Embedded Power for Business-Critical Continuity

DPS50

60 Watts

Total Power:

30

- 60 Watts

Input Voltage:

90

-

264 VAC

 

127

- 300 VDC

# of Outputs:

Single

Special Features

CE Mark EMC & LVD

Universal AC input

Fully regulated output

Overload and short circuit protection

Internal remote sense to the output plug

Constant voltage

High efficiency

High MTBF

IEC320 AC receptacle, 3 pin (type C14)

Built in EMI filter (CISPR 22 Class B)

LED power good indicator

Input power <74 watts

Complies with EN61000-3-2

Safety

UL

UL 60950-1

CSA

CSA-C22.2 no.60950-1

VDE

EN60950-1

CE

EMC & LVD

CB

Certificate and report

PSE

Denan 06-03051012

Rev. 09.21.06 DPS50 1 of 2

RoHS

Electrical Specifications

Input

Input range

90-264 VAC (wide range)

 

127 - 300 VDC

Frequency

47-440 Hz

Inrush current

<60A @ 230 VAC, cold start @ 25C

Input current

<2.0A rms @ 115 VAC; <1A @ 230 VAC

Efficiency

80% @ full load typical, @115VAC

EMI/RFI

FCC Part 15, Subpart B Class B & EN55022 (CISPR 22) Class B

Safety ground

0.5mA @ 50/60 Hz, 264 VAC input

leakage current

 

Output

 

Maximum Power (Po)

60W (DPS52, 30W)

Hold-up time

10ms. typical at full load @ 115VAC

Overvoltage protection

20% - 45% above nominal output maximum

 

Latching type, recycle AC to reset.

Overload protection

Output short circuit protection auto recover

 

Overload protected @ 120 - 150% above maximum rating

Cable/connector

DC cable with 2.5mm center plug

 

DC plug center +v

 

DC plug outer -v

Environmental Specifications

Operating temperature:

0° to +40°C ambient. Derate each output as 2.5% per degree

 

 

 

from 40°C to 60°C. -20°C start up

Storage temperature:

-40°C to +85°C

Electromagnetic

Designed to meet EN61000-4, -2, -3, -4, -5, -6, -8, -11, level 3

susceptibility:

 

Humidity:

Operating; non-condensing 10% to 90% RH

Vibration:

Three orthogonal axes, 3 sweeps per axe at 1 oct/min. 2G peak

8Hz to 500Hz, operational

 

 

 

MTBF demonstrated:

>550,000 hours at full load and 25°C ambient conditions

 

 

 

 

 

 

 

 