Rating 12 x 12V x 9.0 AH (one required) 12 x 12V x 9.0 AH (two required) Battery Mfg / Part # Yuasa / REW 45-12 FR Recharge T ime 6 Hours to 90% capacity after full discharge into 100% load
OPTIONAL EXTENDED BATTERY CABINET Model Number GXT2-144VBATT GXT2-288RTVBATT (requires two GXT2-288RTBKIT) DIMENSIONS W x D x H in.(mm) 3.5 x 24.2 x 16.9 (87 x 618 x 430) 7.0 x 26.0 x 16.9 (178 x 660 x 430) WEIGHT lbs (kg) Unit 93.6 (42.5) 197.8 (89.9) (Total weight with batteries) BATTERY PARAMETERS Typ e Valve-regulated, non-spillable, flame retardant, lead acid Qty x V x Rating 12 x 12V x 9.0 AH per kit 12 x 12V x 9.0 AH per kit (two required) Battery Mfg / Part # Yuasa / REW 45-12 FR ENVIRONMENTAL Operating Temp +32°F to +104°F (0°C to +40°C) Storage Temp +5°F to +122°F (-15°C to +50°C) Relative Humidity 0% to 95%, non-condensing Operating Elevation Up to 10,000 ft. (3000m) at 104°F (40°C) without derating Storage Elevation 50,000 ft. (15,000m) maximum AGENC Y Safety UL 1778, c-UL Listed (Suitable for computer room applications) RFI/EMI FCC Part 15, Subpart B, Class A Transportation ISTA Procedure 1A
168997_SL23172:15615 govern 7/22/08 2:30 PM Page 15
Page 15
15
Liebert GXT2 6 kVA 230V International Model
Liebert GXT2 10 kVA 208V
Liebert GXT2 10 kVA 230V International Model
Note: Contact your Liebert representative or www.liebert.com for more details.
* Required Paralleling Components
Total Runtime with Internal and
Extended Battery Cabinets/Full Load
POWER DISTRIBUTION GXT2-6000RT208
Model Number Amp Rating Input Power Connection Output Power Connection PD-HDWR 30 No Bypass Hardwire Terminals Hardwire Terminals PD-HDWR-MBS 30 With Bypass Hardwire Terminals Hardwire Terminals PD-001 30 With Bypass L14-30P (1) L6-30R,(1) L14-30R,
(4) 5-15/20R T-slot PD-002 30 With Bypass L14-30P (2) L6-20R, (2) 5-15/20R T-slot PD-003 30 With Bypass L14-30P (2) L6-30R,
(4) 5-15/20R T-slot PD-004 30 With Bypass L14-30P (4) EN60320 / C19 PD-005 30 With Bypass L14-30P (4) L5-20R,
(2) L5-30R PD-006 30 With Bypass L14-30P (4) L5-20R, (2) L6-30R PD-007 30 With Bypass L14-30P (4) L6-20R
GXT2-10000RT208
Model Number Amp Rating Input Power Connection Output Power Connection PD-101 50 N/A (8) 5-15/20R T-slot, (2) L6-30R PD-102 50 N/A (4) 5-15/20R T-slot, (4) L6-20R PD-103 50 N/A (4) 5-15/20R T-slot, (4) L6-30R
GXT2-PP20KRT208
Model Number Amp Rating Input Power Connection Output Power Connection PD-201 120 N/A (4) 5 - 15/20R T-slot, (4) L6-20R PD-202 120 N/A (4) 5 - 15/20R T-slot, (4) L6-30R
BATTERY CABINETS
UPS Model Runtime w/Internal Extended Battery
Batteries/Full Load Cabinet P/N Voltage One Cabinet Two Cabinets GXT2-6000RT208 5 min. GXT2-144VBATT 144 VDC 14 min. 25 min. GXT2-6000RT230 7 min. GXT2-240VBATT 240 VDC 21 min. 38 min. GXT2-4500RT230 10 min. GXT2-240VBATT 240 VDC 31 min. 54 min. GXT2-10000RT208 5 min. GXT2-288RTVBATT 288 VDC 14 min. 25 min. GXT2-10000R230 NA GXT2-240RVBATT 240 VDC 5 min. 15 min. GXT2-10000T230 5 min. GX T2-240TBATTCE 240 VDC 23 min. 43 min. GXT2-10000T220 5 min. GXT2-240TBATTUL 240 VDC 22 min. 42 min.
INTERNATIONAL MODELS
Model Input Voltage / Frequency Output Voltage / Frequency' Output Rating VA/W GXT2-6000RT230 176 - 276, 50 or 60 Hz, L-L-G 220, 230 or 240 L-L-G 6000/4200 GXT2-4500RT230 176 - 276, 50 or 60 Hz, L-L-G 220, 230 or 240 L-L-G 4500/3150 GXT2-10000R230 176 - 276, 50 or 60 Hz, L-L-G 220, 230 or 240 L-L-G 10000/7000 GXT2-10000T230 176 - 276, 50 or 60 Hz, L-L-G 220, 230 or 240 L-L-G 10000/7000 GXT2-10000T220 176 - 276, 50 or 60 Hz, L-L-G 220, 230 or 240 L-L-G 10000/7000
PARALLEL CAPABILITY GXT2-PP20KRT208
Description Paralleling POD maximum (3) GXT2-10000RT208 connection for 20kVA capacity plus 10kVA
redundancy (requires (1) paralleling cable p/n GXT2-20KPC-6 for connection to each
GXT2-10000RT208) Rating 20,000VA / 16,000W at 120/208 or 120/240 Unit Dimensions 16.94”w x 9.85”d x 16.61”h [430mm (w) x 250mm (d) x 422mm (h)] Shipping Dimensions 23.05”w x 16.74”d x 19.38”h [585mm (w) x 425mm (d) x 492mm (h)] Unit Weight 41.89lb (19kg) Shipping Weight 48.94lb (22.2kg)
PARALLEL CAPABILITY GXT2-20KPC-6
Description Paralleling cable, approximately 6 feet long
SYSTEM CONFIGURATION
Capacity / Redundancy GXT2-10000RT208 GXT2-288RTBKIT GXT2-PP20KRT208 GXT2-20KPC-6 PD-201 10kVA / 10kVA 2* 4* 1* 2* 1 20kVA / - 2* 4* 1* 2* 1 20kVA / 10kVA 3* 6* 1* 3* 1
Liebert GXT2 6 kVA 208V
168997_SL23172:15615 govern 7/22/08 2:30 PM Page 16
Page 16
Emerson Network Power. The global leader in enabling Business-Critical Continuity
.
EmersonNetworkPower.com
AC Power
Connectivity DC Power
Embedded Computing Embedded Power Monitoring
Outside Plant Power Switching & Controls
Racks & Integrated Cabinets Services
Precision Cooling
Surge Protection
Liebert Corporation
1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX
Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX
Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.)
Ensuring The High Availability Of Mission-Critical Data And Applications.
Ensuring The High Availability Of Mission-Critical Data And Applications.
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
© 2008 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
of their respective owners.
® Liebert is a registered trademark of the Liebert Corporation.
SL-23172 (07/08) Printed in USA
Emerson Network Power, the global leader in enabling business-critical continuity, ensures network resiliency and adaptability through a family of technologies — including Liebert power and cooling technologies — that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity. Enterprises benefit from greater IT system availability, operational flexibility, and reduced capital equipment and operating costs.
168997_SL23172:15615 govern 7/22/08 2:27 PM Page 1
Loading...