Rev. 04.23.07
DPT50-M Series
1 of 2
Embedded Power for
Business-Critical Continuity
DPT50-M Series
50 Watts
Special Features
• Medical safety approvals
• CE Mark EMC & LVD
• Universal AC input
• Fully regulated output
• Overpower and short
circuit protection
• Constant voltage
• High efficiency
• High MTBF
• IEC320 AC receptacle,
3 pin (type C14)
• Built in EMI filter
(CISPR 22 Class B)
• LED power good indicator
• Input power <74 watts
• Complies with EN61000-3-2
Total Power: 30 - 50 Watts
Input Voltage: 127 - 300 VDC
90 - 264 VAC
# of Outputs: Triple
Electrical Specifications
Safety
Input
Input ra nge 90-264 VAC (wide range) 127-300 VDC
Frequency 47-440 Hz
Inrush current <60 A peak @ 230 VAC, cold start @ 25°C
Efficiency 80% @ typical full load, @115VAC
EMI RFI
FCC Part 15, Subpart B Class B & EN55022 (CISPR22) Class B
Safety ground
leakage current
275uA @ 50/60 Hz, 264 VAC input
Output
Maximum power 50 W (DPT51-M, 30W)
Hold-up time 10 ms typical at full load @ 115VAC
Overpower protection
Output short circuit protection auto recover.
Overpower protected @ 110 - 160% above maximum rating
Overvoltage protection 20-45% above nominal output maximum
Caable/2 meter
connector
DC cable with 5 pin Din
Operating temperature:
0°C to +40°C ambient. D erate each output as 2.5% per degree
from 40° to 60°C. -20°C start up.
Storage temperature: -40°C to +85°C
Electromagnetic
susceptibility:
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity: Operating; non-condensing 10% to 95% RH
Vibration: IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions
Environmental Specifications
UL UL60601-1
CSA CSA-C22.2 NO. 601.1-M90
VDE 07501/EN60601-1 (IEC601)
CE EMC & LVD