AD10048P3L-001
100 Watts
Special Features
• Active power factor correction
• EN6100-3-2 compliant
• CE Mark EMC & LVD
• Universal ac input
• Fully regulated output
• Overcurrent, overvoltage
and thermal protection
• Constant voltage
• High efficiency
• High MTBF
• IEC320 ac receptacle,3 pin
(type C6)
• Built in EMI filter
• (CISPR 22 Class B)
• AC Input fuse
• Complies with One Watt Input
Energy Star / Blue Angel
requirement
Total Power: 100 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Single
Electrical Specifications
Safety
Input
Input ra nge: 90-264 Vac (wide range)
Frequency: 47-63Hz
Inrush current: 40 A maximum @ 264VAC, cold start 25 °C
Input current: 1.8 A maximum
Efficiency: 90% typical
EMI/RFI: FCC Part 15, Subpart B Class B & EN55022 (CISPR 22) Class-B
Safety ground
leakage current:
3.5 mA maximum @ 50/60 Hz, 264 VAC input
Output
Maximum Power (Po): 100 W
Hold-up time: 10 ms. minimum at full load @ 115 Vac
Overvoltage protection: 53 - 60 V
Latching type, recycle ac to reset
Overcurrent protection: Output short circuit protection auto recover
Overload protection @ 110 - 120% above maximum rating
Thermal protection: 105 °C to 120°C Trip point; output will latch off
Cable/connector: DC cable length 2.5 mm center plug
DC plug center +v
DC plug outer -v
UL: UL 60950-1
CSA: CSA-C22.2 no.60950-1
NEMKO: EN/IEC60950-1
CB: Certificate and report
Operating temperature: 0 ° to + 45 °C ambient
Storage temperature: - 40 °C to + 70 °C
Electromagnetic
susceptibility:
Designed to meet EN61000-4-2, -4, -5, level 4;
EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3
and EN61000-3-2 Class A
Humidity: Operating; non-condensing 5% to 90% RH
MTBF demonstrated: >300,000 hours at full load and 25 °C ambient conditions
Environmental Specifications
RoHS
Rev. 01.29.08
AD10048P3L-001
2 of 2
Embedded Power for
Business-Critical Continuity
Mechanical Drawing
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
Maximum
Load
Peak Load1Regulation
2
Ripple
P/P (PARD)
3
AD10048P3L-001
100 W 48 Vdc 2.08 A 2.29 A ±5% <500 mV
1. Peak current lasting <4 seconds with a maximum 10% duty cycle.
2. At 25 ºC including initial tolerance, line voltage, load currents and output voltages adjusted to factory
settings.
3. Peak-to-peak with 20MHz bandwidth and 10μF (tantalum capacitor) in parallel with a 0.1 μF capacitor at rated
line voltage and load ranges.
1.47" (H) x 2.56" (W) x 6.14" (L)
37.2mm (H) x 65.0 mm (W) x 156.0mm (L)
AC Input Connector: IEC320, C6
AC Input power cord sold separately
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is
± 0.02" (±0.5mm)
3. Warranty: 2 year
4. Weight: 1.11 lb./ 0.5 kg
5. AC input power cord sold separately.
6. Specifications at factory settings at 115 Vac input,
25 °C unless otherwise stated
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
EmersonNetworkPower. com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 (760) 930 4600
Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
EARTH
″
59
(1500)
1.46″
(37.2)
LIVE
2.56″
(65.0)
NEUTRAL
6.14″
(156.0)