Emerson Cash Valve B Series Service Installation Instruction

CASH VALVE TYPE B 1 ¼" - 2" PRESSURE REGULATOR
OXYGEN SERVICE INSTALLATION INSTRUCTION
Before installation, these instructions must be read carefully and understood.
DESCRIPTION
The Type B pressure reducing and regulating valve automatically reduces a high inlet pressure to a lower delivery pressure and maintains the lower pressure within reasonably close limits regardless of the pressure fluctuations on the inlet side of the valve.
SPECIFICATION DATA
Service: Oxygen gas (including medical
grade oxygen)
Sizes: 1 ¼, 1 ½ and 2" (32, 38 and 51 mm) Connections: Threaded internal inlet and outlet Body Material: Bronze Temperature Rating: +150 to -320°F
(65.6 to -195.6°C)
Maximum Initial Pressure: 400 psi (27.58 bar) Capacity: For specific capacity information,
consult the factory.
GENERAL INSTALLATION INSTRUCTIONS
The Type B regulator should be installed in the horizontal position with the spring chamber upright. For other installation requirements, consult the factory. For easy operation and maintenance, it is suggested that manual shut-off valves be installed upstream and downstream from the valve. Before installing the valve, all piping should be thoroughly flushed out to remove any foreign material. Install the valve with the inlet pipe fitted to the inlet connection identified on the valve body. Use a compatible sealant on the male pipe threads and do not over tighten the valveconnections.
CONSTRUCTION
Bronze body, brass internal trim, Buna-N diaphragms and seat, Stainless steel pressurespring.
All parts are commercially cleaned for oxygenservice.
OPERATING INSTRUCTIONS
Adjusting the Delivery Pressure
The regulator’s delivery pressure setting is adjusted by turning the Adjusting Screw (2) or optional T-Handle (1) at the top of the Spring Chamber (5) after loosening the Adjusting Screw Lock Nut (3). To increase the delivery pressure, turn the adjusting screw clockwise (into the spring chamber). To decrease the delivery pressure, turn the adjusting screw counter-clockwise (out of the spring chamber). Tighten the adjusting screw lock nut after the adjustment has been made.
MAINTENANCE INSTRUCTIONS
CAUTION
Before attempting to replace any spare parts, be sure to shut off all pressure connections to the valve. With the valve closed, the system pressure could still be locked between the shut-off valve and the inlet and/or outlet sides of the regulator. Before proceeding with any valve service, be certain to relieve the pressure from both sides of the regulator.
Refer to section view for parts identification. Repair parts can easily be installed without removing the regulator from the line.
Emerson.com/FinalControl © 2018 Emerson. All rights reserved. VCIOM-10800-EN 19/06
CASH VALVE TYPE B 1 ¼" - 2" PRESSURE REGULATOR
OXYGEN SERVICE INSTALLATION INSTRUCTION
No. Control Description Construction
1 T-Handle Sub (Opt.) Steel
2 Adjusting Screw Steel
3 Lock Nut Steel
4 Name Plate Aluminum
5 Spring Chamber Bronze
6 Spring Button Steel or Iron
7 Pressure Spring Steel
8 Pressure Plate Brass
9 Diaphragm Buna-N
10 Screw Steel
11 Nut Steel
12 Pusher Post Button Brass
13 Screen SST or Monel
14 Seat Disk Buna-N
15 Cylinder Brass
16 Piston and Post Brass
17 Body Bronze
18 Gasket Fiber/Copper
19 Piston Spring SST
20 Bottom Plug Bronze
FIGURE 1
1
2
3
4
5
6
7
8
10
9
11
12
13
14
15
16
17
19
20
18
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Cash Valve is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Emerson.com/FinalControl
2
Loading...