EMERSON BXB50 User Manual

The BXB50 Series are high power density dc-dc converters packaged in the industry standard footprint (2.40 x 2.28 x 0.50 inches) to give designers optimum choices when specifying for both new and replacement designs. Suitable for a wide range of applications in nearly any industry, the BXB50 was particularly designed with communication and distributed power applications in mind. Using Bellcore 332, the MTBF is greater than 1,400,000 hours. Aluminum baseplate technology with four threaded M3 inserts makes heatsink attachment and optimum thermal management easy. The BXB50 series are approved to IEC950 by UL, CSA and VDE.
Embedded Power for Business-Critical Continuity
BXB50 Series
Single output
Special Features
• Industry standard footprint MTBF >1.4 million hours (Bellcore 332)
• Input voltage to ETS300-132-2
• Adjustable output voltage
• No minimum load required
• Separate case ground pin
• 2:1 input range for battery powered applications
• Undervoltage lockout (UVLO)
• UL, VDE and CSA safety approvals
• Available RoHS compliant
• 2 year warranty
Total Power: 33 - 50W Input Voltage: 18 - 36VDC
36 - 75VDC
# of Outputs: Single
Safety
VDE0805/EN60950/IEC950 File No. 10401-3336-0205 Licence No. 40012035
UL60950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Rev.03.08.07
bxb50s
1 of 4
Rev.03.08.07
bxb50s
2 of 4
Embedded Power for Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Specifications
OUTPUT SPECIFICATIONS
Voltage adjustability 60% to 110%
Set point accuracy ±1.0%
Line regulation Low line to high line ±0.05%
Load regulation Full load to min. load ±0.10%
Minimum load 0%
Overshoot At turn-on and turn-off None
Undershoot None
Ripple and noise 3.3 V and 5 V 75 mV pk-pk, (5 Hz to 20 MHz) 20 mV rms (See Note 1) 12 V and 15 V 100 mV pk-pk,
30 mV rms
Temperature coefficient ±0.01%/°C
Transient response ±2.0% max. deviation (See Note 2) 170 μs recovery
to within ±1.0%
Remote sense 0.5 Vdc transmission
line drop compensation
INPUT SPECIFICATIONS
Input voltage range 24Vin nominal 18-36 Vdc
48Vin nominal 36-75 Vdc
Input current No load 100 mA max.
Remote OFF 20 mA max.
Input current (max.) 48 V models 3.5 A max. @ Io max. (See Note 4) and Vin = 0 to 75 V
Input reflected ripple (See Note 6) 5 mA pk-pk
Active low remote ON/OFF (See Note 7) Logic compatibility Open collector ref to -input ON 1.2 Vdc max. OFF Open circuit
INPUT SPECIFICATIONS CONTINUED
Undervoltage lockout 24 Vin: power up 17 V
24 Vin: power down 16 V 48 Vin: power up 34 V 48 Vin: power down 32.5 V
Start-up time Power up 20 ms (See Note 8) Remote ON/OFF 20 ms
EMC CHARACTERISTICS
Conducted emissions Bellcore 1089 Level A (See Note 3) FCC part 15 Level A
EN55022, CISPR22 Level A
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/case 1500 Vdc
Input/output 1500 Vdc Output/case 1500 Vdc
Switching frequency Fixed 500 kHz typ.
Approvals and VDE0805, EN60950, IEC950 standards (See Note 5) UL1950, CSA C22.2 No. 950
Case material Aluminum baseplate with plastic case
Material flammability UL94V-0
Weight 110 g (3.88 oz)
MTBF Bellcore 332 1,400,000 hours
MIL-HDBK-217F 580,000 hours @ 40 °C, 100% load min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating case temp. -40 °C to +100 °C
Non-operating -55 °C to +125 °C
Altitude Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration 5-500 Hz 2.4 G rms (approx.)
Loading...