The BXB50 Series are high power density dc-dc converters packaged in the industry standard footprint (2.40 x 2.28 x 0.50 inches) to give designers optimum choices when specifying for both new and replacement designs. Suitable for a wide range of applications in nearly any industry, the BXB50 was particularly designed with communication and distributed power applications in mind. Using Bellcore 332, the MTBF is greater than 1,400,000 hours. Aluminum baseplate technology with four threaded M3 inserts makes heatsink attachment and optimum thermal management easy. The BXB50 series are approved to IEC950 by UL, CSA and VDE.
Embedded Power for Business-Critical Continuity
BXB50 Series
Single output
Special Features
• Industry standard footprint MTBF >1.4 million hours (Bellcore 332)
• Input voltage to ETS300-132-2
• Adjustable output voltage
• No minimum load required
• Separate case ground pin
• 2:1 input range for battery powered applications
• Undervoltage lockout (UVLO)
• UL, VDE and CSA safety approvals
• Available RoHS compliant
• 2 year warranty
Total Power: 33 - 50W Input Voltage: 18 - 36VDC
36 - 75VDC
# of Outputs: Single
Safety
VDE0805/EN60950/IEC950 File No. 10401-3336-0205 Licence No. 40012035
UL60950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Rev.03.08.07
bxb50s
1 of 4
Rev.03.08.07
bxb50s
2 of 4
Embedded Power for Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Specifications
OUTPUT SPECIFICATIONS
Voltage adjustability 60% to 110%
Set point accuracy ±1.0%
Line regulation Low line to high line ±0.05%
Load regulation Full load to min. load ±0.10%
Minimum load 0%
Overshoot At turn-on and turn-off None
Undershoot None
Ripple and noise 3.3 V and 5 V 75 mV pk-pk, (5 Hz to 20 MHz) 20 mV rms (See Note 1) 12 V and 15 V 100 mV pk-pk,
30 mV rms
Temperature coefficient ±0.01%/°C
Transient response ±2.0% max. deviation (See Note 2) 170 μs recovery
to within ±1.0%
Remote sense 0.5 Vdc transmission
line drop compensation
INPUT SPECIFICATIONS
Input voltage range 24Vin nominal 18-36 Vdc
48Vin nominal 36-75 Vdc
Input current No load 100 mA max.
Remote OFF 20 mA max.
Input current (max.) 48 V models 3.5 A max. @ Io max. (See Note 4) and Vin = 0 to 75 V
Input reflected ripple (See Note 6) 5 mA pk-pk
Active low remote ON/OFF (See Note 7) Logic compatibility Open collector ref to -input ON 1.2 Vdc max. OFF Open circuit
INPUT SPECIFICATIONS CONTINUED
Undervoltage lockout 24 Vin: power up 17 V
24 Vin: power down 16 V 48 Vin: power up 34 V 48 Vin: power down 32.5 V
Start-up time Power up 20 ms (See Note 8) Remote ON/OFF 20 ms
EMC CHARACTERISTICS
Conducted emissions Bellcore 1089 Level A (See Note 3) FCC part 15 Level A
EN55022, CISPR22 Level A
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/case 1500 Vdc
Input/output 1500 Vdc Output/case 1500 Vdc
Switching frequency Fixed 500 kHz typ.
Approvals and VDE0805, EN60950, IEC950 standards (See Note 5) UL1950, CSA C22.2 No. 950
Case material Aluminum baseplate with plastic case
Material flammability UL94V-0
Weight 110 g (3.88 oz)
MTBF Bellcore 332 1,400,000 hours
MIL-HDBK-217F 580,000 hours @ 40 °C, 100% load min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating case temp. -40 °C to +100 °C
Non-operating -55 °C to +125 °C
Altitude Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration 5-500 Hz 2.4 G rms (approx.)
Rev.03.08.07
bxb50s
3 of 4
Embedded Power for Business-Critical Continuity
Specifications Contd.
