EMERSON DPT50 User Manual

0 (0)
EMERSON DPT50 User Manual

Embedded Power for Business-Critical Continuity

DPT50 Series

50 Watts

Total Power:

30

- 50 Watts

Input Voltage:

127

- 300 VDC

 

90

-

264 VAC

# of Outputs:

Triple

Special Features

CE Mark EMC & LVD

Universal AC input

Fully regulated output

Overpower and short circuit protection

Constant voltage

High efficiency

High MTBF

IEC320 AC receptacle, 3 pin (type C14)

Built in EMI filter (CISPR 22 Class B)

LED power good indicator

Input power <74 watts

Complies with EN61000-3-2

Safety

UL

UL60950-1

CSA

CSA-C22.2 NO. 60950-1

VDE

EN60950-1

CE

EMC & LVD

CB

Certificate and report

Rev. 04.23.07

DPT50 Series

1 of 2

RoHS

Electrical Specifications

Input

Input range

90-264 VAC (wide range) 127-300 VDC

Frequency

47-440 Hz

Inrush current

<60 A peak @ 230 VAC, cold start @ 25°C

Efficiency

80% @ typical full load, @115VAC

EMI RFI

FCC Part 15, Subpart B Class B & EN55022 (CISPR22) Class B

Safety ground

0.5mA @ 50/60 Hz, 264 VAC input

leakage current

 

Output

 

Maximum power

50 W (DPT51-M, 30W)

Hold-up time

10 ms typical at full load @ 115VAC

Overpower protection

Output short circuit protection auto recover.

 

Overpower protected @ 110 - 160% above maximum rating

Overvoltage protection

20-45% above nominal output maximum

Caable/2 meter

DC cable with 5 pin Din

connector

 

 

 

Environmental Specifications

Operating temperature: 0°C to +40°C ambient. Derate each output as 2.5% per degree

 

 

 

from 40° to 60°C. -20°C start up.

Storage temperature:

-40°C to +85°C

Electromagnetic

 

susceptibility:

Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3

Humidity:

Operating; non-condensing 10% to 95% RH

Vibration:

IEC68-2-6 to the levels of IEC721-3-2

MTBF demonstrated:

>550,000 hours at full load and 25°C ambient conditions

 

 

 

 

 

 

 

 

Loading...
+ 1 hidden pages