Emerson Fisher 1061 Data Sheet

1061 Actuator
D100095X012
Fisherr 1061 Pneumatic Piston Rotary Actuator
Fisher 1061 pneumatic piston rotary actuators are used to operate splined-shaft rotary control valves such as Vee-Ballt valves, eccentric disc valves, and butterfly valves. The actuator/valve body linkage of this actuator can be positioned for either push-down-to-open or push-down-to-close action.
Additionally, the 1061 actuator can be used with a two-position control signal for on-off service or with a valve positioner for throttling service. An optional handwheel actuator is also available to allow for auxiliary or emergency manual valve operation when the 1061 piston actuator is not in use. For complete information on the valve positioner and the manual handwheel actuator, refer to the appropriate bulletin.
Product Bulletin
61.2:1061
February 2013
Features
Application Flexibility–Actuator is available in
push-down-to-open or push-down-to-close construction and may be mounted in any of four actuator/valve body mounting positions (see figure
2).
Minimal Dead Band–Single-point linkage with
splined and clamped lever minimizes lost motion and improves control accuracy.
Compact Construction–Compared to similar
actuators, overall size is reduced by as much as 30 percent.
W8380-2
1061 Actuator with FIELDVUE™ DVC6200 Digital Valve
Controller Mounted on a Fisher V500 Valve
Long Service Life–Rugged construction provides
stability, corrosion resistance, and protection from deformation should the actuator be over-pressured.
Accessibility–Actuator/valve body linkage is
completely enclosed, yet the valve packing adjustment remains accessible without removing any parts.
Monitoring Ease–Highly visible travel indicator
allows easy determination of valve position.
www.Fisher.com
Product Bulletin
61.2:1061 February 2013
Specifications
1061 Actuator
D100095X012
Available Configuration
Actuator Sizes: J 30, J 40, J 60, J 68, J 80, J 100, and J 130
Action: Double-acting pneumatic piston rotary actuator for J throttling service when used with positioner, or J on-off service when used with switching devices
Cylinder Operating Pressure
Minimum Recommended: J 1.4 bar (20 psig) without positioner, or J 0.35 bar (5 psi) above actuator requirement with positioner
Maximum Allowable
(2)
(1)
.
Sizes 30 and 60: 6.9 bar (100 psig) Size 40: 10.3 bar (150 psig) Size 68: 5.9bar(85psig) Size 80: 10.3 bar (150 psig) Size 100: 10.3 bar (150 psig) Size 130: 10.3 bar (150 psig)
Valve Shaft Diameters, mm (Inch)
Size 30: J 12.7 (1/2), J 15.9 (5/8),J 19.1 (3/4), J 22.2 (7/8), J 25.4 (1), and J 31.8 (1-1/4) Sizes 40, 60, and 68: J 19.1 (3/4), J 22.2 (7/8), J 25.4 (1), J 31.8 (1-1/4), J 38.1 (1-1/2), J 44.5
(1-3/4), and J 50.8 (2) Sizes 80 and 100: J 44.5 (1-3/4), J 50.8 (2), and J 63.5 (2-1/2) Size 130: J 76.2 (3) and J 88.9 (3-1/2)
Maximum Valve Shaft Rotation
J 90 degrees without travel stop or J 60 degrees with optional travel stop
Maximum Breakout Torque
(1)
Size 30: Up to 282 NSm (2500 lbfSin) Size 40: Up to 847 NSm (7500 lbfSin) Size 60: Up to 1130 NSm (10,000 lbfSin) Size 68: Up to 1540 NSm (13,600 lbfSin) Size 80: Up to 5080 NSm (45,000 lbfSin) Size 100: Up to 6290 NSm (55,700 lbfSin) with 63.5 mm (2-1/2 in.) valve shaft diameter
Size 130: Up to 19,800 NSm (175,000 lbfSin)
Stroking Time
Dependent on actuator size, rotation, and positioner if used. If stroking time is critical, consult your Emerson Process Management sales office.
Construction Materials
Cylinder and Cylinder Flange: Aluminum
Housing Cover: J Cast iron or J aluminum (only for size 130)
Piston: J Aluminum or J Nylon-coated piston (optional only for sizes 30 to 100)
Piston Rod: Chrome-plated stainless steel
Lever: Ductile iron
Sliding Seal: Aluminum
O-Rings: Nitrile
Housing:
Sizes 30, 40, 60, and 68: Cast iron Sizes 80, 100 and 130: Aluminum
Mounting Yoke: Cast iron
Mounting Yoke Bushing: PTFE and steel
Material Temperature Capabilities with Standard Elastomers
(2)
-34 to 82_C(-30to180_F)
Pressure Connections
1/4 NPT internal, and for optional pipe-away vent, 3/4 NPT internal connection Size 130 uses 1 NPT internal connection. See table 1
Travel Indication
Graduated scale and pointer located on actuator end of valve shaft
Mounting Positions
Seefigure2
Approximate Weight
See table 2
1. Actual actuator torque available depends on specific construction and casing pressure. For information on torque requirements of the valve being considered, contact your Emerson Pro cess Management sales office.
2. The pressure/temperature limits inthis manual and anyapplicable standard or code limitation for actuat or should not be exceeded.
2
1061 Actua tor
D100095X012
Figure 1. Sectional of Fisher 1061 Actuator
Product Bulletin
61.2:1061
February 2013
W3827-1
W2288-3
Table 1. Displacement for 90 Degree Rotation
SIZE
30 40 60 68
80 100 130
PISTON DOWN PISTON UP
3
cm
1100 2130 4060
7210 13,000 19,100 41,100
Inch
67 130 248 440 794
1165 2508
3
3
cm
1200 2230 4380
7110 12,900 18,800 40,200
Inch
74 136 267 434 788
1150 2454
3
Table 2. Approximate Weight
ACTUATOR SIZE kg Lb
30 40 60 68
80 100 130
22 29 39
56 122 135 299
49 63
86 123 246 298 660
Options
Pneumatic Instruments: J 3710, J 3610JP, or J 3620JP pneumatic or electro-pneumatic positioners or J FIELDVUE DVC6200 Digital Valve Controllers are available. Also, the 377 Series trip valves are available with J lock-in-last position, J fail-up, or J fail-down action (for specifications, see separate bulletins).
Potentiometer: It is used for remote valv e rotation indication.
Limit Switches: J TopWorx™ DXP M21GNEB limit switch for one through six single-pole, double-throw contacts (see separate bulletin), J GOt proximity switches for one or two single-pole, double-throw contacts, or J Micro-Switches or NAMCO switches for one or two single-pole, double-throw or double-pole, double-throw contacts. GO proximity switch are not available for size 80, 100 or 130 actuators.
Handwheel Actuator: The Fisher 1078 manual declutchable actuator (see figure 3) allows auxiliary or emergency valve operation of sizes 30 through 100 when engaged (see bulletin 61.8:1078).
Cylinder Bypass: The bypass valve is required when a handwheel actuator is specified.
Locking Mechanism: The locking mechanism shown in figure 4 is available for sizes J 30, J 40, J 60, and J 68 actuators. The locking mechanism shown in figure 5 is available for sizes J 80 and J 100 actuators.
FlowScannert Connections: Optional quick disconnect connections are available for use with the portable FlowScanner microprocessor-based diagnostic testing unit.
Pipe-Away Vent: Some applications use natural gas or other hazardous gases as a supply pressure to the actuator. These applications require the actuator housingtobevented,reducingtheaccumulationof gases. For new constructions and retrofit kit information, contact your Emerson Process Management sales office with complete service conditions.