EMERSON AD10048P3L User Manual

Rev. 01.29.08
AD10048P3L-001
1 of 2
Embedded Power for Business-Critical Continuity
AD10048P3L-001
100 Watts
Special Features
• EN6100-3-2 compliant
• CE Mark EMC & LVD
• Universal ac input
• Fully regulated output
• Overcurrent, overvoltage and thermal protection
• Constant voltage
• High efficiency
• High MTBF
• IEC320 ac receptacle,3 pin (type C6)
• Built in EMI filter
• (CISPR 22 Class B)
• AC Input fuse
• Complies with One Watt Input Energy Star / Blue Angel requirement
Total Power: 100 Watts Input Voltage: 90 - 264 Vac # of Outputs: Single
Electrical Specifications
Safety
Input
Input ra nge: 90-264 Vac (wide range) Frequency: 47-63Hz Inrush current: 40 A maximum @ 264VAC, cold start 25 °C Input current: 1.8 A maximum Efficiency: 90% typical EMI/RFI: FCC Part 15, Subpart B Class B & EN55022 (CISPR 22) Class-B Safety ground
leakage current:
3.5 mA maximum @ 50/60 Hz, 264 VAC input
Output
Maximum Power (Po): 100 W Hold-up time: 10 ms. minimum at full load @ 115 Vac Overvoltage protection: 53 - 60 V
Latching type, recycle ac to reset
Overcurrent protection: Output short circuit protection auto recover
Overload protection @ 110 - 120% above maximum rating
Thermal protection: 105 °C to 120°C Trip point; output will latch off
Cable/connector: DC cable length 2.5 mm center plug
DC plug center +v DC plug outer -v
UL: UL 60950-1 CSA: CSA-C22.2 no.60950-1 NEMKO: EN/IEC60950-1 CB: Certificate and report
Operating temperature: 0 ° to + 45 °C ambient Storage temperature: - 40 °C to + 70 °C Electromagnetic
susceptibility:
Designed to meet EN61000-4-2, -4, -5, level 4; EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3 and EN61000-3-2 Class A
Humidity: Operating; non-condensing 5% to 90% RH MTBF demonstrated: >300,000 hours at full load and 25 °C ambient conditions
Environmental Specifications
RoHS
Rev. 01.29.08
AD10048P3L-001
2 of 2
Embedded Power for Business-Critical Continuity
Mechanical Drawing
Ordering Information
Model
Number
Maximum
Power
Output
Voltage
Maximum
Load
Peak Load1Regulation
2
Ripple
P/P (PARD)
3
AD10048P3L-001
100 W 48 Vdc 2.08 A 2.29 A ±5% <500 mV
1. Peak current lasting <4 seconds with a maximum 10% duty cycle.
2. At 25 ºC including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20MHz bandwidth and 10μF (tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
1.47" (H) x 2.56" (W) x 6.14" (L)
37.2mm (H) x 65.0 mm (W) x 156.0mm (L) AC Input Connector: IEC320, C6 AC Input power cord sold separately
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is
± 0.02" (±0.5mm)
3. Warranty: 2 year
4. Weight: 1.11 lb./ 0.5 kg
5. AC input power cord sold separately.
6. Specifications at factory settings at 115 Vac input, 25 °C unless otherwise stated
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
EmersonNetworkPower. com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls Precision Cooling Racks & Integrated Cabinets
Services
Surge Protection
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling business-critical continuity.
AC Power
Connectivity
DC Power
EARTH
59
(1500)
1.46″
(37.2)
LIVE
2.56″
(65.0)
NEUTRAL
6.14″
(156.0)
Loading...