Notes
1 Measured with 10 μF tantalum capacitor and 1 μF ceramic capacitor across
output.
2 di/dt = 0.1 A/1 μs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 0.75 lo
max. and 0.75 lo max. to 0.5 lo max.
3 Units should be characterised within systems. External components required. 4 Input fusing is recommended based on surge current and maximum input
current.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Simulated source impedance of 12
μH. 12 μH inductor in series with +Vin.
7 Active high remote on/off option is available (standard product is active low),
designate with the suffix ‘FHT’ e.g. BXB50-48S05FHTJ. Consult factory for further details and options.
8 Start-up into resistive load. 9 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details.
10 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative
PROTECTION
Short circuit Continuous, automatic recovery
Overvoltage Non-latching
Undervoltage Non-latching
Thermal 110 °C baseplate,
automatic recovery
TELECOM SPECIFICATION
Central office interface A ETS300-132-2
OUTPUT
INPUT
OVP
OUTPUT
OUTPUT OUTPUT
EFFICIENCY
REGULATION
MODEL
POWER
VOLTAGE VOLTAGE
CURRENT CURRENT
(TYP.)
LINE LOAD
NUMBER
(7,9,10)
(MAX.) (MIN.) (MAX.)
33 W 18-36 Vdc 4.3 Vdc 3.3 V 0 A 10 A 76% ±0.05% ±0.10% BXB50-24S3V3FLTJ
50 W 18-36 Vdc 14.5 Vdc 12 V 0 A 4.16 A 83% ±0.05% ±0.10% BXB50-24S12FLTJ
50 W 18-36 Vdc 17.5 Vdc 15 V 0 A 3.33 A 83% ±0.05% ±0.10% BXB50-24S15FLTJ
33 W 36-75 Vdc 4.3 Vdc 3.3 V 0 A 10 A 77% ±0.05% ±0.10% BXB50-48S3V3FLTJ
50 W 36-75 Vdc 6.5 Vdc 5 V 0 A 10 A 82% ±0.05% ±0.10% BXB50-48S05FLTJ
50 W 36-75 Vdc 14.5 Vdc 12 V 0 A 4.16 A 84% ±0.05% ±0.10% BXB50-48S12FLTJ
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by using the method shown.
TRIM
UP
TRIM
DOWN
8
7
6
RT1
OR
RT2
Embedded Power for Business-Critical Continuity
Rev.03.08.07
bxb50s
4 of 4
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power Integrated Cabinet Solutions Outside Plant
Precision Cooling
Site Monitoring and Services
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza 2 Wing Yip Street, Kwun Tong Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
PIN CONNECTIONS
PIN
NUMBER
FUNCTION
1+ Vin
2 Remote ON/OFF
3Case
4- Vin
5 - Vout
6 - Sense
7Trim
8 + Sense
9 + Vout
0.500 (12.69) ± 0.010 (0.25)
1.000 (25.40)
1.400 (35.56)
7 x Ø.040 (1.02) ±0.002 (0.05)
0.190 (4.83) ±0.010 (0.25)
0.400 (10.16)
VIEW SHOWN
PIN SIDE UP
1.90
(48.26)
VI(+) ON/OFF CASE VI (-)
2.28 (57.91) Max.
ALL DIMENSIONS IN INCHES (mm)
Tolerance : x.xx ±0.02in. (0.51mm) x.xxx ±0.010in. (0.254mm)
Vo(+) +SEN TRIM -SEN Vo (-)
0.190 (4.83) ± 0.010 (0.25)
0.700 (17.77)
0.400 (10.16)
1.000 (25.40)
2 x Ø.080 (2.03) ± 0.002 (0.05) 4 x M3 x 0.5 Through
2.000 (50.80)
1.400 (35.56)
0.200 (5.08) Min. Length for all Input and Output Pins
2.40 (60.96) Max.
0.500 (12.70)
Loading...